8
Maintenance
The HZ-400 hazer requires almost no maintenance. However, you should keep the unit clean. Disconnect
the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in liquid.
Please clean internal components once a year with a light brush and vacuum cleaner. Do not use alcohol or
solvents.
Keep connections clean. Disconnect electric power, and then wipe the connections with a damp cloth. Make
sure connections are thoroughly dry before linking equipment or supplying electric power.
Do not allow the hazer liquid to become contaminated. Always replace the caps on the hazer liquid
container and the hazer machine liquid tank immediately after filling.
After every 40 hours of continuous operation, it is recommended to run a cleaning solution composed of
80% distilled water/20% white vinegar through the system.
When cleaning, use only a clean, lint-free soft cloth. An effective cleaning regimen is as follows:
1.
While unit is unplugged and cool, unscrew nozzle at very front of unit and clean out debris with vinegar
and a pipe cleaner, making sure that the hole is free of clogs.
2.
Empty all hazer fluid from machine. Add cleaning solution to tank. Plug unit.
3.
Run unit in a well-ventilated area until tank is empty
.
4.
Cleaning is ready. Refill with liquid.
Performance Notes
All hazer machines develop little drops of hazer fluid around the output nozzle. Because this may result
in some moisture accumulation on the surface below the output nozzle, consider this condensation when
installing your unit.
Troubleshooting
Antari HZ-400 Hazer
This troubleshooting guide is meant to help solve simple problems.
Always monitor tank fluid level as you are fogging. Running a hazer machine with no fluid can permanently
damage the unit.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit operates
properly, do not carry out following steps.
If the hazer does not operate properly, refer servicing to a technician.
1.
If you experience low output, pump noise or no output at all, unplug immediately.
2.
Check fluid level, the external fuse, remote connection, and power from the wall.
3.
If all of the above appears to be O.K., plug the unit in again.
4.
If fog does not come out after holding the remote button down for 30 seconds, check the hose attached to
the tank to make sure there is fluid going through the hose. Make sure the fogger isn’t warming up.
5.
If you are unable to determine the cause of the problem, do not simply continue pushing the remote
button, as this may damage the unit.
6.
Return the machine to your Antari dealer.