background image

ARS-7235-5E-AC Series

Industrial 5-Port Gigabit Ethernet with Dual Radio IEEE 802.11a/b/g/n/ac

Wireless Access Point/Client/Bridge/Repeater/Router

Hardware Manual

Version 1.0

(December 2021)

Summary of Contents for ARS-7235-5E-AC Series

Page 1: ...ARS 7235 5E AC Series Industrial 5 Port Gigabit Ethernet with Dual Radio IEEE 802 11a b g n ac Wireless Access Point Client Bridge Repeater Router Hardware Manual Version 1 0 December 2021 ...

Page 2: ...ty and fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodically made to the information contained herein and will be inc...

Page 3: ...ications radio si l équipement n est pas installé et utilisé conformément aux instructions Cependant il n y a aucune garantie qu aucune interférence ne se produira dans une installation particulière Si cet équipement provoque des interférences nuisibles à la réception radio ou télévision ce qui peut être déterminé en éteignant puis en rallumant l équipement l utilisateur est encouragé à essayer de...

Page 4: ...ints Industrial Grade Wireless Access Points Hardware Manual Version 1 0 December 2021 The manual supports the following models ARS 7235 5E AC ARS 7235 5E AC T This document is the current official release hardware manual Please check our website www antaira com for any updated manual or contact us by e mail support antaira com ...

Page 5: ...nsions 3 2 2 Front View Panel 4 2 3 Top View Panel 5 2 4 LED Indicators 5 2 5 Reset Button 6 2 6 Ethernet Ports 6 2 7 Cabling 7 2 8 Wireless Antenna 8 2 9 Wiring the Power Inputs 8 2 10 Wiring the Fault Alarm Contact 9 2 11 Grounding Note 10 3 Mounting Installation 11 3 1 DIN Rail Mounting 11 3 2 Wall Mounting 12 4 Hardware Installation 14 4 1 Installation Steps 14 4 2 Maintenance and Service 15 4...

Page 6: ...istance deployments The unit also allows the user to position the wireless antennas in a better signal broadcasting location for improved wireless coverage and signal strength or simply in a more convenient location 1 1 Product Hardware Features System Interface and Performance All RJ45 ports support the auto MDI MDI X function Embedded 5 10 100 1000Tx RJ45 ports Qualcomm IPQ4029 SoC WLAN supports...

Page 7: ...positif de protection sur l entrée d alimentation Les spécifications matérielles les ports les informations de câblage et l installation du câblage du point d accès sans fil industriel seront décrits dans ce manuel du matériel Warning Labels The caution label means that you should check certain information on the user manual when working with the device Shown in Figure 1 1 Étiquettes d avertisseme...

Page 8: ...s Access Points ARS 7235 5E AC Series Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 54mm x 99mm x 142mm Figure 2 1 Physical Dimensions 3 ...

Page 9: ...ira Technologies Industrial Wireless Access Points ARS 7235 5E AC Series Hardware Manual v1 0 2 2 Front View Panel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View Panel 4 ...

Page 10: ...cess point that display the power status and network status Each LED indicator has a different color and has its own specific meaning see below in Table 2 1 LED Color Description P1 Green On Power input 1 is active Off Power input 1 is inactive P2 Green On Power input 2 is active Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Preconfigured alarms are detecting failur...

Page 11: ...rs Note P1 is the abbreviation for Power 1 P2 is for Power 2 LNK is for Link and ACT is for Activity 2 5 Reset Button There is a reset button located on the front panel of the industrial wireless access point that helps users to reboot restore default or save running configurations by pressing the button for different seconds Please refer to Table 2 2 for the timing and function Seconds Function 4...

Page 12: ...ossover Cable Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 TP0 3 TP1 1 TP0 1 TP1 2 TP0 6 TP1 2 TP0 2 TP1 3 TP1 1 TP0 3 TP1 3 TP0 4 TP2 7 TP3 4 TP2 4 TP3 5 TP2 8 TP3 5 TP2 5 TP3 6 TP1 2 TP0 6 TP1 6 TP0 7 TP3 4 TP2 7 TP3 7 TP2 8 TP3 5 TP2 8 TP3 8 TP2 Table 2 3 1000Base T RJ45 Pin Assignments Note and signs represent the polarity of the wires that m...

Page 13: ...limentation 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 6 Figure 2 6 Power Terminal Block 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 7 Figure 2 7 Power Terminal Block Caution Only use copper conductors 125 C tighten to 5 lbs The wire gauge for the ...

Page 14: ...managed industrial switch only and form a normal open circuit An example is shown below in Figure 2 8 Figure 2 8 Wiring the Fault Alarm Contact Caution The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Attention Le calibre des fils du bornier doit être compris entre 12 et 24 AW...

Page 15: ...omagnetic Interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown below in Figure 2 9 Figure 2 9 Grounding Screw Symbol Caution Using a shielded cable achieves better electromagnetic compatibility Attention L utilisation d un câble blindé permet une meilleure compatibilité électromagnétique 10 ...

Page 16: ...ll the DIN Rail bracket on the rear side of the industrial wireless access point Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the wireless access point insert the top of ...

Page 17: ... wall Attention Wall signifie mur de panneau de commande industriel 1 Remove the DIN Rail bracket from the industrial wireless access point by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial wireless access point 3 Use the screws to screw the wall mounting bracket on the industrial wireless access point Caution The torque for tightening the screws on...

Page 18: ...hnologies Industrial Wireless Access Points ARS 7235 5E AC Series Hardware Manual v1 0 5 To remove the wall mount bracket do the opposite from the steps above Figure 3 4 Remove DIN Rail bracket from the Switch 13 ...

Page 19: ...t If the DIN Rail is not screwed on the industrial wireless access point please refer to the DIN Rail Mounting section for DIN Rail installation If it is required to wall mount the industrial wireless access point please refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial wireless access point on a DIN Rail or wall please refer to the Mounting Installation se...

Page 20: ...ipation holes located in the different faces of the device This may not only harm the internal layout but might cause harm to users as well Do not under any circumstance open the device for any reason Please contact your dealer for any repair needed or follow the instructions within the manual Clean the device with dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter is...

Page 21: ...a problem with the power cord Check for loose power connections power losses or surges at the power outlet Please contact Antaira for technical support service if the problem still cannot be resolved If the industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit please check the system s Ethernet devices configuration or status 16 ...

Page 22: ...Client Bridge Repeater Router Encryption Security WPA WPA2 WPA3 WEP TKIP AES RADIUS 802 1x EAP Interface Ethernet Ports 5 10 100 1000Tx WLANs Dual Band 2 4GHz 5GHz concurrent Antennas 2 External SMA Antennas 3dBi for 2 4GHz 5dBi for 5GHz MIMO support Dual 2Tx Rx LED Indicators Power Fault Wi Fi Signal Diagnostic Activity Frequency Range IEEE 802 11a b g n ac 2 4GHz 2 402G 2 482GHz 25dBm IEEE 802 1...

Page 23: ...latory Approvals EMI FCC Part 15 Subpart B CE EN55032 EMS CE EN55024 IEC61000 4 2 3 4 5 6 8 11 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Green RoHS Compliant Certifications FCC CE Warranty 5 Years Table 5 1 Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9...

Reviews: