7. Indicator of 

Battery 

remain

 

The battery level is 
indicated in the 
upper section of the 
display. 
In accordance with operation hours, the indicator 
lights go out as shown below. 
 

 

This table is tentative value because of the battery 
remains according to variety battery specification.  

 

Indicator 

Battery remain 

 

Over 60% 

 

60〜10% 

 

Under10% 

 

Exhausted Battery

 

     
     

Blinks 

 

This instrument can work for a while after the 
Exhausted Battery sign appears. However, Change 
battery as soon as possible, otherwise satisfactory 
function will not be available. 
 
 
 
 

Battery level 

 

Summary of Contents for HA-400 Series

Page 1: ...e1 INSTRUCTION MANUAL HANDHELD THERMOMETER HA 400 Series 2nd edition March 2004 ANRITSU METER CO LTD 2 4 5 Shimomeguro Meguro ku Tokyo 153 0064 Japan Tel 81 3 3491 9181 Fax 81 3 3493 6792 ...

Page 2: ...oducts is not rechargeable model Under Electromagnetic environment Instrument may measure unstably Please observe the following matters to guard the battery leakage exothermic reaction and ignition Do not throw away the battery cells in the fire and avoid short between electrodes Do not charge or heat Use the specified battery cells Set the battery cells correctly and Remove the battery cells when...

Page 3: ...ake this manual however if there are any error or not clear please contact the place of purchase or us We are not responsible for the consequences of using this product Warranty and After sales Service ANRITSU METER CO LTD ships products after severe company s inspection Should you find any failure resulting from poor material and workmanship or accident during transportation please contact the pl...

Page 4: ...e2 ...

Page 5: ... Hand Strap e8 4 4 Sensor Setting e9 4 5 Soft case e9 5 Operation 5 1 Power ON OFF e10 5 2 Hold e10 5 3 Automatic Power OFF e11 6 Default Configuration e11 7 Indicator of Battery remain e12 8 Error Messages 8 1 Indication of Sensor Burnout e13 8 2 Indication of Over range e13 8 3 Indication of Error e13 8 4 Indication of Exhausted Battery e14 9 Maintenance 9 1 Storage e14 9 2 Case cleaning e14 10 ...

Page 6: ...provided If any of them is missing or out of order please contact the place of purchase or us 1 Main unit 2 Soft case 3 AA size alkaline battery cells 4 Instruction manual 5 Warranty 2 2 Repacking Use the original carton of the instrument for its transportation by mail or car If the original case is not available carefully wrap the instrument in shock absorbing material polystyrene form and the li...

Page 7: ...e5 3 Name of Components 3 1 Name of Components MODEL HA 450 Sensor Input connector LED Display Key switch panel AC adaptor jack Battery housing Hand strap ...

Page 8: ...e6 3 2 Display of all segments Battery Indicator Main Display Hold Auto Power OFF ...

Page 9: ...e a thin stick to lightly press it When the Rest button is pressed operation begins in the same way as power is turned ON and the instrument will be ready for measurement When measurement is not intends after battery change turn power OFF 1 Open the battery housing cover 2 Set battery cells correctly 3 After setting battery cells press the Reset switch 4 Close the battery housing cover completely ...

Page 10: ...o commercial power 100V AC When the AC adaptor is connected during operating the battery the internal battery circuit will be cut OFF as same as Reset Be sure to use the specified AC adaptor The AC adaptor for the HA series is available as an option 4 3 How to Use Hand Stra p Hang the hand strap around the hand to prevent in advertent drop of the instrument ...

Page 11: ...d Forcible insertion will damage the instrument Be sure to check the polarity HA 400 HA 450 4 5 Soft case Use the attached soft case for protection instrument against dirt or flaw In case of the combined use attached Soft case and the AC adaptor please bore the hole at the AC adaptor jack part of Soft case by scissors etc ...

Page 12: ...pear on the display for 1 second and start measurement as shown below Press the key again to turn power OFF 5 2 Hold Press the HOLD key to stop measurement and show the measured Temperature on the display Then HOLD appears on the display Press the key again to return to the normal mode HOLD ...

Page 13: ...turn Power OFF after a certain period time about 5 minutes no key operation Press the key again to return to normal mode 6 Default Configuration When the instrument turns power OFF Reset or Battery exchange some setting will be canceled Default Configuration is below tables Function HOLD Cancel Auto Power OFF Default A OFF ...

Page 14: ...n below This table is tentative value because of the battery remains according to variety battery specification Indicator Battery remain Over 60 60 10 Under10 Exhausted Battery Blinks This instrument can work for a while after the Exhausted Battery sign appears However Change battery as soon as possible otherwise satisfactory function will not be available Battery level ...

Page 15: ...eeds the measurable range during measuring the Over range display appears shown as right If the sensor is almost cut the Over range display sometimes appears Please check the sensor cut if measuring temperature is in the range The over range display does not damage the instrument however the sensor will be exhausted Avoid the sensor to the place in measurable temperature 8 3 Indication of Error Th...

Page 16: ...irect Sunlight Strong vibration High humidity 85 RH or more Hot atmosphere 50 or more Dust corrosive gas or salt Strong electromagnetic field It is recommended to put the instrument in the original case when storing it for a long time 9 2 Case cleaning When the case is dirty lightly wipe it with a cloth slightly impregnated with water or petroleum Do not use thinner or benzene otherwise the case o...

Page 17: ...the plug of the sensor with the instrument again If the senor does not hold in the correct position measurement value does not stable If you measure in the environment of strong electromagnetic field a big motor etc please shield the instruments and the sensor against electrical noise 3 Measurement value error is too big Not acceptable If the thermocouple type of the sensor is not corresponded to ...

Page 18: ...g rate Approximately 300 ms Signal source resistance 500Ω Power supply Battery cells AA 4 pieces or AC adaptor Battery life Approximately 150 h Environmental limit Operation 0 40 0 80 Storage 20 50 0 80 Dimensions 71 W 160 H 35 D mm Weight Approximately 250 g Accessories Soft case Instruction manual Battery cells AA 4 pieces ...

Page 19: ...of reading 0 2 100 0 0 1 0 5 1 200 1200 Measurement range 2 0 1 100 0 500 0 Accuracy 1 resolution 0 1370 0 1 of reading 1 200 1 0 5 of reading 1 K Accuracy 0 1 resolution 0 0 500 0 0 05 of reading 0 2 100 0 0 1 0 5 Accuracy Cold junction compensation 0 2 at 25 10 Temperature coefficient 0 01 of F S 1 2 Indicator range is wider than measurement range approximately 2 5 ...