Appendix A Specifications
A-4
MU120119A(Cont’d)
Item Specifications
Frame Setting
FCS: CRC32
MPLS label: Up to 10 MPLS labels can be appended.
Fixed
setting.
Protocol Editing: None, IPv4, TCP/IPv4, UDP/IPv4,
IGMP/IPv4, ICMP/IPv4, RIP/UDP/IPv4,
DHCP/UDP/IPv4, IPv6, IS-IS
IPv4/IPv6: IP Destination/Source Address can be set
Fixed, Increment, Decrement, Random
Independently.
*2
TCP/UDP: Either Destination Port Number or Source
Port Number can be set Increment, Random.
Data Field: Can set any portions of Data Field as All 0,
All1, Alternate1/0 (Each bit, Each 2bit, Each
4bits, Each 1 byte, Each 2 bytes), Increment,
Decrement, Random, Single PRBS9.
Only Data Field 1 can set Programmable, Time Stamp
*3
,
Sequence Number
*3
Test Frame.
Programmable Header Pattern: 1 user defined Pattern
can be set.
Frame Size
8 to 65,535 byte
Settable as Auto, Fixed, Increment
*4
or Random
*4
*2: For IPv6, any Increment, Decrement, or Random setting can be
specified for bit widths 1 to 32. Also, only either the destination or
Source Address can be selected.
*3: When a sequence number or Time Stamp is used, the checksum
field of the TCP/UDP packet contains an error code.
*4: Increment and Random settings can be specified for the Frame Size
only when None is selected for the protocol.