background image

Antaira Technologies - Industrial Ethernet Switches 

LMX-0800G Series Hardware Manual V1.2 

 

 

 

2.4 LED Indicators 

There are LED light indicators located on the front panel of the industrial Ethernet switch that 

display the power status and network status. Each LED indicator has a different color and has 

its own specific meaning, see below in Table 2.1

 

LED 

Color 

Description 

 

P1 

 

Green 

On 

Power input 1 is active 

Off 

Power input 1 is inactive 

 

P2 

 

Green 

On 

Power input 2 is active 

Off 

Power input 2 is inactive 

 

Fault 

 

Green/ 
Red 

Green 

Power input 1 or 2 is inactive 

 

Red 

An applied alarm (such as port disconnect) has been 
triggered 

Off 

Power input 1 and 2 are both functional, and no 
active/port alarm is detecting errors 

 

Owner 

 

Green 

On 

ERPS Owner Mode (Ring Master) is ready 

Off 

ERPS Owner Mode is not active 

 

Ring 

 

Green 

On 

Ring Network is active 

Off 

Ring Network is not active 

 

LAN Port 1 ~ 8 

(Left LED) 

Green 

 

 

On 

Connected to network, 1000Mbps 

Flashing  Networking is active 

Off 

Not connected to network 

 

LAN Port 1~ 8 

(Right LED) 

Green 

 

 

On 

Networking is active, 100/10Mbps 

Flashing 

Networking is active 

Off 

Not connected to network 

Table 2.1 - LED Indicators for LMX-0800G Series 

 Caution: "P1" is the abbreviation for "Power ", “P2” is for “Power 2”, “LNK” is for “Link”, and "ACT" 

is for "Activity". 

 

2.5 Reset Button 

There is a Reset button located on the front panel of the industrial Ethernet switch that helps 

users to reboot, restore default, or save running configurations by pressing the button for different 

seconds. Please refer to Table 2.2 for the timing and function. 

 

 

Summary of Contents for LMX-0800G Series

Page 1: ... Technologies Industrial Ethernet Switches LMX 0800G Series User Manual V1 0 i LMX 0800G Series 8 Port Industrial Gigabit Managed Ethernet Switch with 8 10 100 1000Tx Ethernet Ports Version 1 2 Hardware Manual ...

Page 2: ...s Notice Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability ...

Page 3: ...ed to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not express...

Page 4: ...recaution 3 2 Hardware Description 4 2 1 Physical Dimensions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 7 2 5 Reset Button 7 2 6 Ethernet Ports 8 2 7 Cabling 9 2 8 Wiring the Power Inputs 10 2 9 Wiring the Fault Alarm Contact 10 2 10 Grounding Note 11 3 Mounting Installation 12 3 1 DIN Rail Mounting 12 3 2 Wall Mounting 13 4 Hardware Installation 14 4 1 Installation Steps 14 4 2 Mainten...

Page 5: ...h protocol that has a 50ms network recovery time The advanced network filtering and security functions such as IGMP VLAN QoS SNMP RMON Modbus TCP and 802 1X HTTPS SSH SSL increase determinism and improve network management for remote SCADA systems or control networks The LMX 0800G series is a compact IP30 rated and DIN rail or wall mountable There are also two different models for varying operatin...

Page 6: ...tem Interface and Performance All RJ 45 ports support Auto MDI MDI X Function Embedded 8 10 100 1000Tx Gigabit RJ45 Ports Store and forward switching architecture 8K MAC address table Power line EFT protection 2 000VDC Ethernet ESD protection 6 000VDC Power Input DC 12 48V redundant with a 6 pin removal terminal block One user programmable alarm relay contact The power input specification is compl...

Page 7: ...ion If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual Warning Labels The caution label means that you should check the certain information on user manual when working with the device Shown in Figure 1...

Page 8: ...ardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMX 0800G series 8 port industrial gigabit managed Ethernet switches with 8 10 100 1000Tx RJ45 Ethernet ports W x D x H is 54mm x 99mm x 142mm Figure 2 1 LMX 0800G Series Physical Dimensions ...

Page 9: ...D for PWR1 PWR2 and Fault LAN Port 5 8 10 100 1000Tx Hard Physical Reset Button Console Port USB Backup LAN Port 1 4 10 100 1000Tx LED for 1000Tx network speed Status LED for 10 100Tx network speed Status Figure 2 2 The Front Panel of LMX 0800G Series 2 3 Top View Figure 2 3 below shows the top panel of the LMX 0800G series switch that is equipped with one 6 pin removal terminal block connector fo...

Page 10: ... and no active port alarm is detecting errors Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Network is active Off Ring Network is not active LAN Port 1 8 Left LED Green On Connected to network 1000Mbps Flashing Networking is active Off Not connected to network LAN Port 1 8 Right LED Green On Networking is active 100 10Mbps Flashing Network...

Page 11: ...x 3 Tx 6 Tx Table 2 3 RJ45 Pin Assignments Note The and signs represent the polarity of the wires that make up each wire pair All ports on this industrial Ethernet switch support automatic MDI MDI X operations Users can use straight through cables see figure below for all network connections to PCs servers and other switches or hubs With straight through cabling pins 1 2 3 and 6 are at one end of ...

Page 12: ... Wiring the Power Inputs Caution Please follow the steps below when inserting the power wire 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 6 Figure 2 6 Power Terminal Block 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 7 Figure 2 7 Power Terminal Block ...

Page 13: ...arm contact is shown below in Figure 2 13 Figure 2 13 Wiring the Fault Alarm Contact Caution The wire gauge for the terminal block should range between 12 24AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm 2 10 Grounding Note Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground co...

Page 14: ...e of the industrial Ethernetswitch Caution The torque for tightening the screws on the device is 3 5 in lbs 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 5 Chec...

Page 15: ...all mounting brackets on the top and bottom of the industrial Ethernetswitch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrialEthernet switch on the wall 5 To remove the wall mount bracket do the opposit...

Page 16: ...the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the PowerInputs section Please refer to the LED Indicators section for LED light indication 5 Prepare the twisted pair straight through category 5 cable for Ethernet connection 6 Insert one side of the RJ 45 cable into switch s Ethernet port and on the other sid...

Page 17: ...he different faces of the device This may not only harm the internal layout but might cause harm to user as well Do not under any circumstance open the device for any reason Please contact your dealer for any repair needed or follow the instructions within the manual Clean the device with dry soft cloth ...

Page 18: ... Stacked VLAN Q in Q IEEE 802 1p QoS CoS Protocol for Traffic Prioritization Switch Protocol IGMPv1 v2 SNMPv1 v2c v3 TFTP SNTP SMTP RMON HTTP HTTPS Telnet Syslog DHCP Option 66 67 82 SSH SSL Modbus TCP LLDP IPv4 IPv6 Data Process Store and Forward Transfer Rate 14 880 pps for 10Base Tx Ethernet port 148 800 pps for 100Base TX Fast Ethernet port 1 488 000pps for 1000Base TxGigabit Ethernet port Pac...

Page 19: ... Watts Environmental Limits Operating Temperature STD 10 to 70 C 14 to 158 F EOT 40 to 75 C 40 to 167 F Storage Temperature 40 C 85 C 40 F 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Class A EMS IEC6100 4 2 3 4 5 6 8 IEC6100 6 2 IEC6100 6 4 Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration Safety UL 61010 1 UL 61010 2 201 T...

Reviews: