background image

 
WARNING: SAFETY AND ELECTRICAL CONNECTIONS

 

The pump is supplied with 5m of 3 core electrical cable which is permanently connected and 

sealed to the motor. The supply cable cannot be replaced. If the cable is damaged the pump 

should be discarded. 

1. 

Pump 

U

must be connected to an approved ground fault circuit interrupter

U

 (GFCI) 

receptacle.

 

2. 

Do not connect to any voltage other than that stated on the pump.

 

3. 

  Warning: 

U

Always

U

 unplug or disconnect all appliances from the electrical supply 

before putting hands in the water, while equipment is being installed, repaired, 

maintained or handled.

 

4. 

  Do not use the supply cable to lift the pump as this may cause damage.

 

5. 

  Do not operate or leave the pump in freezing conditions.

 

6. 

  Do not allow the pump to run dry. The pump must be fully submerged.

 

 

INSTALLATION IN POND 

Place your pump on top of a flat brick or stone approximately 2” – 4” from the bottom of 

your pond to help prevent debris from interfering with the pump’s performance.

 

Make sure the cable is securely routed to the GFCI electrical supply and is protected 

against abrasion and damage.

 

After  electrical  installation  to  test,  completely  submerge  the  pump  under  water.  When  your 

pump is working properly, you will hear a low humming sound and water will be circulating out 

of the top outlet. If  you do not hear the humming sound or experience performance problems, 

please read the troubleshooting tips and care instructions in this guide.

 

 

 
 
 
 
 
 
 

 
TECHNICAL SPECIFICATIONS

 

Model

 

Liters/ 

Hr

 

 

Voltage

 

 

Watts

 

Max 

Head 

cm

 

AD40402 

1600 

120 

35 

260 

 
HINTS AND TROUBLESHOOTING 

CAUTION: 

U

ALWAYS

U

 DISCONNECT THE PUMP FROM THE ELECTRICAL 

SUPPLY BEFORE HANDLING

If the pump operates but there is no water flow:

 

 

Make sure the pump is fully submerged.

 

 

Check the tubing for kinks or obstructions. Ensure pump outlet is clear of objects.

 

 

Check water features like spouting statues or fountain nozzles are clean and clear.

 

 

Check water inlet for any obstructions.

 

If normal water flow has not returned: 

 

Remove front cover and impeller cover to access rotor area.

 

 

Rotate the rotor to ensure it is not broken or jammed. Remove the rotor 

to check it is free from any debris. Rinse the cover and re-assemble. 

 
MAINTENANCE 

 

Regular maintenance must be performed on any warranted item based upon this Owner’s 

Guide recommendations. Do not pump heated liquids, and always keep the cord away from 

heat and high temperature. Connect the pump to an electrical supply with the proper voltage 

and fitted with a Residual Current Device. 

1. Always disconnect the pump from the electrical supply before handling it.

 

2. Pond water must be kept clean using proper filtration components.

 

3. Always operate the pump completely submerged. Check the water level daily to 

ensure the pump will remain submerged. Add water if necessary.

 

4. Clean the pump periodically to prevent mineral deposits and contamination. 

5. Disassemble the unit to clean any build up of debris inside the impeller and rotor.

 

6. Do not operate this pump below 0°C, otherwise 

U

Freezing damage May Occur

U

. If 

temperature is likely to fall below 0°C remove the pump from the pond, ensure all water is 

removed from the pump and the unit is completely dry and stored in a frost-free place. 