Anhui Yine YN-CA Buck Series User Manual Download Page 14

YN-C Buck series solar charge controller

12

pic 4-3 Display

Table 4-3 Icon function introduction

Table 4-4 Field function introduction

Field

name

Definition

Function Description

Ubattery

Battery

voltage

The field lights up and displays the current battery voltage in
the data display area

Upv

PV panel

voltage

The field lights up and displays the current PV panel voltage in
the data display area

Icharge

Charge

The field lights up and displays the current battery charging

Icon name

definition

Function Description

day

The icon lights up to indicate daylight

night

The icon lights up to indicate the night

Solar panel The icon lights up to check the PV array access

battery

The icon lights up to indicate battery access and the inside

indicates battery voltage

load

The load is lit to indicate that the load has an output

Status icon The icon lights up and scrolls to indicate the chargevstatus

and discharge status,respectively.

Failure icon The icon flashes to indicate that the system has a fault

condition.

Summary of Contents for YN-CA Buck Series

Page 1: ...uck Series Solar Charge Controller User Manual Anhui Yine Technology Co Ltd Dear customer thank you for choosing our products Please read the following instructions carefully before using this product...

Page 2: ...ion instructions 6 3 Wire 7 4 photovoltaic array requirements 9 5 able selection requirements 9 6 Communication port description 9 IV Operate instruction 10 4 1 Indicator function 10 4 2 Setting Butto...

Page 3: ...party and the safety of the equipment In order to avoid personal injury and damage to the equipment all safety warnings and cautions such as the following are strictly observed during operation and ma...

Page 4: ...Do not install the MPPT controller in a location where it may be exposed to lightning strikes Do not install the MPPT controller in a place with a lot of salt spray Good ventilation is required when t...

Page 5: ...rt WIFI module and GPRS module to expand APP cloud monitoring can be applied to communication base stations households Use systems street lighting systems and field monitoring 2 product features Advan...

Page 6: ...n It has comprehensive protection functions such as overcharge over discharge over temperature overload reverse connection and so on 3 product appearance 3 1 product appearance pic 2 1 Product appeara...

Page 7: ...sor External temperature test terminal Measuring battery temperature 8 RS485 Communication port Realize the monitoring of host computer WIFI and GPRS communication III Installation Instruction 1 insta...

Page 8: ...oller and battery in the same confined space Also do not install in a confined space where battery gas may collect 2 installation instructions Step 1 Choose the installation location Avoid installing...

Page 9: ...le load temperature sensor monitoring background Connect the battery load PV module temperature sensor monitoring background host computer WIFI module GPRS module in turn disconnect all switches durin...

Page 10: ...of batteries you need to set the corresponding battery type and series number For details please refer to the relevant settings of the PC host computer or APP manual Caution 1 Danger of electric shoc...

Page 11: ...shows the diameter of the copper wire according to the current level The actual cable size is greater than or equal to the data in the table Table 3 2 cable size 6 Communication port description Photo...

Page 12: ...ght status definition Remar ks 1 Fault indicator red Extinguished Working normally no fault 2 Constantly light on error 3 Charging indicator yellow Light off No charging 4 Light on MPPT charging 5 Slo...

Page 13: ...e key Exit the setup interface button Function 1 display page on page display function 2 parameter setting plus Function 1 Display page under parameter function 2 parameter setting minus UP and DOWN b...

Page 14: ...Charge The field lights up and displays the current battery charging Icon name definition Function Description day The icon lights up to indicate daylight night The icon lights up to indicate the nigh...

Page 15: ...d flashes BCV Boost charge The field lights up to set the battery to raise the charging voltage and during the lifting charging phase the field flashes ECV Equalizd charge The field lights up to set t...

Page 16: ...4 Setup operation 4 4 1 General parameters view Press the Settings set button in standby mode enter the parameter view settings interface and press the SET key to enter the U under R under U over R o...

Page 17: ...interface to exit the setting interface return to the standby interface other conventional parameter settings are similar to the undervoltage setting Figure 4 4 General Parameter Settings Under voltag...

Page 18: ...or DOWN button at this time Set the system ID address 4 4 5 For the setting method of connecting the PC to PC or APP WIFI or GPRS mode please refer to the corresponding PC manual and APP manual respec...

Page 19: ...rotection The controller has its own temperature sensor When the temperature is higher than the set value the charging will stop When the temperature is lowered it will automatically start to work Hig...

Page 20: ...voltage is lower than device startup voltage Heat sink overheatin g Red light on flashes 1 The ambient temperature is too high the heat dissipation of the equipment is poor and the fan is not well ven...

Page 21: ...damage to the controller or even other equipment of the user Note Danger of electric shock When doing this you must ensure that all power to the controller has been disconnected before performing the...

Page 22: ...0 VII Device parameters 1 System parameter table parameter name Parameter value and adjustable range MODEL YN CA YN CB YN CC YN CD Current rating A 10 20 30 40 50 30 40 50 60 70 50 60 80 100 120 Maxim...

Page 23: ...V 24V battery system 40V 80V 24V battery system 80V 145V 48V battery system 160V 240V 48V battery system 160V 240V 96V battery system System identification voltage range V 12V battery sysem DC9V DC16V...

Page 24: ...Charge limit voltage v 10 5 15V 21 30V 49 70V 12 6V Boost charge v 10 5 15V 21 30V 49 70V 12 3V Boost charge return v 10 5 15V 21 30V 49 70V 12V Float voltage v 10 5 15V 21 30V 49 70V 12 3V Over disch...

Page 25: ...YN C Buck series solar charge controller 23 pic 8 1 YN CA Installation diamenion pic 8 2 YN CB Installation dimension...

Page 26: ...YN C Buck series solar charge controller 24 pic 8 3 YN CC Installation diamenion pic 8 4 YN CD Installation diamension...

Page 27: ...probe 1 set optional 4 Monitoring cd software 1 piece optional 5 RJ45 to USB module 1 piece optional 6 1 5m Special network cable 1 piece 7 Host computer communication instructions 1 piece 8 RJ45 to W...