Chapter 8 Operating Optical Interface
8-6
8.2.2 Optical transceiver types
The recommended optical transceivers are listed in Table 8.2.2-1.
For the specifications of the optical transceivers, refer to A.2 “Optical
Transceiver Module”.
For how to install the optical transceiver, refer to Section 2.8 “Installing
Optical Transceiver”.
Table 8.2.2-1 Recommended Optical Transceivers
Model Name
Wavelength
(nm)
Supported
Optical Fiber
Bit Rate (kbit/s)
G0177A
850
MMF
1062000 to 4250000
G0178A
1310
SMF
155200 to 2670000
G0179A
1550
SMF
155200 to 2670000
G0238A
850 MMF
10312500
G0239A
1310
SMF
9953280 to 10312500
8.2.3 Connecting panel connector and optical transceiver
The Tx Data In connector on the front panel connects to the TX+ of the
optical transceiver module.
The Rx Data Out connector on the front panel connects to the RX + of the
optical transceiver module.
Figure 8.2.3-1 Connection Diagram Between Panel Connector and
Optical Transceiver
TX+
TX–
RX+
RX–
TX Data In
Rx Data Out