background image

Antaira Technologies - Industrial Ethernet Switches 

LNX-C500G Series User Manual V1.1 

 

iii 

 

FCC Notice 

This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 

15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause 

harmful interference to radio communications if the equipment is not installed and used in accordance with the 

instructions. However, there is no guarantee that interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following 

measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

Caution: Any changes or modifications not expressly approved by the grantee of this device could void the user's 

authority to operate the equipment. 

 

 

CE Mark Warning 

This is a Class-A product. In a domestic environment this product may cause radio interference in which case the 

user may be required to take adequate measures. 

 

 

 

 

Industrial Ethernet Switches 

Industrial Grade Unmanaged Ethernet Switches 

 

User Manual 

Version 1.1 (March 2018)   

 

This manual supports the following models: 

 

LNX-C500G 

 

LNX-C500G-T 

 

This document is the current official release manual. Please check our website (

www.antaira.com

) for any 

updated manual or contact us by e-mail (

[email protected]

). 

Summary of Contents for LNX-C500G Series

Page 1: ...logies Industrial Ethernet Switches LNX C500G Series User Manual V1 1 i LNX C500G Series 5 Port Industrial Compact Gigabit Unmanaged Ethernet Switches with 5 10 100 1000Tx 12 48VDC Power Input Version 1 1 User Manual ...

Page 2: ... Notice Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability a...

Page 3: ...raged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expr...

Page 4: ... Safety Precaution 2 2 Hardware Description 3 2 1 Physical Dimensions 3 2 2 Front Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Ethernet Ports 5 2 6 Cabling 7 2 7 Wiring the Power Inputs 7 3 Mounting Installation 8 3 1 DIN Rail Mounting 8 3 2 Wall Mounting 9 4 Hardware Installation 10 4 1 Installation Steps 10 5 Trouble Shooting 11 7 Technical Specifications 12 ...

Page 5: ...The LNX C500G product series supports DIN rail as well as wall mountable orientations and provides operating temperature range models in STD 10 C to 70 C and EOT 40 C to 75 C This is an industrial grade unit applicable for networking applications in factory automation ITS power utility water wastewater treatment plants and any other application that needs a compact solution 1 1 Key Features System...

Page 6: ...tch with 5 10 100 1000Tx 2 Wall mounting brackets and screws 1 DC cable 18 AWG DC jack 5 5x2 1mm 1 3 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual ...

Page 7: ...e Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies LNX C500G series 5 port compact industrial gigabit unmanaged Ethernet switch with 5 10 100 1000Tx RJ45 ports W x D x H is 26mm x 75mm x 95mm Figure 2 1 LNX C500G Series Physical Dimensions ...

Page 8: ... 2 2 3 Top View Figure 2 3 below shows the top panel of the LNX C500G series switch that is equipped with one 4 pin removal terminal block connector for dual DC power inputs 12 48 VDC Figure 2 2 Front Panel of the LNX C500G Series Figure 2 3 Top Panel View of LNX C500G Series 4 pin removal terminal block power input Grounding screw LED for PWR LAN Port 1 5 10 100 1000Tx LED for 1000Tx data transmi...

Page 9: ...network LAN Port 1 5 Right LED Green On Connected to network 10Mbps 100Mbps Flashing Networking is active Off Not connected to network 2 5 Ethernet Ports RJ 45 Ports RJ 45 Ports Auto MDI MDIX The RJ 45 ports LAN 1 5 are auto sensing for 10 100 1000Base T or 100Base Tx devices connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing the straight ...

Page 10: ...ght through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 shows the 10BASE T 100BASE TX 1000BASE T MDI port pin outs The following figures show the cabling schematics for straight through and crossover cables Pin MDI X Signal Name MDI Signal Name 1 Receive data plus RD Transmit data plus TD 2 Receive data minus RD Transmit data minus TD 3 Transmit data plus TD Receive...

Page 11: ...ner switch hub workstation etc must be less than 100 meters 328 ft long Note Cable size should be between 18 20 AWG and the torque should be tightened to 5lbs 2 7 Wiring the Power Inputs Please follow the below steps to insert the power wire 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 6 2 Tighten th...

Page 12: ... To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 5 Check if the bracket is mounted tightly on the rail 6 To remove the industrial Ethernet switch from the rail do t...

Page 13: ... industrial Ethernet switch by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall 5 To remove the wall mount bracket do the opposite from...

Page 14: ...r wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on For the help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication 5 Prepare the twiste...

Page 15: ...100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist o Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose powe...

Page 16: ...ator Per unit Power1 Green Power2 Green Fault Red Per port Link Activity Green Network Cable 10BaseT 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100BaseTX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseTX UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Mechanical Characteristics Housing Metal IP30 protection Dimension 26 x 95 x 75 mm Weight Unit Weight 1 0 lbs Shipping Wei...