Anritsu Network Data Analyzer MD6430A Specifications Download Page 4

IP/NETWORK MEASURING INSTRUMENTS

http://www.anritsu.com

220

Model/Order No.

Name

Main frame

MD6430A 

Network Data Analyzer

Standard accessories

Z0695

AC adapter:

1 pc

Power cord:

1 pc

Z0406A 

Touch pen (for touch panel): 

1 pc

Z0402A 

Protective cover (protects display):

1 pc 

W1542AE 

MD6430A operation manual (includes 
MU643000A/B/C):

1 copy

W1543AE 

MD6430A remote control operation manual
(includes MU643000A/B/C):

1 copy

Z0417 

MD6430A sample program (remote sample program): 1 pc 

Z0403A 

Belt with hook (MD6430A carrying belt): 

1 pc

Option

MD6430A-01

GPIB

Units

MU643000A 

Datacom Interface Unit (for Europe and Japan)

MU643000B 

Datacom Interface Unit (for Japan)

MU643000C 

Datacom Interface Unit (for Europe)

Options

MU643000A-01 

JT-Q921/Q931 ISDN signaling

MU643000A-02 

ETSI ISDN signaling

MU643000B-01 

JT-Q921/Q931 ISDN signaling

MU643000C-02 

ETSI ISDN signaling

MU643000A-22

CAS/FAS option (for Europe and Japan)

MU643000B-22

CAS/FAS option (for Japan)

MU643000C-22

CAS/FAS option (for Europe)

Optional accessories

Z0619 

Lithium ion battery pack (battery pack for main frame)

B0441 Hard 

carrying 

case

B0442 Soft 

carrying 

case

B0443 

Rack mount kit

A0006 Headset
J1026A

GPIB cable (for MD6430A-01’s accessory), 2 m

J0654A 

Serial interface cross cable [D-Sub 9-pin (female) · D-Sub 
9-pin (male)], 2 m (for remote control of main frame)

J0661A 

RS-232C straight cable [D-Sub 9-pin (female) · D-Sub 
25-pin (male)], 2 m (for remote control of main frame)

J0920B 

Cross cable [D-Sub 9-pin (female) · D-Sub 25-pin (male)], 
3 m (for remote control of main frame)

J0913A 

Measurement cable [D-Sub 25-pin (male) · half pitch 
36-pin], 2 m (for V.24/V.28)

J0914A 

Measurement cable [V.35 connector (male) · half pitch 
36-pin), 2 m (for V.35)

Model/Order No.

Name

J0915A 

Measurement cable [D-Sub 37-pin (male) · half pitch 
36-pin], 2 m (for V.36/RS-449)

J0916A 

Measurement cable [D-Sub 15-pin (male) · half pitch 36-pin], 
2 m (for X.20/X.21, using B terminal as ST1 output type)

J0945 

Measurement cable [D-Sub 15-pin (male) · half pitch 36-pin], 
2 m (for X.20/X.21, using B terminal as ST2 input type)

J0929 

Cross measurement cable [D-Sub 15-pin (male) · half 
pitch 36-pin], 2 m (for X.20/X.21 MUX/DEMUX)

J0388B 

DCE/DTE conversion adapter (D-Sub 25-pin, for V.24/V.28)

J0390 

DCE/DTE conversion adapter (D-Sub 34-pin, for V.35)

J0392B 

DCE/DTE conversion adapter (D-Sub 37-pin, for 
V.36/RS-449)

J0917A 

TTL/CMOS connection box

1

(I/O connector: BNC type)

J0923 

Measurement cable (both-end Amphenol half pitch 36-pin), 
1 m (for connection between MD6430A to TTL/CMOS)

J0463C 

Measurement cable [both-end 8-pin modular (RJ45) with 
shield], 2 m (for 192k)

J0959B

Measurement cable (RJ45 8-pin modular · clip), 2 m (for 192K)

J0844A 

ISO1073 cable [both-end 8-pin modular (ISO10173)], 2 m 
(for 1.5M, 2M)

J0127B 

Coaxial cord (BNC-P · RG58A/U · BNC-P), 2 m (for 2M, 6M)

J0939

Coaxial cord (C-H3T type plug · BNC), 2 m (for 6M)

J0921B 

Measurement cable [8-pin modular (ISO10173) · M-1PS], 
2 m (for 1.5M, 2M)

J0922B Measurement 

cable 

(mini-BANTAM 

· M-1PS), 2 m 

(for 64k, 2M CMI)

J0924B Measurement 

cable 

(mini-BANTAM 

· I-214APS), 2 m (for 

external input clock, 64k + 8k)

J0930 Measurement 

cable 

(mini-BANTAM 

· M-3912), 2 m (for 

64k, Siemens type)

J0960B

Measurement cable (mini-BANTAM · clip), 2 m (for 64k, 2M, CMI)

J0946A 

Measurement cable [8-pin modular (ISO10173) · M-3912], 
1 m (for 1.5M/2M)

