9-b. MOUNTING THE MOTOR RISERS OR FOOT
1.
If your pump is Group 2 ANSI
(K+326, K+436 or K+3158) mount
the foot to the bracket. Bolt the
appropriate foot to the bottom of the
bracket with 3 stainless steel bolts
(1/2-13 UNC.) Torque to 40 ft-lb.
Motor frames 213/215TC and larger
require motor risers.
2.
Group 1 ANSI pumps (K+1516,
K+3156, K+326S or K+1518) do not
use the bracket foot or motor risers
except on 284/286TSC frames.
P2536
Fig. 9-4 Group 2 Pump
Fig.9-5 Motor Foot
9-c. MOUNTING DRIVE END TO WET END
1.
Thread the two jack screws through
the front flange of the bracket until
they protrude as far forward as
possible.
2.
Line up the wet end with front of the
bracket.
3. While firmly grasping the inlet and
outlet flanges or the outside of the
casing, carefully guide the wet end
into the bracket. Retract the jack
screws a few turns at a time. The
strong magnetic attraction will grab
the wet end when you get close
enough, pulling it into the bracket
forcefully.
RECOMMENDED
NOT RECOMMENDED
DANGEROUS
Fig. 9-6
CAUTION!: Be very careful to keep fingers away from mating faces to avoid injury!
9-d. Aligning Pump Mounting Feet
Set the complete pump assembly on its feet on a flat surface. Ensure that all feet are flat on the surface.
This may require slightly loosening the bolts at the three piloted joints – the rear support to pump case,
the bracket to rear support and the bracket to motor mounting plate. Adjust the clocking of the parts at
these joints as required to get all feet to sit flat. This may require lightly tapping on any foot not in
contact with the flat surface, or tapping on the parts adjacent to the joints. Re-snug all bolts. Then
torque all bolts in increasing torque values in a star pattern at each joint. Final torque at all three joints
is 40 ft-lb (54N-m.)