Antaira Technologies - Industrial Ethernet Switches
LMP-0601G-SFP-V2 Series Hardware Manual V1.0
8
Pin MDI-X
Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)
Table 2.4 - Ethernet Signal Pin
The following figures show the cabling schematics for straight-through and crossover.
Figure 2.4
Straight-Through Cable Schematic
Figure 2.5
Crossover Cable Schematic
2.7 Cabling
Use the four twisted-pair, category 5e, or the above cabling for the RJ-45 port connections. The
cable between the switch and the link partner (switch, hub, workstation, etc.) must be less than
100 meters (328 ft.) in length.
2.8 Wiring the Power Inputs
Please follow the steps below when inserting the power wire.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in
Figure 2.6
.
Figure 2.6 - Power Terminal Block
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.7
.
Figure 2.7 - Power Terminal Block