background image

                                                                  

 

                   

 

                 

 

 

 

 

 

●    Do

 not drop or abuse the tool.   

●    Whenever a tool is not bein

g used, position the Power Switch to the “OFF” position and unplug the power cord. 

 

 

 

 

 

 

 

 

 

Attaching / detaching bit and bit type   

Push up the holder clamp by finger tip, and it will be unlocked. Thus, the bit can be freely attached and detached (single finger 

notion type) select such a bit whose shank is equal to the size shown below.         

 

 

 

 Insert the power plug into a receptacle and set the changeover switch to “

F

 

position. 

 Apply the bit to the screw head and press the lever or push main body to, then the switch will be turned ON to start the motor 

running. 

 When the screw is tighten and reach the torque that you had set, The tool will stopped automatically. 

 To reset the tool by releasing the lever to the original position or releasing the bit From the screw head.   

 To return the screw, set the changeover switch to “

R

” position. 

 

Hi/Lo Switch 

 

When the TR0206 Series rotating speed needs to be changed, set up the switch to Hi for the fastest rotation, and set 

up the switch to Lo for slowest rotation. It's possible that the uncompleted shut-off occurs when the switch is setup to Lo and the 

presetting torque is more than 50% of torque range. Please refer to the following table. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lo Switch 

MY9- 

0206L 

MY9- 

0309L 

MY9- 

0612L 

MY9- 

0206LF 

MY9- 

0206P 

MY9- 

0309P 

MY9- 

0612P 

MY9- 

0206PF 

OK 

3( N.m )↓

 

4.5( N.m )↓

 

6( N.m )↓

 

3( N.m )↓

 

3( N.m )↓

 

4.5( N.m )↓

 

6( N.m )↓

 

3( 

N.m )↓

 

NG 

3( N.m )↑

 

4.5( N.m )↑

 

6( N.m )↑

 

3( N.m )↑

 

3( N.m )↑

 

4.5( N.m )↑

 

6( N.m )↑

 

3( 

N.m )↑

 

       Description of Operation   

CAUTION 

Summary of Contents for MYTORQ MY9-0206L

Page 1: ...gh torque series For safety consideration please collaborate it with Auxiliary Arm KP AUXA2 DC TYPE Automatic Non Carbon Brush Series ANLIDAR INDUSTRIAL CO LTD http www anlidar com Y2F182A 3E 002 MY9 0206L MY9 0206LF MY9 0309L MY9 0612L MY9 0206P MY9 0206PF MY9 0309P MY9 0612P ...

Page 2: ...tion enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manual into the hands of the operator Failure to observe the following warnings could result in injury When using electric tools Basic safety precautions should always be followed to reduce the risk of ...

Page 3: ...equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Rubber gloves and non skid footwear are recommended when working outdoors c Avoid accidental starting Ensure the switch is in the off position before plugging in Carrying power tools with your finger on the switch or plugging in power tools that have the sw...

Page 4: ...epair person using only identical replacement parts this will ensure that the safety of the power tool is maintained Additional information shall be provided a Instruction for putting into use 1 Setting up or fixing power tool in a stable position as appropriate for power tools which can be mounted on a support 2 Assembly 3 Connection to power supply cable fuse socket type and earthing requirement...

Page 5: ...t important task a user Periodically depends on the working condition and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm Touching 2 test rods together and reset the meter to 0 Using the Red rod to touch the Grounding wire on the Plug of controller s cord...

Page 6: ...ically the power will shut off and the motor breaks immediately the screwdriver stop running 8 Trigger Start Type screwdriver When loosen a fastened screw please set Forward Reverse switch to Reverse If the screw is reversed thread screw please set Forward Reverse switch to Forward Follow the above operation after loosening the screw release the trigger to stop Push Start Type screwdriver When loo...

Page 7: ... and reach the torque that you had set The tool will stopped automatically To reset the tool by releasing the lever to the original position or releasing the bit From the screw head To return the screw set the changeover switch to R position Hi Lo Switch When the TR0206 Series rotating speed needs to be changed set up the switch to Hi for the fastest rotation and set up the switch to Lo for slowes...

Page 8: ...labels Replace any damaged label 1 The use of other than genuine MYTORQ replacement parts may Result in decreased tool performance and increased maintenance and may invalidate all warranties 2 All repairs and maintenance of this tool and its word must be performed by an authorized service center 3 Anlidar is not responsible for customer modification of tools for applications on which Anlidar was n...

Page 9: ...MY9 0206LF MY9 0309L MY9 0612L MY9 0206P MY9 0206PF MY9 0309P MY9 0612P Input voltage DC DC 40V Power Consumption 150 150 150 150 Torque N m hard joints 2 6 2 6 3 9 6 12 soft joints 80 2 4 8 2 4 8 3 7 2 4 9 6 Repeatable Torque Accuracy 5 Torque Adjustment Stepless Unloaded Rotation Speed R p m 10 1000 2200 1000 880 Screw Size Dia Machine screw mm 4 0 5 0 4 0 5 0 5 0 6 0 8 Tapping screw mm 4 4 4 5 ...

Page 10: ...of screwdriver The clamping torque of screw itself is different from the clamped conditions Understand the correlation between clamping torque values and the torque checker values perform the torque control properly 1 Please read the operation caution carefully before using our screwdriver and follow the safety information to use this power supplier 2 This model screwdriver must work with 6PIN pow...

Reviews: