Annovi Reverberi AR 50 Instruction Manual Download Page 4

Control Unit

 GI40 & GIC40

GI40 and GIC40 

Control Units:

Control  units  are  available  for  easy  flow  and  pressure  control 

of  your  sprayer  system.  These  units  include  a  manual 

dump  valve  and  adjustable  pressure  relief  valve  to  control 

pressure, a  liquid-filled  pressure  gauge  to  monitor  pressure, 

and  shut-off valves  to control flow.

On  pump

s

  AR30  and  AR40,  adjust

the  pressure by  clamping  the

relief  valve  adjustment  lever

down.

With  the  bale  hook  in  the  number

one position,  the  pressure  is  about

100  psi;  number two is about 250

psi; number three is about 450 psi;

number  four  is  about  550  psi.

These pressures  can  be  adjusted

by  using  the  fine adjustment  knob

located  on  top  of  the  relief valve

spring.  The  fine  adjustment  knob

can  be rotated  when  the  relief

valve  lever  is  in  the  up position.

On  pumps  AR30  and  AR40,  the

pressure

  is 

released

 by lifting up

the relief valve adjustment lever

with  the  bale  hook  on  the

number  1 position.

Pressure

 Adjustment & 

Release Lever

 

Fine

 Adjustment Knob

 

Pressure 

Gauge

Bypass Return Outlet

 

(Connect directly to the 

tank without restrictions 

or ball valves.)

Hose

 Barb Outlet

  

  2 Places

 

Control Unit Operation

Summary of Contents for AR 50

Page 1: ...80 40 65 8 580 40 65 8 580 40 WEIGHT HP POWER LBS 5 2 39 3 5 2 39 3 5 2 50 0 diAPHRAgm KiTS modeL deScRiPTion AR43293 BlueFlex AR43291 Desmopan AR43290 Buna VALVe KiTS modeL deScRiPTion AR1920 Valves...

Page 2: ...AR43388 r mo AR4338 del A 50 0 fo AR43390 r mo AR4339 del A 503 AR303 AR403 Kit includes a male 1 keyed shaft adapter mounting bracket and necessary hardware AR43397 For models AR30 AR50 AR303 AR403...

Page 3: ...o not draw in liquids at temperatures above 50 C or below 5 C Do not use the pump in drinking water supply systems Do not use the pump on products for human consumption Do not use the pump on pharmace...

Page 4: ...n the pressure is about 100 psi number two is about 250 psi number three is about 450 psi number four is about 550 psi These pressures can be adjusted by using the fine adjustment knob located on top...

Page 5: ...g a vacuum gauge to the pump intake fitting The rated pressure of the outlet hose fittings and clamps must be no less than the maximum rated pressure ofthe pump Replacing the intake and outlet fitting...

Page 6: ...implified illustration of the typical installation layout and is purely guideline Control Unit by pass Tank Agitation plugged strainer or too small a strainer Control Unit Pump Intake filter Delivery...

Page 7: ...see Technical Data free from restrictions and elbows and with a filter of suitable capacity see Installation For occasional duty such as filling water supply tanks the pump can be operated at a vacuum...

Page 8: ...issing ordamaged contact the dealer or manufacturer to agree the procedures to be followed The packaging material must be disposed of appropriately in accordance with the relevant statutory require me...

Page 9: ...ed in the Checking the oil level section Before putting the pump into operation check that the control unit is set for low pressure with the adjustment lever released Starting and stopping the pump To...

Page 10: ...rtridge See Inspecting the filter Pump Checking the oil level See Checking the oil level Connection of pump to power Inspection Every working day source pulley belt coupling Pump Inspect mounting See...

Page 11: ...Inspecting the Filter Inspect the filter cartridge If the cartridge is fouled wash it thoroughly to remove the dirt If the cartridge is torn or cracked it must be replaced Checking the oil level Check...

Page 12: ...ted with a pressure gauge The ac cumulator is inflated by the manufacturer for use of the pump at its maximum pressure For adap tation of the accumulator pressure to the working pressure refer to the...

Page 13: ...tention inside the pump of products which are often corrosive and may damage its liquid circuit over the long term If thepump is instorageduring the winter in locations with severe weather conditions...

Page 14: ...Restriction in intake circuit Intake filter fouled Intakecircuit not airtight Residual air left inside pump Valve plate stuck to its seat Pressure accumulator deflated Pressure accumulator deflated R...

Page 15: ...t worn Oil pressure inside pump too high Restore correct oil level in tank One or more diaphragms ruptured Stop the pump at once Replace the diaphragms 1 Oil on pump body or base Pumpusing too much oi...

Page 16: ...8 27 26 24 84 74 3 66 67 25 46 70 72 71 38 69 50 49 48 47 45 43 40 39 41 42 28 28 73 28 60 10 11 9 65 12 14 13 14 16 16 15 5 6 7 8 17 64 63 34 68 33 32 31 30 21 18 19 20 22 23 AR 50 659209 no longer a...

Page 17: ...g 29x3 1 Pos Code Description Qty Note 46 650150 Manifold 1 47 450120 Fitting 1 G 1 1 4 G M M 1 48 390290 O ring 29x3 1 49 580060 Ring nut 1 1 4 G 1 50 580040 Elbow 1 1 4 1 51 650250 Key 1 For650171 5...

Page 18: ...Gasket 1 390141 Gasket 1 Viton 15 550380 Elbow 3 4 1 GIC40 550460 Elbow 3 4 1 GI40 16 550440 Fitting 1 2 G 3 4 G M M 1 17 320410 Body valve 1 18 320480 Hub pin 2 19 320460 Fork 1 20 320470 Lever 1 21...

Page 19: ...0 S AR 977 I Build in control Pos Qty Pos Qty 15 1 31 1 36 1 39 2 For AR 30 AR 50 AR 303 AR 403 AR 980 S Remote control Pos Qty Pos Qty 3 1 4 2 6 1 15 1 28 1 30 1 31 1 32 1 33 2 36 1 39 3 For AR 30 AR...

Page 20: ...10 4 14 15 16 15 17 18 19 11 Per For AR 30 AR 303 AR 403 Pos Cod Description Q ty Note 1 620561 O ring 78x2 5 1 2 180030 Bolt TCEI M8x20 1 T220 3 621000 Adapter Flange 1 4 620990 Bearing 1 5 651620 Ge...

Page 21: ...I M10x75 4 T220 13 1140370 Plug 1 14 651610 Pinion Z 11 1 15 320240 Ring circlip e 40 2 16 961780 Bearing 1 17 961790 Ring circlip i 68 1 18 961800 Oil seal 1 19 651000 Bolt 5 16 x24UNFx1 4 GeometT220...

Page 22: ...0 Bearing 1 4 2960050 Bolt 5 16 24UNF2B 1 T177 5 2960020 Body 1 6 740290 O ring 14x1 78 4 7 1980740 Plug 3 8 Gbrass 1 8 390450 Bolt M8x30 6 T177 9 2960070 Plug 1 10 2960060 O ring 177 47x2 62 1 11 138...

Page 23: ...60130 Hubpin M8 7 16 24UNF 1 2960140 Hubpin M8 M8 1 19 1121160 O ring 6 86x1 78 3 20 2960100 Pinion Z 14 1 1 21 1660210 Nut M8 1 T177 22 160671 Bolt M10x25 4 T221 23 1220260 Bearing 1 24 2960010 Cover...