Antari HZ-1000 User Manual Download Page 8

Pin 

Function 

Ground 

Data- 

Data+ 

Not used 

Not used 

 

DMX Operation 

Making the DMX Connection 

– Connect machine to a DMX controller or to one of the 

machines in the DMX chain. The machine uses 3-pin and 5-pin XLR connectors for DMX 

connection, the connector is located on the rear of the machine. 

 

 

DMX Channel Function 

Channel 1 

DMX Value Range 

Function 

Haze Output Level 

– 5 

Haze Off 

– 127 

Haze Output Low 

 

128-255 

Haze Output High 

Channel 2 

DMX Value Range 

Function 

Fan Output Level 

– 5 

Fan 20% 

– 255 

Fan 21 

– 100% 

 

Fluid 

 

Only use Antari HZL oil-based liquid for the HZ-1000 Hazer. The machine is tested and 

calibrated with this liquid to get the best output performance. Warranty will be voided if any 

other type of liquid is used, improper use of liquid may lead to machine failure and 

malfunction. 

Summary of Contents for HZ-1000

Page 1: ...1 HZ 1000 Hazer Machine User Manual English 2018 Antari Lighting and Effects Ltd...

Page 2: ......

Page 3: ...wer before servicing and when not in use This product is for indoor use only Do not expose to rain or moisture If fluid is spilled disconnect AC power and clean with a damp cloth If fluid is spilled o...

Page 4: ...medical advice Unpacking and Inspection Immediately upon receiving the machine carefully unpack the carton check all content to ensure that all parts are present and have been received in good conditi...

Page 5: ...50 cm of open space around the machine Step 2 Fill the fluid tank with Antari approved fluid WDMX Wireless Solution Optional TFT Color Touch Panel Breaker Main Power Switch XLR 3 Pin 5 Pin in out DMX...

Page 6: ...erly grounded to avoid risk of electrocution Step 4 To start making haze press VOLUME on screen then select output level LOW or HIGH To stop making haze press OFF Step 5 To turn off the machine put th...

Page 7: ...01 secs 59 mins 59 secs LOW HIGH LOW HIGH 20 100 001 511 Power On Off Reset On Off On Off On Off DMX Connector Pin Assignment The machine provides 3 or 5 pin XLR connectors for DMX connection The dia...

Page 8: ...e DMX Channel Function Channel 1 DMX Value Range Function Haze Output Level 0 5 Haze Off 6 127 Haze Output Low 128 255 Haze Output High Channel 2 DMX Value Range Function Fan Output Level 0 5 Fan 20 6...

Page 9: ...t condition Excessive dust liquid and dirt built up will degrade performance and cause overheating Breaker Reset Disconnect AC power before replacing fuse Only replace fuse with same type and rating S...

Page 10: ...capacity 6 4 l 1 69 gal Compatible fluid Antari HZL Haze Fluid Operating time 40 hrs max output Ambient temp range 0 C 40 C 32 F 104 F Output 7500 cu ft min 212 m min Control DMX 512 Timer Manual Wire...

Page 11: ......

Page 12: ...12 C08HZ1001...