8
Pin
Function
1
Ground
2
Data-
3
Data+
4
Not used
5
Not used
DMX Operation
Making the DMX Connection
– Connect machine to a DMX controller or to one of the
machines in the DMX chain. The machine uses 3-pin and 5-pin XLR connectors for DMX
connection, the connector is located on the rear of the machine.
DMX Channel Function
Channel 1
DMX Value Range
Function
Haze Output Level
0
– 5
Haze Off
6
– 127
Haze Output Low
128-255
Haze Output High
Channel 2
DMX Value Range
Function
Fan Output Level
0
– 5
Fan 20%
6
– 255
Fan 21
– 100%
Fluid
Only use Antari HZL oil-based liquid for the HZ-1000 Hazer. The machine is tested and
calibrated with this liquid to get the best output performance. Warranty will be voided if any
other type of liquid is used, improper use of liquid may lead to machine failure and
malfunction.