2-9
Spectrum Analyzer Level Accuracy Verification
Performance Verification
2-20
PN: 10580-00195 Revision B
S312D MM
24.
Disconnect Sensor A from the Synthesized Signal Generator output.
25.
Connect the power splitter to the Synthesized Signal Generator output and connect Sensor B to one of the
power splitter output connections. Install the 30 dB fixed attenuator to the other power splitter output
connection, and connect Sensor A to the attenuator as shown in
.
26.
Record the new Sensor A reading in column B of
.
27.
Record the Sensor B reading in column D of
28.
Calculate the Splitter/Attenuator Combined Loss by using the following formula, and then record the
result in column C of
:
C = A – B
29.
Calculate the Sensor B Path Power Splitter Loss by using the following formula, and then record the
result in column E of
:
E = A – D
30.
Calculate the desired Sensor B Reading for Test Power Level < –50 dBm by using the following formula:
Desired Sensor B Reading = Test Power Level + C – E
31.
Record the calculated results in
Table A-10, “Spectrum Analyzer Level Accuracy with Power Test
Figure 2-8.
Spectrum Analyzer Level Accuracy Verification Characterization Setup
Sensor B
Sensor A
1870A
Power Splitter
ML2438A Power Meter
MG369XA Source
10 MHz Reference
to rear panel
connector
15NNF50-1.5B
34RKNF50
Adapter
Attenuator
30 dB
Summary of Contents for Site Master S312D
Page 2: ......
Page 10: ...1 4 Replaceable Parts General Information 1 4 PN 10580 00195 Revision B S312D MM ...
Page 48: ...3 7 RTC Battery Information Removal and Replacement 3 8 PN 10580 00195 Revision B S312D MM ...
Page 58: ...Test Records A 10 PN 10580 00195 Revision B S312D MM ...
Page 60: ...Test Fixture Schematics B 2 PN 10580 00195 Revision B S312D MM ...
Page 61: ......