ANTAIRA LMP-C602G-SFP-bt-T-V2 Hardware Manual Download Page 3

Antaira Technologies - Industrial Ethernet Switches 
LMP-C602G-SFP-bt-V2 Series - Hardware Manual - v1.0 

 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected. 

Consult the dealer or an experienced radio/TV technician for help. 

 

Caution:​ Any changes or modifications not expressly approved by the grantee of this device could void 

the user’s authority to operate the equipment. 

 

Avertissement FCC 

Cet équipement a été testé et déclaré conforme aux limites d'un appareil numérique de classe A, 

conformément à la partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection 

raisonnable contre les interférences nuisibles dans une installation résidentielle. Cet équipement génère, 

utilise et peut émettre de l'énergie radiofréquence. Cela peut provoquer des interférences nuisibles aux 

communications radio si l'équipement n'est pas installé et utilisé conformément aux instructions. 

Cependant, il n'y a aucune garantie qu'aucune interférence ne se produira dans une installation 

particulière. Si cet équipement provoque des interférences nuisibles à la réception radio ou télévision, ce 

qui peut être déterminé en éteignant puis en rallumant l'équipement, l'utilisateur est encouragé à essayer 

de corriger les interférences par une ou plusieurs des mesures suivantes: 

Réorientez ou déplacez l'antenne de réception. 

Augmentez la distance entre l'équipement et le récepteur. 

Connectez l'équipement à une prise sur un circuit différent de celui auquel le récepteur est 

connecté. 

Consultez le revendeur ou un technicien radio / TV expérimenté pour obtenir de l'aide. 

 

CE Mark Warning 

This is a Class-A product. In a domestic environment, this product may cause radio interference in which 

case the user may be required to take adequate measures. 

 

Avertissement de marque CE

 

Ceci est un produit de classe A. Dans un environnement domestique, ce produit peut provoquer des 

interférences radio, auquel cas l'utilisateur peut être amené à prendre des mesures adéquates. 

Summary of Contents for LMP-C602G-SFP-bt-T-V2

Page 1: ...02G SFP bt V2 Series 6 Port Industrial Compact Gigabit IEEE 802 3bt PoE Light Layer 3 Managed Ethernet Switch with 4 10 100 1000Tx 90W Port and 2 100 1000 SFP Slots Hardware Manual Version 1 0 Februar...

Page 2: ...y and fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice A...

Page 3: ...communications radio si l quipement n est pas install et utilis conform ment aux instructions Cependant il n y a aucune garantie qu aucune interf rence ne se produira dans une installation particuli r...

Page 4: ...trial Grade Managed Ethernet Switches Hardware Manual Version 1 0 February 2021 The manual supports the following models LMP C602G SFP bt V2 LMP C602G SFP bt T V2 This document is the current official...

Page 5: ...4 2 2 Front View Panel 5 2 3 LED Indicators 5 2 4 PoE Port LED Indicators 7 2 5 DIP Switch 10 2 6 Relay Contact Alarm Warning 10 2 7 Reset Button 11 2 8 Ethernet Ports 11 2 9 Cabling 12 2 10 Wiring th...

Page 6: ...65 C or an extended temperature range EOT 40 C to 75 C 1 1 Product Hardware Features System Interface and Performance All RJ45 ports support Auto MDI MDI X Function Embedded 4 10 100 1000Tx 90W Port R...

Page 7: ...P snooping v1 v2 v3 IGMP filtering throttling IGMP query up to 1024 group Supports IPv4 IPv6 RMON MIB II port mirroring event syslog DNS NTP SNTP HTTPS SSH SSL TFTP MODBUS TCP for SCADA system integra...

Page 8: ...entr e d alimentation Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du commutateur Ethernet industriel seront d crits dans ce manuel d utilisation W...

Page 9: ...witches LMP C602G SFP bt V2 Series Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 64 9mm x 89 8m...

Page 10: ...dicators There are LED light indicators located on the front panel of the industrial Ethernet switch that display the power status and network status Each LED indicator has a different color and has i...

Page 11: ...RPS Owner Mode is not active Ring R Green On ERPS Ring Network is active Flashing ERPS Ring Network works abnormally or misconfigured Off ERPS Ring Network is not active PoE Load Off No PD connect Gre...

Page 12: ...e PoE port of the lowest priority PoE port will be shut down The PoE LED of the port will act cyclically as below until the port is recovered from the event 7 Amber On Connected to network 10 100Mbps...

Page 13: ...t Amber IEEE 802 3bt Green PoE Port Over Current Event PoE Port Overload Event When the current limit of the specific PoE port is exceeded the PoE power will be shut down The PoE LED of the port will...

Page 14: ...PoE port is recovered from the Cable Short event the PoE LED of the port will act cyclically as below until the event indicator is clear manually Figure 2 8 PoE Cable Short Recovering LED Sequence IE...

Page 15: ...he front panel of the Ethernet switch works as the PoE controller for PoE port 1 4 Table 2 2 DIP Switch Functions 2 6 Relay Contact Alarm Warning 2 pin 1 24VDC 1A resistive normal open on 6 pin termin...

Page 16: ...to Table 2 3 for the timing and function Table 2 3 Reset Button Functions 2 8 Ethernet Ports RJ45 Ports RJ45 Ports Auto MDI MDI X The RJ45 ports are auto sensing for 10Base T 100Base TX or 1000Base T...

Page 17: ...ransceiver used in optical communications for both telecommunication and data communication applications Caution Please employ optional optical transceiver SFP Fixed Fiber that complies with IEC 60825...

Page 18: ...e PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 11 Figure 2 11 Power Terminal Block 2 Tighten the wire clamp screws to prevent the wires from loosening...

Page 19: ...managed industrial switch only and form a normal open circuit An example is shown below in Figure 2 13 Figure 2 13 Wiring the Fault Alarm Contact Caution The wire gauge for the terminal block should...

Page 20: ...magnetic Interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown below in Figure 2 14 Figure 2 14 Grou...

Page 21: ...he rear side of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2...

Page 22: ...ande industriel 1 Remove the DIN Rail bracket from the industrial Ethernet switch by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 U...

Page 23: ...Ethernet Switches LMP C602G SFP bt V2 Series Hardware Manual v1 0 Figure 3 4 Remove DIN Rail bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall...

Page 24: ...f it is required to wall mount the industrial Ethernet switch please refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall pl...

Page 25: ...ter is being used Never use a power supply or adapter with a non compliant DC output voltage or it will burn the equipment Select the proper UTP or STP cable in order to construct the network Use an u...

Page 26: ...ing ActiPHY PerfectReach IEEE 802 3az EEE power management Network Redundancy STP RSTP MSTP port trunk with LACP ERPS v1 v2 50ms Configuration Http Https Telnet SSH CLI TFTP SNMP v3 System Diagnostics...

Page 27: ...Link Active PoE Load 50 70 90 Protection Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseT...

Page 28: ...rial will be announced on the Antaira website 23 PoE Pin Assignment V V V V for pin 1 2 3 6 V V V V for pin 4 5 7 8 Support Modes Mode A Mode B 4 Pair Mode PoE Power Budget 240W 48 55VDC System Power...