Balance Charger xMove 2.0/xBase 2.0
15
18. Charging Pb Battery
19. Discharging Pb Battery
Set up the charge current on the left and the nominal voltage of the
battery on the right. The charge current ranges from 0.1 to 5.0 A and
the voltage should be matched with the battery being charged.
Start the charge process bu pressing “Start/Enter” key for more than
3 seconds.
The screen displays the state of charging process. To stop charging
forcibly, press “Batt type/Stop” key once
The audible sound indicates you at the end of process.
Set discharge current on the left and final voltage on the right. The
discharge current ranges form0.1 to 1.0 A.
To start the process, press “Batt type/Stop” key for more than
3 seconds.
The screen displays the current state of discharge. You can alter the
discharge current by pressing “Start/Enter” key during the process.
Once you change the current value, store it by pressing “Start/Enter”
button again.
To stop discharging press “Batt type/Stop” key once. The audible
sound indicates you at the end of process.