Chapter 3 Measurement
3-14
3.6.1 Analysis
Time
Set the continuous measurement period for analysis with a single
capture. Pressing
(Analysis Time) on page 1 of the Modulation
Analysis function menu or
displays the Analysis Time function
menu.
Starting Slot Number
Summary
Sets the starting slot number of continuous measurement period.
Setting range
0 to 14
Measurement Interval
Summary
Sets continuous measurement period in slot.
Setting range
1 to (15
Starting Slot Number)
Example
When 2 is set for the Starting Slot Number and 6 for the Measurement
Interval, measurement between slots #2 and #7 is performed.