background image

2015/04 Rev. 2.0

TVB100

10

GB

WARNING

•  Stay with the machine during the descalling process and clean the

 

  machine.

•  When descaling, always follow the instructions of the descaling agent used.
•  When using a descaling agent it is advisable to wear protective gloves 

 

  and safety goggles. 

•  Allow the machine to operate with clean water at least twice to rince

 

   the solution from the system.

•  After descaling, wash your hands thoroughly.
•  If the machine is not being used it is advisable to disconnect the

 

  appliance.

     

8.  DESCALING

Switch off the cold water heater and wait until the water in the water heater 

has become cold so that the blend tray can be easily removed. As soon as 

the TVB100 has cooled down, remove the lid (fig. 8A) from the reservoir 

and lift the blender (fig. 8B) from the water heater. The whole boiler 

will now be visible. Tilt the TVB100 (fig. 9) to empty the water together 

with possible loose scaling. For removing the rest of the scaling use 

“ANIMO” descaling agent. Prepare an acid solution of  ± 3 tablespoons of 

powder per one litre ± 60-70°C. 

The blender cannot be cleaned with a 

descaling agent, as it is not acid resistant

.

Pour the solution into the machine to just below the syphon and leave for 

a while. Place an empty slide-in filter (fig. 1B) in position and an empty 

thermos jug below it. Pour one measuring jug of water into the water 

heater so that the solution is drained from the water heater through the 

syphon. Then the water heater can be emptied. Put the blender into the 

water heater with the arrow pointing in the direction of the filter. Replace 

the blender in the water heater and fill up the TVB100 with water as 

described in section 5 (PREPARATIONS BEFORE USE). Allow the 

machine to operate with clean water at least twice to rince the solution 

from the system.

9.  BREAKDOWN ANALYSIS

The TVB100 does not heat up the water. The water remains cold while the 

switch for activating the water is on.

9.1  CAUSE AND SOLUTION

-  The dry heating protection device is switched off.

  The TVB100 is fitted with a dry heating protection device that can 

  be reached externally at the back (fig. 10A). Remove the protective  

  cover and press the button. The element will then be switched on again. 

-  If a breakdown is not caused by the dry heating protection device, 

  consult your dealer.

 

TVB10

0

fig. 9

A

fig. 10

A

B

fig. 8

Reviews: