background image

2-Port RS422/485  Serial PCI Card 

 

 

 

7

 

 

 

 

DB9-Male Pin Assignment: 

 

 

 

 

 

 

RS422 Cable Wiring:   

 

 

 

 

RS485 (2-wire) Cable Wiring:   

 

 

 

 

 

 
Power requirements:   

5V DC, 450mA (max) 

Operating temp.: 

0 to 55

°

C (32 to 131

°

F

Operating humidity: 

5 to 95% RH 

 

8. Environmental Specifications 

DB9 (RS422 to USB Cable) 

  1 TXD- 
  2 TXD+ 
  3 RXD+ 
  4 RXD- 
  5 GND 

   

(RS422 Device) 

  1 TXD- 
  2 TXD+ 
  3 RXD+ 
  4 RXD- 
  5 GND 

   

NC = No connection

 

1            5 

6           9 

9 Pins   Signal 

  1       TXD- (DATA-) 
  2       TXD+  (DATA+) 
  3       RXD+ 
  4       RXD- 
  5       GND 
  6       NC 
  7       NC 
  8       NC 
  9       NC 

DB9 (485 to USB Cable) 

  1 DATA- 
  2 DATA+ 
  3 NC 
  4 NC 
  5 GND 

   

(RS485 Device) 

  1 DATA- 
  2 DATA+ 
  3 NC 
  4 NC 
  5 GND 

   

Summary of Contents for MSC-102B1

Page 1: ...set at any mode RS485 2 wire RS485 4 wire and RS422 and operate simultaneously There is an optional model supports Isolation and ESD protection feature It provides an ideal solution for most critical applications Features 2 Port R422 485 Serial PCI Card Installation Guide 1 Introduction 2 Connector Layout J3 S1 J4 S2 JP5 S1 Mode Selector JP1 JP3 S1 RS485 TXD Control J1 Factory Use Only JP7 S1 Term...

Page 2: ...d 15KV ESD Protection Supports Win98 Me XP CE Win2K 2003 Vista and Win 7 There are 2 sets of the jumpers to set the settings for port 1 S1 and port 2 S2 respectively Mode Selection Jumper JP5 for S1 JP6 for S2 Termination Resistor Enable Disable Jumper JP7 for S1 JP8 for S2 Echo or No Echo Selection Jumper JP3 for S1 JP4 for S2 TXD Control Selection Jumper JP1 for S1 JP2 for S2 1 Mode Settings JP5...

Page 3: ...ination Resistor Enabled 3 Echo or No Echo Settings This jumper is to set the transmission data will be echoed back or not The Echo mode is useful for the application program to detect if the RS485 bus has collision If the echoed data was not equal to the transmitted data then the bus was in a collision This setting only affects the RS485 2 wire mode It doesn t affect RS485 4 wire RS422 and RS232 ...

Page 4: ... are selectable one is MAN manually the other one is AUT automatically factor default please keep it at AUT in all cases JP1 for S1 JP2 for S2 Description TXD Control is Automatic Default TXD Control is Manual Needs to be Configured Manually in the Device Manager 5 Factory Use Only Connectors J1 This connector is only used for factory production purpose please don t install any jumper or cable on ...

Page 5: ...on slot and attached the I O card bracket to the computer chassis screw 6 Put the chassis cover back on the computer 7 Turn ON the power of your computer and peripherals 8 Proceed with Software Driver Installation NOTE PLEASE DO NOT LET WINDOWS AUTO SEARCH THE DRIVERS ON THE CD it will cause problems because the INF files will be conflict in this case Instead please browse to the correct location ...

Page 6: ... to continue select Install from a list or specific location Advanced and click Next 2 Select Include this location in the search then click Browse to specify the driver s location for your OS for example XP is E IO OXFORD XP32 and click Next to continue 3 Click Next to continue and click Finish to complete the installation 4 To check the Installation right click on My Computer and choose Manage C...

Page 7: ...C 32 to 131 F Operating humidity 5 to 95 RH 8 Environmental Specifications DB9 RS422 to USB Cable 1 TXD 2 TXD 3 RXD 4 RXD 5 GND RS422 Device 1 TXD 2 TXD 3 RXD 4 RXD 5 GND NC No connection 1 5 6 9 9 Pins Signal 1 TXD DATA 2 TXD DATA 3 RXD 4 RXD 5 GND 6 NC 7 NC 8 NC 9 NC DB9 485 to USB Cable 1 DATA 2 DATA 3 NC 4 NC 5 GND RS485 Device 1 DATA 2 DATA 3 NC 4 NC 5 GND ...

Reviews: