36
Options \ Content
Setting Content
Trigger
Off
On
On
Option
-
Infinite Printing
Finite Printing
Count
-
-
0-65535
Initial Delay
-
0-5548mm
0-5548mm
Gap
10-5548mm
10-5548mm
10-5548mm
Use
Auto repeat printing
Photocell
trigger,
infinite number of prints
Photocell trigger, finite
number of prints
Real Time Refresh
Print time related information, the frequency of the update time. Can set instant
refresh (follow system time) or set time interval update (setting range: 1~9 minutes).
Clean Nozzles
Used when ink is stuck or clogged at the nozzles.
4.5.3
Device Settings
Devices settings include the settings of photocell, encoder, WIFI and Ethernet settings
items are as follow:
Photocell Source: it can be external or internal, system default is internal. After
photocell is installed, user must manually set external option.
Photocell Mode: trigger photocell mode can be positive or negative edge trigger.
Encoder: after encoder is installed, user must manually set external option and user
should choose printhead resolution same as the encoder when using external encoder.
Conveyor Speed: input current conveyor speed, this function is only available when
encoder is off.
Box Width: set target width (Unit: mm)
Wireless Network: set the settings related to WIFI connection. This feature is only
enabled when USB to WIFI dongle is connected.
Ethernet: set the settings related to Ethernet connection. This feature is only enabled
when USB to Ethernet dongle is connected.