Command Directory
3-4 Commands
MG369xC GPIB PM
PN: 10370-10374 Rev. F
3-25
D4 <value> <unit>
Description:
Opens the internal pulse delay4 parameter.
Functional
Category:
PARAMETER ENTRY
Value:
30 ns to 167 ms at 100 MHz pulse clock rate; 100 ns to 419 ms at 40 MHz pulse clock rate;
300 ns to 1.6 s at 10 MHz pulse clock rate
Units:
SEC, MS, US, NS
Example:
PMD4; D4 100 US; IP
Turns on internal pulse quadruplet with a 100
s delay before the 4th pulse.
Output Command:
OD4
(
s)
Related
Commands:
IP
,
PMD(x)
,
PTG(x)
Front Panel Key:
Modulation
| Pulse
(internal)
| Wdth/Dly List. . . | Edit Selected
DB
Description:
Decibel (dB) data terminator.
Functional
Category:
DATA TERMINATOR
Front Panel Key:
N/A
DF0
Description:
Selects F0-delta frequency sweep mode.
Selects a symmetrical frequency sweep around F0. The width of the sweep is determined
by the Delta Frequency parameter.
Functional
Category:
SWEEP
Example:
SSP; DF0; AUT
Sets step sweep F0-
F with auto triggering.
Related
Commands:
F0
,
DLF
,
DFF
,
DFM
Front Panel Key:
N/A
DF1
Description:
Selects F1-delta frequency sweep mode.
Selects a symmetrical frequency sweep around F1. The width of the sweep is determined
by the Delta Frequency parameter.
Functional
Category:
SWEEP
Example:
SSP; DF1; AUT
Sets step sweep F1-
F with auto triggering.
Related
Commands:
F1
,
DLF
,
DFF
,
DFM
Front Panel Key:
N/A