background image

 

 

Industrial Wireless Access Point 
Hardware User's Manual 

– AMS-2111   

1. Overview 

 

 

Antaira Technologies’ AMS-2111 series

 is designed for industrial and enterprise wireless access 

applications. Embedded with the Qualcomm/Atheros AR9331 SoC chipset, it boasts network robustness, 
stability, and wider network coverage. Based on IEEE 802.11 b/g/n, the access point supports high-speed 
data transmission of up to 150MBps.   
 
The AMS-2111 series is capable of operating in different modes, which makes it suitable for a wide variety of 
wireless applications including long-distance deployments. The unit also allows the user to position the 
wireless antenna in a better signal-broadcasting location for improved wireless coverage and signal strength 
or simply in a more convenient location. 
 

 

1.1 Key Features 

 

System Interface/Performance 

 

Qualcomm/Atheros AR9331 SoC 

 

2* 10/100BaseT(X) RJ45 Ethernet Ports 

 

WLAN supports 2.4GHz Wi-Fi 

 

One Industrial External SMA Antenna 3dBi for 2.4GHz 

 

Power Input 

 

DC 9~48V a 4-pin removal terminal block 

 

Operating Temperature 

 

Standard operating temperature model: 0°C ~ 60°C 

 

Extended operating temperature model (

–T): -40°C ~ 75°C 

 

Case/Installation 

 

IP-30 protection 

 

DIN-Rail and wall mount design 

 

 

1.2 Package Contents 

 

1 - Quick Installation Guide 

 

– AMS-2111 Series 

 

1 - Wall Mounting Bracket Set with Screws 

 

– Terminal Block 

 

 

 

 

Summary of Contents for AMS-2111 Series

Page 1: ...1 Industrial Wireless Access Point Hardware User s Manual AMS 2111 AMS 2111 Series Industrial IEEE 802 11 b g n 2 4GHz Wireless AP Client Bridge Repeater Version 1 0 October 2018 User Manual...

Page 2: ...stered trademarks of their respective owners Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warrant...

Page 3: ...g the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between...

Page 4: ...ion 2 2 Hardware Description 3 2 1 Physical Dimensions 3 2 2 Front Panel 4 2 3 LED Indicators 5 2 4 Ethernet Ports 6 2 5 Wireless Antenna 6 2 6 Cabling 7 2 7 Wiring the Power Inputs 7 2 8 Grounding No...

Page 5: ...ce deployments The unit also allows the user to position the wireless antenna in a better signal broadcasting location for improved wireless coverage and signal strength or simply in a more convenient...

Page 6: ...n the power supply input Supply by UL Listed industrial use power The industrial wireless AP s access point hardware specs ports cabling information and wiring installation will be described within th...

Page 7: ...Access Point Hardware User s Manual AMS 2111 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of AMS 2111 series W x H x D is 26mm x 95mm x 75mm Figure 2...

Page 8: ...2 Front Panel The front panel of the AMS 2111 series can be seen below Figure 2 2 Figure 2 2 Front Panel LED for Power Grounding Screw behind ETH1 Port 4 Pin Removal Terminal Block Power Input Reset...

Page 9: ...Table 2 3 LED Color Description Power Green On Power input is active Off Power input is inactive WLAN Signal Strength Green Red Red Less than 25 signal strength Green LED 2 Less than 50 signal strengt...

Page 10: ...onnect to another switch or workstation without changing the straight through or crossover cabling See the figures shown below for the straight through and crossover cabling schematics Figure 2 3 RJ 4...

Page 11: ...eless AP switch hub workstation etc must be less than 100 meters 328 ft long 2 7 Wiring the Power Inputs Please follow the steps below to insert the power wire 1 Insert the positive and negative wires...

Page 12: ...ng devices The grounding screw symbol is shown blow in Figure 2 9 Figure 2 9 Grounding screw Caution Using a shielded cable achieves better electromagnetic compatibility 3 Mounting Installation 3 1 DI...

Page 13: ...Caution The torque for tightening the screws on the device is 3 5 in lbs 2 To remove the DIN Rail bracket do the opposite from Step 1 3 After the DIN Rail bracket is installed on the rear side of the...

Page 14: ...strial control panel wall 1 Remove the DIN Rail bracket from the industrial wireless AP by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial wireless AP 3...

Page 15: ...11 Industrial Wireless Access Point Hardware User s Manual AMS 2111 Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions...

Page 16: ...er LED light will turn on a For wiring power please refer to the Wiring the Power Inputs section b Please refer to the LED Indicators section for LED light indication 5 Prepare the twisted pair straig...

Page 17: ...pen the device for any reason Please contact your dealer for any repair needed or follow the instructions within the manual Clean the device with dry soft cloth Antaira Customer Service and Support An...