17
High Res.
--- the menu item shows the maximum temperatures of the LED driver/LED module since
the counter was last reset. In order to reset this counter to 0 you have to press and hold the UP
and DOWN buttons and at the at the same time press the ENTER button.
Measuring points: Led- a temperature inside the connected LED module
Board- a temperature inside the ArcPower 48 Outdoor
In
case that LED module does not include temperature sensor, the sign “N/A” will be displayed.
Note: The ambient temperature should not exceed 40°C.
The temperatures can be displayed in either °C or °F units - see option “tEM.U“ in the menu “Pers“.
Sw Ver
---
Software Versions.
Select this function to read the software version of the fixture processors.
6.3 Personality
Use this menu to modify the ArcPower 48 Outdoor operating behaviour.
DMX Pres
---
DMX preset
. Select this menu item to set a desired DMX mode. Please refer to the chapter "DMX
protocol" for detail description of each DMX mode.
DMX In
---
DMX input
.
Use the menu to select mode of receiving DMX signal:
Wired
-
DMX signal is received by means of the standard DMX cable.
Wireless
-
DMX signal is received by means of the inbuilt wireless module (wireless DMX version
only).
Analog 0-10V
--- Analog dimmer. If this option is selected, the dimmer channel can be controlled
via DC voltage (0-10V) connected between pins 1 (data ground) and 3 (Data +) of DMX input of
the fixture (0-data ground, 10V-data +).
Procedure of setting:
1. Set fixture´s channels at desired values (by means of menu item Init Effect Positions “I. Ef.Pos”).
2. Disconnect DMX controller
3. Select option “Analog 0-10V” from menu DMX input
4. Connect DC voltage to the DMX input of the fixture
M FTime
---
Max. Fade time.
Select this menu item to set a desired max. fade time (0-25.5 sec.). This adjusted fade
time influences fade of Red, Green, Blue,White and dimmer during DMX operation:
If time between two receiving DMX values is > than fade time set in the item “M Ftime“, the entire adjusted fade
time will be used.
If time between two receiving DMX values is < than fade time set in the item“M Ftime“, the adjusted fade time will
be reduced to fill entire time between the two receiving DMX values.
e.g “M Ftime“=2sec. and fixture has received Red=0 DMX, after 5 seconds will receive Red=255 DMX. It means, that
red will go to full intensity during 2 seconds.
“M Ftime“=8 sec. and fixture has received Red=0 DMX, after 5 seconds will receive Red=255 DMX. It means, that
red will go to full intensity during 5 seconds. (Max, fade time is reduced from 8 sec. to 5 sec.).
Display.
---
Display adjusting
. This function allows you to change the display settings.
Turn
-
This function turns the display by 180°.
On/Off T
-
This function allows you to keep the display permanent on or turn it off two minutes
after last pressing any button on the control panel.
Contrast
-
Use this function to adjust contrast of the display (0-100%).
Backlight
-
Use this function to adjust backlight of the display (0-100%).