J0946B 

Measurement cable [8-pin modular (ISO10173) · M-3912], 
2 m (for 1.5M/2M)

J0950 

Measurement cable [8-pin modular (ISO10173) · clip], 
2 m (for 1.5M/2M)

J0968

Balance cable (RJ45 · ISO10173), 2 m (for 192k)

J0969C

Unbalance cable [SP3CP/3CV-P (BNC)], 2 m (for 6M)

J0925B 

Y cable (D-sub 25-pin · half pitch 36-pin/D-sub 25-pin), 
2 m (for V.24/V.28 monitor)

J0926B 

Y cable (D-sub 25-pin · half pitch 36-pin/D-sub 25-pin), 
2 m (for V.35 monitor)

J0927B Y 

cable 

(V.37 

· half pitch 36-pin/D-sub 37), 2 m (for 

V.36/RS-449 monitor)

J0928B 

Y cable (D-sub 15-pin · half pitch 36-pin/D-sub 15-pin), 
2 m (for X.20/X.21 monitor)

ISDN calling/called function

INS64, INS1500 (Option: MU643000A/B-01), ETS1 ISDN (Option: MU643000A/C-02)

MUX/DEMUX 

Able to drop/insert specified channels in high-speed interface through X.21 interface at 64k x n (n = 1 to 98)

Voice communication 

Voice communication possible in any TS in high-speed interfaces (except G.703 64 kbit/s)

Error analysis 

Displays sequential error/alarm measurement data and graphs

Signal monitor lamp 

Indicates status of each signal line

External printer 

Interface Centronics, D-sub 25-pin connector

Enables printout of error measurement data

Measurement start time: Prints time and measurement conditions

External printer output 

During measurement: Prints specified error and alarm occurrence at each detected instance or at predefined time interval
Measurement stop time: Prints measured total results
Prints on screen contents

Display 

Color TFT-LCD (8.4 inch)

Remote interface 

RS-232C, D-sub 9-pin connector, GPIB (option)

Memory 

3.5 inch FDD

Built-in timer 

Year, month, day, hour, minute, second

Power supply 

AC: 85 to 250 V, DC: Lithium ion battery (rechargeable, optional accessory), 50 VA

Battery operation time 

3 h (max.)  

5 h when using power save function

Operating temperature 

0 to +50˚C, (FDD and at battery usage: +5 to +40˚C)

Dimensions and mass 

290 (W) x 194 (H) x 94 (D) mm, 

4.2 

kg

(excluding battery)

EMC

EN61326: 1997/A2: 2001 (Class A), EN61000-3-2: 2000 (Class A), EN61326: 1997/A2: 2001 (Annex A)

LVD

EN61010-1: 2001 (Pollution Degree 2)

1: Specification when using MU643000A Datacom Interface

2: Specification when using MU643000B Datacom Interface

Ordering information

Please specify model/order number, name, and quantity when ordering.

1: Cable (J0923) required when using with TTL/CMOS interface

Note: For details of the measurement cable, refer to the Measurement Cable Selection Guide in the  MD6430A Application Note.

3: Specification when using MU643000C Datacom Interface

4: Max. n value depends on interfaces

Summary of Contents for Network Data Analyzer MD6430A

Page 1: ...nits designed to meet customer needs Wide variety of measurement functions Various measurements such as error alarm clock slip delay fre quency and digital level can be performed Also can send user pat terns with tracing functions Frame relay measurements Frame relay network connections conforming to PVC and ITU T Q 933 Annex A can be tested by the MD6430A The user can also monitor the congestion ...

Page 2: ...ondition can be logged and displayed as his tograms The received data can also be captured Supports ISDN networks BRI PRI The unit can be connected to the ISDN public telephone network Return testing using one unit can be done by using the call loop func tion as below Voice channel function The CODEC function permits voice communications over a specified channel Simultaneous voice communications a...

Page 3: ...erted Receive clock Internal clock Async low speed interface 50 75 100 110 150 200 256 300 400 500 512 600 768 800 1k 1 2k 1 6k 1 8k 2k 2 4k 2 56k 3k 3 2k 3 6k 4 8k 7 2k 8k 9 6k 12k 12 8k 14 4k 16k 16 8k 19 2k 28 8k 32k 38 4k 46k 48k 50k 56k 56 6k 64k 72k 76 8k 115 2k bit s Pseudorandom pattern PRBS 6 7 9 11 15 19 20 23 RPRBS 20 reversed PRBS20 QRSS positive negative logic Error measurement Progra...

Page 4: ...H3T type plug BNC 2 m for 6M J0921B Measurement cable 8 pin modular ISO10173 M 1PS 2 m for 1 5M 2M J0922B Measurement cable mini BANTAM M 1PS 2 m for 64k 2M CMI J0924B Measurement cable mini BANTAM I 214APS 2 m for external input clock 64k 8k J0930 Measurement cable mini BANTAM M 3912 2 m for 64k Siemens type J0960B Measurement cable mini BANTAM clip 2 m for 64k 2M CMI J0946A Measurement cable 8 p...

Reviews: