background image

PCI Multi-port Serial Card

 

 

 

3

 

 

 

2.

 

S1~S4 Termination Resistor Enable/Disable Jumpers (JP3~6): 

 
 
Terminator Settings (JP3 for S1, JP4 for S2, JP5 for S3, JP6 for S4): 

Jumper Name 

Jumper Settings 

Termination Resistor Setting 

S1 TERM 

(S2 TERM) 
(S3 TERM) 
(S4 TERM) 

IN 

TXD (DATA- and DATA+) 
Termination Resistor Enabled 

OUT 

(Default) 

TXD (DATA- and DATA+) 
Termination Resistor Disabled 

Note:    IN :   

Jumper Installed 

 

  OUT :    Jumper Not Installed 

 

3.

 

JP2: UART Input Clock Speed Selector

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

RS-485 TXD Termination Resistor 

Enable/Disable 

UART Input Clock Speed = 14.7456MHZ, 

the maximum baud rate is 926.1Kbps. 

(Default

HI 

LO 

UART Input Clock Speed = 1.8432MHZ, 

the maximum baud rate is 115.2Kbps. 

 

HI 

LO 

Summary of Contents for MSC-104B

Page 1: ... byte on chip FIFO Up to 921 6 Kbps baud rate over 700 Kbps data throughput Precise RS485 ATTATM Auto Transceiver Turn Around feature to disable the line driver by hardware Optional 15KV ESD surge and optical isolation protection models are available Supports Windows 98SE 2000 and XP 2003 Vista MSC 104B MSC 104B SI Installation Guide 1 Introduction 2 Connector and Jumper Layout Termination Resiste...

Page 2: ...5 422 4 wire RS 422 mode 485 Default 2 wire RS 485 mode S1L S1H S1L Default Reserved for Future Use Please do NOT change it NO ECHO ECHO NO ECHO Default No echo data ECHO Transmitting data will be echoed back S2L S2H S2L Default Reserved for Future Use Please do NOT change it Please note that if the mode were set at 422 mode the ECHO settings will take no effect The Echo mode is useful for the app...

Page 3: ...ERM S3 TERM S4 TERM IN TXD DATA and DATA Termination Resistor Enabled OUT Default TXD DATA and DATA Termination Resistor Disabled Note IN Jumper Installed OUT Jumper Not Installed 3 JP2 UART Input Clock Speed Selector RS 485 TXD Termination Resistor Enable Disable UART Input Clock Speed 14 7456MHZ the maximum baud rate is 926 1Kbps Default HI LO UART Input Clock Speed 1 8432MHZ the maximum baud ra...

Page 4: ...ZIP format e g V6515_RS422_485 ZIP Please copy the file to your hard drive C or what folder you want unzip it before proceeding with your installations We assumed you copy the file to your hard drive C root directory and the unzipped folder is V6515_RS422_485 Please do NOT use the drivers in its parent directory E IO OXFORD since they are used for RS232 instead of RS422 485 4 Driver Installation f...

Page 5: ...t will cause problems because the INF files will be conflict in this case Instead please browse to the correct location folder manually to make sure the correct drivers are chosen and installed correctly The Zip file is shipped in this folder Drivers for different OS are unzipped to different folders ...

Reviews: