background image

IRONING BOARDS 

 

 

TV/S TV/SG1F TV/SG2F 

 

 

ANGHINETTI & CAMPTEL S.r.l 

Via XX Settembre 95 - 26040 - Gussola (Cr) Italy 

Tel.: +39 0375 / 260885  

  Fax: +39 0375 / 260666  

  e-mail: 

[email protected]

 

Page 

20

 of 

48

 – Rev. 01 

conform  with  current  standards  and  non-
slip floors. 

 

Use adequately sized truck, suitable for the 

load to be handled 

 
 

5.2.2.

 

U

SING THE CRANE OR HOIST

 

 
The  instructions  for  handling  the  machine  using 
crane or hoist, refer to Figure 1. 

 

Figure 1 – Method for lifting machines 

Respect  the  following  instructions  when  loading, 
unloading and moving the machines. 

 

Ropes  or  straps  must  be  securely  hooked  to  the 
machine and to the crane's or hoist's hook. 

 
 

 

The used hooks must have a safety catch 
to avoid rope coming out. 

 

 

 

 

 

All  operators  must  wear  overalls, 
accident-prevention  shoes,  gloves  and 
helmet. 

 

 
 

To move: 

 

 

Use four straps or ropes; 

 

The  ropes/straps  must  be  secured  to  the 

machine's supporting structure; 

 

Ensure  the  ropes,  straps,  hoists  or  cranes 

have  a  higher  capacity  than  that  to  be 
lifted; 

 

Slowly  tension  the  ropes/straps  and  check 

there  are  no  components  involved, 
unsuitable  for  supporting  the  machine's 
weight. 

 

During load handling: 

 

 

Keep away from suspended loads; 

 

Ensure  the  straps  or  ropes  are  securely 

fixed to the structure to be lifted; 

 

Wear 

protective 

gloves, 

accident-

prevention  shoes  with  non-slip  sole, 
overalls and work helmet during operation; 

 

Using  the  acoustic  warning  device,  signal 

the nearing to protected positions and wait 
for operators to reach a safe area. 

 

Check  the  planarity  of  the  units  and  their 
alignment when installing the machine. 
 

 
 
 

 

5.2.3.

 

S

TORAGE

 

Store  the  machine  in  case  of  it's  long  inactivity, 
considering the characteristics of the place 
and  storage  times,  particularly  evaluating  the 
temperature ranges, environmental 
humidity and pollution. 

 

Store the Machine in a closed place 

 

Protect  the  Machine  against  impacts  and 

stresses 

 

Protect  the  Machine  against  humidity  and 

high temperature ranges, +0°C + 60°C 

 

Avoid  the  Machine  coming  into  contact 

with corrosive substances 

Summary of Contents for TV/S

Page 1: ...V SG2F ANGHINETTI CAMPTEL S r l Via XX Settembre 95 26040 Gussola Cr Italy Tel 39 0375 260885 Fax 39 0375 260666 e mail info anghinetti com Page 1 of 48 Rev 01 TV S TV SG1F TV SG2F Instructions manual...

Page 2: ...USED IN MANUAL 7 1 5 TO WHOM THE INSTRUCTIONS MANUAL IS ADDRESSED 8 1 6 INDICATIONS CONTAINED IN THE INSTRUCTIONS MANUAL 8 1 7 PURPOSE OF DOCUMENT 8 1 8 COMPULSORY PRESCRIPTIONS 8 1 9 STANDARD REFERE...

Page 3: ...ICES 15 4 1 STRATEGY FOR CHOOSING SAFETY MEASURE 15 4 2 GENERAL WARNINGS 16 4 3 ADMITTED INTENDED AND NON ADMITTED USES 16 4 4 DANGEROUS AREAS AND RELATIVE SAFETY DEVICES 17 4 4 1 DANGEROUS AREAS 17 4...

Page 4: ...ESSORIES CONNECTIONS 22 6 USE INSTRUCTIONS 23 6 1 INTRODUCTION 23 6 2 OPERATION ADJUSTMENT AND SWITCH ON 23 6 3 USE 24 6 4 SWITCH OFF PLACING OUT OF SERVICE STOP 24 7 MAINTENANCE 25 7 1 ESSENTIAL STAN...

Page 5: ...INDICATIONS BASED ON MACHINE MODEL AND FEATURES INDICATED ON PLATE ATTACHMENT 4 TV SG1F 2F WIRING DIAGRAMS FOR V 230 AC 1PH 50 60 HZ power supply ATTACHMENT 5 TV SG1F 2F WIRING DIAGRAMS FOR V 230 AC 3...

Page 6: ...amaged Manual from the Manufacturing company The Manual must be kept near the machine in a safe place known to all personnel in charge and accessible only to the same Treat the Manual carefully it is...

Page 7: ...LSORY THE USE OF PROTECTIVE GOGGLES IS COMPULSORY THE USE OF EAR PROTECTION IS COMPULSORY THE USE OF PROTECTIVE VISOR IS COMPULSORY OVERALLS MUST BE WORN DANGER SIGN PAY THE UTMOST ATTENTION ELECTROCU...

Page 8: ...of machine installation place Installation and connections Operation safety systems workstations Description function adjustment and maintenance of machine units Machine use Maintenance Spare parts or...

Page 9: ...logical Know how created from years of research in tight contact with national and international production and marketing that represents the best guarantee ANGHINETTI CAMPTEL S r l owner of the CAMPT...

Page 10: ...ANCE AND MAINTENANCE Check any malfunctioning does not fall within the operations described for scheduled maintenance refer to paragraph 7 5 on the contrary contact the Manufacturing company s After S...

Page 11: ...operators their qualifications and intervention procedures must be optimal Using a higher or lower number of operators than indicated with different or inadequate qualifications or adopting different...

Page 12: ...Qualified technician able to run the machine in normal conditions in manual cycle jog perform all electrical interventions for adjustment maintenance and repair Enabled to work with electric voltage p...

Page 13: ...arantee sufficient protection against accidents their removal or tampering entails high probability of risks for the exposed persons health and safety The removal or tampering of the Safety Devices li...

Page 14: ...nt type of clothing Its improper use is not covered by the Manufacturing Company s liability Refer to the manufacturing drawings for the standard and optional supplied mechanical structures attachment...

Page 15: ...o reduce possibility of its incorrect use leading to a dangerous condition Has identified the dangerous areas and adopted suitable protective systems Has designed and realised Safety Devices and guard...

Page 16: ...Prevent untrained persons from nearing the machine The user is responsible for installing a Protective Device against overcurrents for the electric equipment s power supply conductors paragraph 5 3 2...

Page 17: ...tion of its manufactured systems or machines It is strictly forbidden for operators to climb onto the machine It is strictly forbidden for operators to rest or intervene on the machine unless it is in...

Page 18: ...sounds N B more or less buttons may be present depending on model FIGURE 5 4 4 3 SAFETY CASINGS The machine has 4 safety casings fitted onto the frame so that the dangerous parts are not directly acce...

Page 19: ...s reduced sizes it does not necessarily require disassembly for its handling using adequately sized forklift truck or specific crane or hoist Professionally qualified Personnel must perform Transport...

Page 20: ...e the ropes straps hoists or cranes have a higher capacity than that to be lifted Slowly tension the ropes straps and check there are no components involved unsuitable for supporting the machine s wei...

Page 21: ...AND VERIFICATIONS Preparation for Machine commissioning does not require particular knowledge apart from those obtainable from consulting this manual Carry out some verifications and checks before st...

Page 22: ...ed according to machine type and power N B always refer to the technical data plate to identify correct voltage See figure 8 for power supply cable position FIGURE 8 A Power supply cable B 1 2 Boiler...

Page 23: ...accidents due to negligence and non compliance with the above The Machine was conceived for use by one Operator only Personnel in charge of working on the Machine must have or acquire through adequat...

Page 24: ...itches off allowing use of steam A control unit controls water level in boiler circuit allowing its automatic reset Indicator Ref 1 fig 9 shows boiler heating elements operation on active heating elem...

Page 25: ...on see paragraph 6 4 before any maintenance operation and signal that particular tasks are being carried out by exhibiting the MACHINE UNDER MAINTENANCE sign It is strictly forbidden for the machine t...

Page 26: ...e machine s safety systems micro switches Emergency Stop buttons etc 7 4 BOILER CLEANING The Anghinetti ironing boards are designed and manufactured for best operation and less maintenance possible We...

Page 27: ...the machine s individual units correct operation before starting production 7 7 SCHEDULED MAINTENANCE The following operations must be carried out when indicated Lack in respecting that requested exem...

Page 28: ...dentify the component and its code by using the ATTACHMENTS at the end of this manual 9 DISMANTLING The following paragraph gives advise and suggestions for dismantling the equipment 9 1 DISPOSAL Wast...

Page 29: ...DS TV S TV SG1F TV SG2F ANGHINETTI CAMPTEL S r l Via XX Settembre 95 26040 Gussola Cr Italy Tel 39 0375 260885 Fax 39 0375 260666 e mail info anghinetti com Page 29 of 48 Rev 01 ATTACHMENT 1 TV S TV S...

Page 30: ...RONING BOARDS TV S TV SG1F TV SG2F ANGHINETTI CAMPTEL S r l Via XX Settembre 95 26040 Gussola Cr Italy Tel 39 0375 260885 Fax 39 0375 260666 e mail info anghinetti com Page 30 of 48 Rev 01 ATTACHMENT...

Page 31: ...cal power supply has the same features as those on the technical data plate Respect the technical standards and laws in the place and at time of installation install the following devices or others wi...

Page 32: ...installation install the following devices or others with equal features Electric energy must have the following requirements according to machine model DESCRIPTION DATA IDM Circuit breaker different...

Page 33: ...s or others with equal features Electric energy must have the following requirements according to machine model DESCRIPTION DATA IDM Circuit breaker differential switch 4P Brand ABB For 3 5 kw boiler...

Page 34: ...es or others with equal features Electric energy must have the following requirements according to machine model DESCRIPTION DATA IDM Circuit breaker differential switch 4P Brand ABB For 3 5 kw boiler...

Page 35: ...of installation install the following devices or others with equal features Electric energy must have the following requirements according to machine model DESCRIPTION DATA IDM Circuit breaker differ...

Page 36: ...s or others with equal features Electric energy must have the following requirements according to machine model DESCRIPTION DATA IDM Circuit breaker differential switch 4P Brand ABB For 3 5 or 5 kw bo...

Page 37: ...s or others with equal features Electric energy must have the following requirements according to machine model DESCRIPTION DATA IDM Circuit breaker differential switch 4P Brand ABB For 3 5 or 5 kw bo...

Page 38: ...RONING BOARDS TV S TV SG1F TV SG2F ANGHINETTI CAMPTEL S r l Via XX Settembre 95 26040 Gussola Cr Italy Tel 39 0375 260885 Fax 39 0375 260666 e mail info anghinetti com Page 38 of 48 Rev 01 ATTACHMENT...

Page 39: ...RONING BOARDS TV S TV SG1F TV SG2F ANGHINETTI CAMPTEL S r l Via XX Settembre 95 26040 Gussola Cr Italy Tel 39 0375 260885 Fax 39 0375 260666 e mail info anghinetti com Page 39 of 48 Rev 01 ATTACHMENT...

Page 40: ...RONING BOARDS TV S TV SG1F TV SG2F ANGHINETTI CAMPTEL S r l Via XX Settembre 95 26040 Gussola Cr Italy Tel 39 0375 260885 Fax 39 0375 260666 e mail info anghinetti com Page 40 of 48 Rev 01 ATTACHMENT...

Page 41: ...RONING BOARDS TV S TV SG1F TV SG2F ANGHINETTI CAMPTEL S r l Via XX Settembre 95 26040 Gussola Cr Italy Tel 39 0375 260885 Fax 39 0375 260666 e mail info anghinetti com Page 41 of 48 Rev 01 ATTACHMENT...

Page 42: ...RONING BOARDS TV S TV SG1F TV SG2F ANGHINETTI CAMPTEL S r l Via XX Settembre 95 26040 Gussola Cr Italy Tel 39 0375 260885 Fax 39 0375 260666 e mail info anghinetti com Page 42 of 48 Rev 01 ATTACHMENT...

Page 43: ...0 2 70 031A BRACKET D 8 art 1015 1009052 3 50 413A MICRO BUTTON PIZ MS05 4 50 413B CASING PIZ C 02 X MICRO 7 50 290 A BLACK RED TWO POLE SWITCH 825082771E 8 105 020A RUBBER FOOT FOR BASE 9 50 256A SEL...

Page 44: ...01 ATTACHMENT 10 POS CODE DESCRIPTION 1 165 008 B CYL HOSE HOLDER M 3 8 X 12 2 250 028 A ELBOW MF 3 135 020 M WATER PUMP PQM60 V 230 50HZ 4 250 078 A CYL MF REDUC 449 1 3 8 5 55 362 A WATER SOLENOID V...

Page 45: ...10 B 400 8 55 148 B FREE DRAIN SAFETY VALVE 1 2 9 20 018 A 245 490 B RECT BOILER PRISMATIC BOILER INSULATOR 10 90 128 A HEATING ELEMENT W 5000 V 230 400 FLANGE D 110 S G 10 90 120 A HEATING ELEMENT W...

Page 46: ...ndicate voltage on the plate when ordering POS CODE DESCRIPTION 1 50 067 A SINGLE BLOCK LAMP WITH 2 50 290 A BLACK RED TWO POLE SWITCH 825082771E 3 50 342 A 50 342 B STRAIGHT CASING CK 03 V PLUG BODY...

Page 47: ...e Ironing board Model TV S TV SG1F TV SG2F is conform with the following Directives Machinery Directive 2006 42 EC Electromagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC...

Page 48: ...IRONING BOARDS TV S TV SG1F TV SG2F ANGHINETTI CAMPTEL S r l Via XX Settembre 95 26040 Gussola Cr Italy Tel 39 0375 260885 Fax 39 0375 260666 e mail info anghinetti com Page 48 of 48 Rev 01...

Reviews: