2015/04 Rev. 2.0
TVB100
10
GB
WARNING
• Stay with the machine during the descalling process and clean the
machine.
• When descaling, always follow the instructions of the descaling agent used.
• When using a descaling agent it is advisable to wear protective gloves
and safety goggles.
• Allow the machine to operate with clean water at least twice to rince
the solution from the system.
• After descaling, wash your hands thoroughly.
• If the machine is not being used it is advisable to disconnect the
appliance.
8. DESCALING
Switch off the cold water heater and wait until the water in the water heater
has become cold so that the blend tray can be easily removed. As soon as
the TVB100 has cooled down, remove the lid (fig. 8A) from the reservoir
and lift the blender (fig. 8B) from the water heater. The whole boiler
will now be visible. Tilt the TVB100 (fig. 9) to empty the water together
with possible loose scaling. For removing the rest of the scaling use
“ANIMO” descaling agent. Prepare an acid solution of ± 3 tablespoons of
powder per one litre ± 60-70°C.
The blender cannot be cleaned with a
descaling agent, as it is not acid resistant
.
Pour the solution into the machine to just below the syphon and leave for
a while. Place an empty slide-in filter (fig. 1B) in position and an empty
thermos jug below it. Pour one measuring jug of water into the water
heater so that the solution is drained from the water heater through the
syphon. Then the water heater can be emptied. Put the blender into the
water heater with the arrow pointing in the direction of the filter. Replace
the blender in the water heater and fill up the TVB100 with water as
described in section 5 (PREPARATIONS BEFORE USE). Allow the
machine to operate with clean water at least twice to rince the solution
from the system.
9. BREAKDOWN ANALYSIS
The TVB100 does not heat up the water. The water remains cold while the
switch for activating the water is on.
9.1 CAUSE AND SOLUTION
- The dry heating protection device is switched off.
The TVB100 is fitted with a dry heating protection device that can
be reached externally at the back (fig. 10A). Remove the protective
cover and press the button. The element will then be switched on again.
- If a breakdown is not caused by the dry heating protection device,
consult your dealer.
TVB10
0
fig. 9
A
fig. 10
A
B
fig. 8