Anjon BFED4200 Operation Manual Download Page 4

These pumps are designed as submersible pumps and have been 
provided with overload protection for use in garden ponds, fountains, 
terraced fountains, indoor fountains to circulate and oxygenate clear 
water. You can use the suction cups or four screws to fix it. If it is 
fixed to any appropriate bases, make sure that the appliance is 
securely installed before operating it.

 

 

Facts

 

 

High performance asynchronous motor with new design

 

 

Energy saving up to 50% more than other pumps.

 

 

High pump heads and larger flow.

 

 

Can pump dirt particles of size up to ¼”

 

 

Wear proof ceramic shaft which can be used for a longer period 

of time.

 

 

Used as submersible pumps (see fig.1)

 

IMPORTANT

:  Do  not  let  the  pump  run  dry  –  this  could  cause 

damage to the motor.

 

 

Submerse the pumps completely in your skimmer so as to make 
the pump body fill with water.

 

 

A water level of approx. 6 in. is required for submersible use in 
order to prevent the pump from taking in air. (See fig.1)

 

 

To prevent the screen becoming prematurely clogged, place the 
pump above the mud in the pond!

 

 

The  pump  is  designed  to  accommodate  2”  external  threads 
through  the  socket  (fountain  jets,  nozzles,  water  height 
regulators, standpipes, etc.).

 

 

Running  in  conjunction  with  fountain  jets,  the  pump  should  be 
stationed firmly and horizontally (on a brick). 

 

 

The  pump  can  be  switched  on  by  simply  plugging  it  in  and 
switched off by plugging off.

 

 

The  water  temperature  should  not  exceed  35

  (95

)  and  do 

not let the pump freeze in the wintertime.

 

 
 
 
 
 
 
 
 

Overload protection

 

The pump has a built

-

in thermal overload trip which prevents the pump from 

overheating. The pump must be allowed to cool down before restarting. 

 

If  the  pump  will  not  start  again  automatically  when  cooling  down,  please 
check the following conditions:

 

 

Is there a sufficient water supply?         

add water if necessary

 

 

Has the screen become clogged?         

Clean it if necessary

 

 

 

Has  dirt  entered  the  pump  housing?               

follow  the  cleaning 

instructions below

 

 

Have hoses or jets become clogged?         

clean them if necessary

 

 

Has the pump sufficiently cooled down after overheating?

 

 

As soon as you have completed this checklist, you can start the pump 
again by plugging it back in.

 

 

Maintenance and cleaning (see fig2)

 

1. 

Follow these safety instructions. Make sure that the pump is unplugged.

 

2. 

Loosen the 3 screws (1) and remove the lower screen (2).

 

3. 

Loosen the 4 screws (3), and remove the pump house (4) and hoop (9). 

 

4. 

Turn the pump house cover (7) in Anti

-

clockwise direction; remove the 

pump house cover (7) from the pump body (8).

 

5. 

Take the impeller assembly (5) out from the pump body (8).

 

6. 

Clean all parts using water and soft sponge.

 

7. 

For hard water deposits or rust, use a solution of CLR (or like product) 

 

with water (1:4 ratio is recommended).

 

 

Assembling the pump together:

 

Place the impeller assembly (5) pump body (8) with caution.

 

2.   Make sure the impeller assembly (5) is assembled correctly and will turn 

freely and check the position of the sealing ring (6) on the pump body 

(8).

 

3. 

Turn the pump house cover (7) in a clockwise direction. Put the pump 

house cover (7) in the pump body (8) 

 

4. 

Move the hoop (9) in the correct position and assemble the pump house 

(4). Tighten the 4 screws (3) uniformly.

 

5. 

Assemble the lower screen (2) and tighten the 3 screws (1) uniformly.

 

Reviews: