Antaira Technologies - Industrial Media Converter 

IMC-100A Series User Manual V1.0 

 

14 

 

6. Trouble Shooting 

 

 

Always  verify the right power cord  or adapter is being used. Never use a  power  supply  or 

adapter with a non-compliant DC output voltage or it will burn the equipment. 

 

 

Select the  proper  UTP or  STP cable  in  order to construct the network.  Use an  unshielded 

twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 conne

ctions: 100Ω Category 

5e for 10/100/1000Mbps.  Also  be sure that  the length of any twisted-pair connection does 

not exceed 100 meters (328 feet). 

 

 

Diagnosing LED Indicators:

 To assist in identifying problems, the media converter can be 

easily monitored with the LED indicators which help to identity if any problems exist.   

o

 

Please refer to the LED Indicators section for LED light indication. 

 

 

If  the  power  indicator  LED  does  not  turn  on  when  the  power  cord  is  plugged  in,  the  user 

may have a problem with the power cord. Check for loose power connections, power losses 

or surges at the power outlet.   

o

 

Please contact Antaira for technical support service, if the problem still cannot 

be resolved.   

 

 

If  the  industrial  media  converter  LED  indicators  are  normal  and  the  connected  cables  are 

correct  but  the  packets  still  cannot  transmit,  please 

check  the  system’s  Ethernet  devices’ 

configuration or status. 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for IMC-100A Series

Page 1: ...Antaira Technologies Industrial Media Converter LNP 0500G Series User Manual V1 0 i IMC 100A Series 10 100Tx to 100Fx Industrial Media Converter Version 1 0 User Manual...

Page 2: ...tice Copyrights 2015 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under t...

Page 3: ...g measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the rece...

Page 4: ...scription 3 2 1 Physical Dimensions 3 2 2 Front Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Ethernet Ports 5 2 6 Cabling 6 2 7 Wiring the Power Inputs 7 2 8 Wiring the Fault Alarm Contact 7 3 Moun...

Page 5: ...D 10 C to 70 C or an extended temperature range EOT 40 C to 75 C It also provides Ethernet and fiber optic connectivity for outdoor or harsh industrial environment applications such as security survei...

Page 6: ...Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet media converter s hardware specs ports...

Page 7: ...nual V1 0 3 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies IMC 100A series 10 100Tx to 100Fx industrial media converter W x D x H...

Page 8: ...C 100A series media converter that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 48VDC Figure 2 2 Front Panel of the IMC 100A Series Figure 2 3 Top Panel View...

Page 9: ...ower inputs Fiber Port Yellow Green FDX COL Solid Full Duplex Mode Flashing Packet Collision Green Link ACT Networking is active Off Not connected to network RJ45 Ethernet Port Green 100M Linked to ne...

Page 10: ...ght through and crossover cables 2 6 Cabling Twisted pair segments can be connected with an unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 10...

Page 11: ...rews to prevent the wires from loosening as shown below in Figure 2 7 Note Only use copper conductors 60 75 C tighten to 5 lbs The wire gauge for the terminal block should range between 18 20 AWG 2 8...

Page 12: ...00A Series User Manual V1 0 8 Note The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate the power f...

Page 13: ...Mounting The DIN Rail is pre installed on the industrial Ethernet media converter from the factory If the DIN Rail is not on the industrial Ethernet media converter please refer to Figure 3 1 to learn...

Page 14: ...osite from step 1 3 After the DIN Rail bracket is installed on the rear side of the media converter insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the...

Page 15: ...e wall mounting brackets on the top and bottom of the industrial media converter 3 Use the screws to screw the wall mounting bracket on the industrial media converter 4 Use the hook holes at the corne...

Page 16: ...tion 3 To hang the industrial Ethernet media converter on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet media converter and then the power LED...

Page 17: ...dustrial Media Converter IMC 100A Series User Manual V1 0 13 5 Network Application This segment provides an example of an industrial Ethernet media converter application Figure 5 1 Figure 5 1 Networki...

Page 18: ...28 feet Diagnosing LED Indicators To assist in identifying problems the media converter can be easily monitored with the LED indicators which help to identity if any problems exist o Please refer to t...

Page 19: ...r1 Green Power2 Green Fault Red Per port Link Activity Green Network Cable 10BaseT 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100BaseTX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m...

Page 20: ...ntaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support antaira com www antaira eu in...

Reviews: