background image

19

DMX Values 

--- Select this function to read DMX values of each channel received by the fixture.

Note: if DMX mode 6 is selected, items  Zone 1-8 colour macro and items Dimmer 1-8 are not displayed.

Software Version

 --- Select this function to read the software versions  of the fixture processors:

 

 

IC1 MB1 - the processor  in the electronic module 1 controls LED zones 5-8.

 

 

IC2 MB1 - EEprom on the electronic module 1.

 

 

IC1 MB2 - the processor in the electronic module 1 controls LED zones 1-4.

 

 

IC1 DS - the main display processor on the front panel of the fixture.

 

 

IC2 DS - the display memory on the front panel of the fixture. 

Product IDS

 --- Select this function to read either the MAC address or the RDM UID figure.

10.3 Personality

Use this menu to modify the ArcPower 384 Rack Mount operating behaviour.

User mode 

--- The ArcPower 384 Rack Mount allows you to recall up to 3 user settings. After switching the 

fixture on for the first time, the User A settings is active. Now all changes made in the “Personality” menu , 

”Fixture Address” menu and the “ Presetting Playback“ menu  from the “Stand-alone setting” are saved to the 

User A settings. If you now select the User B settings, from this moment the changes you makes will be saved 

to the User B settings. After switching the fixture off and on, the User B setting will be active. In this way you 

may use the 3 fixture operating behaviours.

  

User A Settings

  - the function recall the user A settings.

  

User B Settings

  - the function recall the user B settings.

  

User C Settings

  - the function recall the user C settings. 

DMX Preset

 --- Use this function to set desired channel setting. Please refer to the chapter “DMX protocol” for 

a detail description of each mode.

Communication Protocol

 --- Select desired protocol: DMX, Dynet or RS-232.

  

Display Adjusting 

--- This menu allows you to change the display settings.

  

Display Permanent On

 - this function allows you to keep the display permanent on or

 

 

 to turn it off automatically 2 minutes after last pressing any button on the control panel.

  

Display Intensity

 - select this function to adjust the display intensity (1 - min., 10 - max.). 

  

Display Backligh

t - select this function to adjust the display backlight (1- min., 10 - max.). 

  

Display Turned

 -  select this function to turn the display by 180°. 

IR Sensor

 --- Select this function to switch on/off the infra-red remote control.

Init Effect Positions 

--- Use this function to set all effects to the desired positions to which they will move after 

switching the fixture on (if DMX is not being received).

Temperature Unit

 --- Use this menu in order to display the fixture temperatures in desired units: °C or °F.

Balance 

--- Use this menu item to enable (On) or disable (Off) the white balance which is set in the „White colour 

balance“ menu below. If this function is set Off, the ArcPower 384 Rack Mount will use maximum values (255) 

of saturation for red, green and blue colour. This function has to be set on before adjusting a white balance.

White Colour Balance 

--- The menu gives access to the setting of the white balance.

To  set white colour balance.

1. Use a DMX controller or  the “Manual Mode“ menu to set all LEDs on max. saturation.

2. Use the ANS rotary wheel to find the “Personality“ menu.

3. Press the ENTER button.

4. Use the ANS rotary wheel to select the "White Balance Setting“ menu.

5. Press the ENTER button and the "Red“ item will appear on the display.

6. Press the ENTER button and use ANS rotary wheel to set new max. value for the red LEDs.

7. Press the ENTER button to confirm the choice. 

8. Use the ANS rotary wheel to select next colour, "Green“.

9. Repeat steps 6-7 for this channel.

10. Use the ANS rotary wheel to select the last colour, "Blue “ and repeat steps 6-7 for this colour.

Summary of Contents for ArcPower 384

Page 1: ...version 1 6...

Page 2: ...Mount into the rack 7 6 DMX 512 operation 7 7 Ethernet operation 8 8 ArcPower 384 Rack Mount Control menu map 10 9 ArcPower 384 Rack Mount DMX protocol 13 10 Fixture menu 17 10 1 Fixture Address 17 10...

Page 3: ...nstall in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not...

Page 4: ...cordon d alimentation du pi tinement ou pincement particuli rement au niveau des fiches des prises et le point o ils sortent de l appareil Confiez toute r paration un personnel qualifi Une r paration...

Page 5: ...ase use the original packaging if the product is to be transported Please consider that unauthorized modifications on the unit are forbidden due to safety reasons 3 Description of the ArcPower 384 Rac...

Page 6: ...r 384 Rack Mount is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 100 240 Volts The fixture is equipped the cord plug QP 02 but you can use t...

Page 7: ...ck Mount unit 3 Slide the the ArcPower 384 Rack Mount into the rack and secure it in this positione by tightening the 2 screws on each side of the ArcPower 384 front panel Note If the equipment rack i...

Page 8: ...l not lit All modules have to be either RGB or RGBW on one LED output 7 Ethernet operation The fixtures on a data link are connected to the Ethernet network with an Art Net communication protocol The...

Page 9: ...e components are needed A cross cable has to be used 1 3 2 6 3 1 4 8 5 7 6 2 7 5 8 4 All fixtures have to be connected to Ethernet via standard patch cables and a data switch The option Ethernet has t...

Page 10: ...rs Set Alert Period 10 50 300 hours Elapsed time Fixture temperature Current Board 1 Temp Board 2 Temp Max Nonresetable Board 1 Temp Board 2 Temp Maximum Resettable Board 1 Temp Board 2 Temp DMX Value...

Page 11: ...l a n c e Setting Red 0 200 255 Green 0 255 Blue 0 237 255 LEDs Output Current Zone 1 350mA 700mA Zone 8 LEDs Power Limiting Zone 1 On Off Zone 8 Maximum Fade Time 0 1 2 25 5 Default Setting Test Seq...

Page 12: ...nu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 Save Save and Copy Start Step Step1 Step 99 End Step Step1 Step 99 Special Functions Effect Adjustment DMX Values RED LEDs 1 Dimmer Initi...

Page 13: ...ional step 6 0 255 Dimmer 1 Dimmer intensity from 0 to 100 proportional ZONE 2 4 5 5 1 1 7 0 255 Red LED 2 Red LED saturation control 0 100 proportional 5 6 6 2 2 8 0 255 Green LED 2 Green LED saturat...

Page 14: ...4 Green LED saturation control 0 100 proportional 12 15 15 3 3 21 0 255 Blue LED 4 Blue LED saturation control 0 100 proportional 16 16 4 22 0 255 White LED 4 White LED saturation control 0 100 propo...

Page 15: ...LED 6 Blue LED saturation control 0 100 proportional 24 24 4 34 0 255 White LED 6 White LED saturation control 0 100 proportional 35 0 1 15 16 17 55 56 57 95 96 97 134 135 136 174 Zone 6 colour macros...

Page 16: ...colour macros selection No function White tones Blue full Red Green White 0 Red 0 Green up Blue full White 0 Red 0 Green full Blue full White 0 Red 0 Green full Blue down White 0 Red 0 Green full Blu...

Page 17: ...l elements on the front panel The ANS rotary wheel used to move between menu items on the same level or adjusts values The ESC button used to leave menu without saving changes The ENTER button used to...

Page 18: ...ry important for the fixture s life and performance Build up of dust dirt and fog fluid residues reduces the fixture s light output and cooling ability The two items of this menu help you to keep clea...

Page 19: ...otocol DMX Dynet or RS 232 Display Adjusting This menu allows you to change the display settings Display Permanent On this function allows you to keep the display permanent on or to turn it off automa...

Page 20: ...ll go to full intensity during 2 seconds and 3 seconds will stay in full intensity Maximum Fade Time 8 sec and fixture has received Red 0 DMX after 5 seconds will receive Red 255 DMX It means that red...

Page 21: ...is on autocalibration of the fixture will run after switching the fixture on or reset the fixture or changing LED ouput power 300mA 700mA 700mA 300mA Updating Software The menu item allows you to upda...

Page 22: ...connected LED module 1W LEDs 80 metres ProLight Opto 3Watt Proeon LEDs 20 metres ArcPad 48 40 metres connecting cable Igus with Chogori Cogori connectors has to be used DMX control channels Mode 1 24...

Page 23: ...culated 1700 BTU h at 350mA LED outputs 4000 BTU h at 700 mA LED outputs Dimensions mm Weight 9 7 kg Accessories Cable joiner No 13050691 8 pcs Optional accessories Remote control IR No 13050419 Flash...

Page 24: ...m and put back dry 5 Put the filters cover back to the protective grid and secure them by he filter holding section 6 Screw up the protective grid 1 to the front panel 7 Repeat the same procedure for...

Page 25: ...25...