Antaira Technologies - Industrial Ethernet Switches
LNX-C800 Series - Hardware Manual - v2.0
Figure 2.5 - Power Terminal Block
Caution:
Only use copper conductors, 125°C, tighten to 5 lbs.
The wire gauge for the terminal block should range between 18~20 AWG.
Attention:
Utilisez uniquement des conducteurs en cuivre, 125°C, serrez à 5 lb.
Le calibre des fils du bornier doit être compris entre 18 et 20 AWG.
2.8 Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of the terminal block connector as the picture shows below in
Figure 2.6. By inserting the wires, it will detect the fault status including power failure or port link failure
(managed industrial switch only) and form a normal open circuit. An example is shown below in Figure
2.6.
Figure 2.6 - Wiring the Fault Alarm Contact
7