Anjon AFF10100 Owner'S Manual Download Page 3

3

PUMP AND FOUNTAIN SPECIFICATIONS

MS-10000

MS-12500

Pond Size (surface acres)

Up to 1

Up to 1¼

Range of Fountain Pattern Heights (feet)

7-25

7-28

Range of Fountain Pattern Widths (feet)

4-28

5-35

Minimum Operating Depth

20"

20"

Max Flow (gph)

10,000

12,500

Watts (120v)

1000

960

Amps

8.3

8.0

Volts

120

120

Cord Length (ft.)

100, 200

100, 200

Dimensions l x w x h

12" x 9" x 9"

15" x 8" x 9"

Pump Weight (lbs.)

29

30

Please read all instructions thoroughly and understand them 

prior to installation or use. If you have any questions or are 

missing pieces, do not contact or return to place of purchase; 

please call 

1-800-553-5605

.

CONTENTS PAGE

Components 4

Nozzle Assembly 

4

Optional Light Assembly 

5

Optional Accessories 

5

Mooring Rope Assembly 

6

Warranty Info 

7

SAFETY INSTRUCTIONS

•  Read and observe all the instructions supplied with the pump and on the pump.

•  Make sure that your outlet voltage corresponds to those stated on the rating label of the pump(s).

•  Make sure the pump is securely installed before operating it.

•  The electrical connection should be in a water-proof area and should be at least 6 feet away from the edge of the pond. (see fig. 3)

•  Keep the electrical connections dry! Hang the electrical cord below the electrical outlet to form a "Drip Loop". This will prevent water from 

running down the cord into the electrical outlet

•  Always unplug the pump when not in use, before putting on or taking off parts, before cleaning the pump and before doing any work  

for the fountain or pond.

•  The pump must not be used when people are working in water. Please disconnect the pump first.

• Do not operate any appliance with a damaged cord or plug, or in abnormal state. The supply cord of the pump cannot be replaced. 

• If the cord is damaged the pump should be discarded. Replacement pumps are readily available.

• Do not cut the plug end off the cord for any reason. Cutting the cord voids the warranty and may create an electrical hazard.

•  For safety reasons, routine cleaning, maintenance or repair work should only be done with the power cord disconnected from  

the power source.

• Never hang or transport the pump by means of pulling the power cord!

• Close supervision is necessary when the pump is used by or near children.

• To disconnect the pump from the power source, pull the plug by the molded end; never pull the plug by the wire.

•  Never use any accessories which are not recommended by the pump manufacturer. This may result in fire, electric shock, personal injury 

and/or voided warranty.

•  The pump is to be supplied through a Ground Fault Circuit Interrupter (GFCI) with a rated residual operating current not  

exceeding 30mA.

• To protect against the risk of electrical shock, do not immerse the plug in water or other liquid.

• Do not plug the pump in out of water, doing so damages the pump and voids the warranty

• The pump power cable needs to be ran through conduit from your water feature to the GFCI.

• Do not fish around the fountain, this can damage the power cord.

• If running in winter be careful of thin ice; the fountain will keep the ice thin and dangerous to walk on.

•  Use extreme caution when operating fountain in cold weather and cold water. Do not walk on ice. Thin ice will break, creating the  

risk of hypothermia or drowning.

800-553-5605 • www.anjonmfg.com

Making a Difference

800-553-5605 • www.anjonmfg.com

Making a Difference

Summary of Contents for AFF10100

Page 1: ...OWNER MANUAL MONSOON FLOATING FOUNTAIN 800 553 5605 www anjonmfg com MS FA 10 12...

Page 2: ...nchronous drive motor can be controlled with variable speed controller not included that permits you to increase or decrease pump flow as needed Vortex impeller passes solids to 25 Engineered for 24 h...

Page 3: ...t the pump first Do not operate any appliance with a damaged cord or plug or in abnormal state The supply cord of the pump cannot be replaced If the cord is damaged the pump should be discarded Replac...

Page 4: ...SEMBLY FIG 1 1 Place pre assembled parts under the float through the center 2 Slip the Nozzle Quick Release down over the nozzle and twist it to lock into place 3 Select and install nozzle Do not over...

Page 5: ...nd the lights will change colors and modes along with the music Also use the timer function to automatically turn the lights off when you will not be home to enjoy your feature Your floating fountain...

Page 6: ...your liner Make sure the ropes are secure to the float Important Always retrieve the fountain using mooring ropes Never retrieve with the power cord FIG 3 1 Securely attach mooring ropes not included...

Page 7: ...ervice under this warranty will be accepted if received more than 30 days after the term of the warranty Correction of defects in the manner and for the duration of the warranty described in this warr...

Page 8: ...mfg com E mail sales anjonponds com Making A Difference Register Products Online Review Maintenance Service Advice Design Build Tips in the Knowledge Center Check Out the Full Line of Anjon Products 8...

Reviews: