Annovi Reverberi AR 160 LFP Instruction Manual Download Page 14

2021 AR North America

35

Lo

w pr

essur

e

C/C

BlueFlex

TM

AR160LFP

31484

AR185LFP

33125

AR 160 LFP / AR 185 LFP

Pos

Code

Description

Qty

Note

1

761031 Base

2

2

160673 Bolt

TE M10x25

6

SS T354*

3

761010 Pump body

1

4

880530 Plug

3/8" G

1

T177*

5

740290 O-ring

Ø 14x1.78

1

6

3460020 Head

4

7

750072 Bolt

TE M12x70

16

SS T309*

8

390092 Washer

16

SS

9

750040 Gasket

1

10

751170 Oil sight glass

1

11

1980340 O-ring

Ø 83.8x2.62

1

12

751183 Cap

Red

1

13

380243 Washer

2

14

680350 Bolt

TCEI M8x35

2

T88*

15

2429051 Valve

AISI 316L

8

16

3460380 Gasket

8

Viton

17

3460201 Bolt

TE M8x100

16

SS T88*

18

390315 Washer

16

SS

26

761240 Manifold section

1

27

1150641 O-ring

Ø 20x24x2.62

2

Viton

28

3460490 Plug

1/2" G

2

T88*

29

230061 O-ring

Ø 34.52x3.53

32

Viton

30

3460210 Fork

1

31

761250 Fork

16

32

761200 Manifold section

4

33

761190 Manifold section

7

34

761230 Manifold section

air chaimber

1

35

761191 Manifold section

SRV port

1

36

761220 Manifold section

discharge 1-1/2" G

1

37

1880460 O-ring

Ø 29x3

1

Viton

38

750670 Ring nut

1-1/2" G

1

39

3040160 Elbow

Ø 35

1

40

3460180 Semi air chamber

lower

1

Nylon

41

800192 Diaphragm

air chaimber

1

BlueFlexTM

42

3460190 Semi air chamber

upper

1

Nylon

43

650542 Gasket

1

44

180020 Air valve

1

T22*

45

390315 Washer

12

SS

46

621782 Bolt

TE M8x40

6

SS T177*

47

3120260 Nut

M8

6

SS T177*

48

3120510 Nut

famework M8

16

SS

49

880311 O-ring

Ø 26.65x2.62

2

Viton

50

761210 Manifold section

inlet 2" G

1

51

3040471 O-ring

Ø 39.34x2.62

2

Viton

52

3040450 Ring nut

2" G

1

53

3040440 Elbow

Ø 50

1

54

760140 Connecting-rod

4

55

160700 Pin

4

56

160691 Ring

Øi 18

8

57

550081 Diaphragm

4

BlueFlexTM

58

750122 Piston

Ø 80

4

59

500260 Piston ring

4

Pos

Code

Description

Qty

Note

60

750115 Sleeve

4

AR160LFP

61

751251 Retaining washer

4

62

2240670 Nut

M10 AISI 316L

4

T221*

63

2240101 Hub pin

AISI 316L

4

(a) T265*

64

1500470 Shaft protection

1

65

850252 Bolt

TCEI M8x12

3

SS T88*

66

390315 Washer

3

SS

67

200390 Ring

Øi 62

2

68

160740 Ring

seal

2

69

680020 Support

1

70

851360 O-ring

Ø 120.32x2.62

1

71

230350 Bearing

1

72

160673 Bolt

TE M10x25

6

SS T309*

73

540040 Retaining washer

2

74

750130 Ring

piston rod

2

75

750090 Bearing

2

76

750174 Shaft

C/C m-AV

1

AR160LFP

85

43067 Air chamber

LFP BlueFlexTM

1

(a)  Bolt Shank piston side with Loctite 242 Strong threadlock (Green) and lubricate the shank side Retaining washer with 

Molykote grease 1000.

* Torque: in-lbs +/- 10%

Suggested oil

Type

Oz

AR64532D

32

AR 43169 

Valves

Pos.

Qty

15

8

16

8

Pump and 
manufacturer 
identification.

2154700 Air chamber decal

Crankcase Oil 
Capacity  56 oz

AR 43259 

BlueFlex diaphragms

Pos.

Qty

9

8

30

4

52

1

AR 43170 

O-Rings

Pos.

Qty

Pos.

Qty

5

2

61

1

9

8

65

2

16

1

69

1

21

1

74

1

25

2

53

1

Summary of Contents for AR 160 LFP

Page 1: ... weigHT LBS AR160LFP C C 43 9 166 2 220 15 6 8 55 1 AR185LFP C C 48 1 182 1 220 15 7 4 55 1 diAPHRAgm KiTS modeL deScRiPTion AR43259 BlueFlex AR43257 Desmopan AR43256 NBR AR43258 Viton VALVe KiTS modeL deScRiPTion AR43169 Valves o Ring KiTS modeL deScRiPTion AR43170 O Rings oiL modeL deScRiPTion AR64532D Oil AR64532D C Case 6 Oil 140 F Max Water Temp 2 Suction 1 1 2 Outlet ...

Page 2: ...Do not draw in liquids at temperatures above 50 C or below 5 C Do not use the pump in drinking water supply systems Do not use the pump on products for human consumption Do not use the pump on pharmaceutical products Do not use the pump without first checking that the intake and delivery circuit pipelines are correctly secured and free from leaks Do not use the pump without the safety devices prov...

Page 3: ...n diagram guideline The following is a simplified illustration of the typical installation layout and is purely a guideline Control Unit by pass Control Unit Delivery line filter Tank Agitation Pump Intake filter ...

Page 4: ... see Technical Data free from restrictions and elbows and with a filter of suitable capacity see Installation For occasional duty such as filling water supply tanks the pump can be operated at a vacuum drawing in liq uids from reservoirs having the surface of the liquid up to 5 m below the pump intake fitting for periods of no more than 15minutes Drawing in liquids from lower levels or for longer ...

Page 5: ...missing ordamaged contact the dealer or manufacturer to agree the procedures to be followed The packaging material must be disposed of appropriately in accordance with the relevant statutory require ments Transport The pumpmay be shipped by a variety ofmeans oftransport road rail sea or air depending on itsdestination Secure the packaging firmly to the vehicle duringtransport to preventrandom move...

Page 6: ...ng a vacuum gauge to the pump intake fitting The rated pressure of the outlet hose fittings and clamps must be no less than the maximum rated pressure ofthe pump Replacing the intake and outlet fittings provided onthe pumpby the manufacturer withsmaller diameter alternatives may reduce the pump s performance and void the warranty Mounting the pump The pump must be installed on a horizontal surface...

Page 7: ...level as described in the Checking the oil level section Before putting the pump into operation check that the control unit is set for full bypass Starting and stopping the pump To start the pump proceed as described below 1 When starting the pump keep the control unit in the full bypass position until the pump has primed 2 After starting the pump and after the pump is primed move the control unit...

Page 8: ...artridge See Inspecting the filter Pump Checking the oil level See Checking the oil level Connection of pump to power Inspection Every working day source pulley belt coupling Pump Inspect mounting See Inspecting the pump mounting Pipes and connections Inspection See Inspecting the connections and pipes Pressure accumulator if in Check inflation pres See Checking the Every 100 working stalled sure ...

Page 9: ...eplaced Inspecting the Inlet Filter Inspect the inlet filter cartridge If the cartridge is fouled wash it thoroughly to remove the dirt If the cartridge is torn or cracked it must be replaced Checking the oil level Check the oil with the pump level ensuring that it has been running for at least 5 minutes in normal working conditions If the oil level is not visible or completely full add or remove ...

Page 10: ...the pump of products which are often corrosive and may damage its wetted parts over the long term If thepump is instorageduring the winter in locations with severe weather conditions it is very important to flush out the internal circuit as described above and then fill the pump with A R Pump Saver AR64511 Then take care to drain the liquid from the system and the pump Putting the pump back into s...

Page 11: ...r Restriction in intake circuit Intake filter fouled Intakecircuit not airtight Residual air left inside pump Valve plate stuck to its seat Pressure accumulator deflated Pressure accumulator deflated Restriction in intake circuit Intake filter fouled Pump drawing in liquid from too low a level Remedy Tighten repair or replace hoses and fittings as necessary Move control switching leverto By pass s...

Page 12: ...ft worn Oil pressure inside pump too high Restore correct oil level in tank One or more diaphragms ruptured Stop the pump at once Replace the diaphragms 1 Oil on pump body or base Pumpusing too much oil oil flowing from delivery port or oil whitish in color water oil emul sion in tank ...

Page 13: ... 49 29 34 29 33 35 15 16 29 32 16 33 29 28 28 27 27 31 30 29 17 18 48 16 15 33 29 26 31 15 7 8 4 5 6 1 3 1 6 6 7 8 9 13 14 12 6 11 10 2 51 51 52 53 32 29 33 31 29 29 33 29 50 29 33 31 29 32 17 29 33 32 15 16 48 18 65 66 67 64 68 72 69 70 71 73 74 75 76 75 74 73 71 68 67 Version 56 55 54 58 59 63 60 57 61 62 AR 160 LFP C C AR 185 LFP C C ...

Page 14: ...2 45 390315 Washer 12 SS 46 621782 Bolt TE M8x40 6 SS T177 47 3120260 Nut M8 6 SS T177 48 3120510 Nut famework M8 16 SS 49 880311 O ring Ø 26 65x2 62 2 Viton 50 761210 Manifold section inlet 2 G 1 51 3040471 O ring Ø 39 34x2 62 2 Viton 52 3040450 Ring nut 2 G 1 53 3040440 Elbow Ø 50 1 54 760140 Connecting rod 4 55 160700 Pin 4 56 160691 Ring Øi 18 8 57 550081 Diaphragm 4 BlueFlexTM 58 750122 Pisto...