3-4 Commands
Command Directory
3-26
PN: 10370-10374 Rev. F
MG369xC GPIB PM
DF5
Description:
Selects F5-delta frequency sweep mode.
Selects a symmetrical frequency sweep around F5. The width of the sweep is determined
by the Delta Frequency parameter.
Functional
Category:
SWEEP
Example:
SSP; DF5; AUT
Sets step sweep F5-
F with auto triggering.
Related
Commands:
F5
,
DLF
,
DFF
,
DFM
Front Panel Key:
Frequency
| Step Sweep | Frequency Control > | F5 - dF
DF6
Description:
Selects F6-delta frequency sweep mode.
Selects a symmetrical frequency sweep around F6. The width of the sweep is determined
by the Delta Frequency parameter.
Functional
Category:
SWEEP
Example:
SSP; DF6; AUT
Sets step sweep F6-
F with auto triggering.
Related
Commands:
F6
,
DLF
,
DFF
,
DFM
Front Panel Key:
Frequency
| Step Sweep | Frequency Control > | F6 - dF
DFF <value> <unit>
Description:
Opens the delta frequency parameter.
Permits setting the Delta Frequency parameter. The frequency setting is determined by
the frequency range of the particular MG369xC model. The commands, DFM and DLF,
are the same as DFF.
Functional
Category:
PARAMETER ENTRY
Value:
Frequency range of the MG369xC model
Units:
GH, MH, KH, HZ
Example:
F1 3 GH; DFF 100 MH; DF1; SSP; AUT
Sets auto trigger step sweep F1-
F 3 GHz - 50 MHz to 3 GHz + 50 MHz.
Output Command:
ODF
returns the DF frequency value (in MHz) to the controller.
Front Panel Key:
N/A
Summary of Contents for MG369 C Series
Page 2: ......
Page 6: ...Contents 4 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 262: ...A 34 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 264: ...Index 2 PN 10370 10374 Rev F MG369xC GPIB PM ...
Page 265: ......