11
© 2019 Antari Lighting and Effects Ltd.
www.antari.com
․
Only use a damp cloth to clean the casing.
․
Before storing run distilled water through the system to help avoid condensing the
pump or heater.
․
It is recommended to run the machine on a monthly basis in order to achieve best
performance and output condition.
․
Excessive dust, liquid and dirt built up will degrade performance and cause
overheating.
Fuse Replacement
Disconnect AC power before replacing the fuse. Only replace the fuse with
same type and rating.
Step 1: Disconnect the power cord from the supply.
Step 2: Use a flat-head screwdriver to release the fuse holder.
Step 3: Replace the fuse with exact same type and rating as indicated below.
Step 4: Reinsert fuse holder.
Fuse
120V = T10A 250V
240V = T7A 250V
Error Messages
Indicates heater exceeds temperature range
Overheat
Error