INSTALLATION
L20-352-UK Rev.1 08/12
3
a.
Fill the tank with water. Turn the appliance on and set the thermostat to 200°F (93°C) Refer to
the APPLIANCE START UP section of this manual for instructions.
b.
Allow the appliance to heat for 15 minutes. Add Anets cleaner to the water, stirring with the
cleaning brush to ensure that the cleaner dissolves thoroughly.
CAUTION
DO NOT leave the appliance unattended during cleaning. Never let the water level go below the
“Oil Level” mark stamped on the tank.
c.
Using the cleaning brush, scrub the inside of the tank to remove the protective coating.
d.
When cleaning is complete turn the appliance off and drain the water into a container suitable
for hot water and dispose of it.
WARNING
Wear protective gloves and clothing when cleaning and draining the appliance and when
disposing of water. The water is extremely hot and can cause severe injuries.
e.
When the tank has cooled, rinse thoroughly with cool water. Continue to rinse the tank
until the cleaner has been completely and thoroughly rinsed from the tank.
f.
Using a clean dry cloth, wipe out all of the water. Be very thorough when removing the
water, as any residual water will cause hot shortening/oil to splatter out of the appliance.
FILLING THE TANK WITH SHORTENING OR OIL
Both liquid and solid shortening/oil can be used in this appliance, but liquid is preferred. If solid shortening/oil is
used it is recommended that you melt the shortening/oil before adding it to the appliance. You can melt solid
shortening/oil in the appliance, but you must be very careful not to scorch the shortening/oil.
Filling the tank with liquid shortening/oil
To fill the tank with liquid shortening/oil refer to the following procedure:
a.
Ensure that the drain valve is completely closed and that there is no residual moisture in the tank.
b.
Fill the tank with shortening/oil. You may fill the tank to the “OIL LEVEL” mark or slightly below
the nominal level mark: the shortening/oil will expand slightly when it heats up, raising the level
slightly.
Filling the tank with solid shortening/oil
To fill the tank with solid shortening/oil, refer to the following procedure:
WARNING
NEVER melt blocks of solid shortening/oil on top of the burner tubes. This will cause a fire
and could result in personal injury.
a.
Ensure that drain valve is completely closed and that there is no residual moisture in tank.
Remove the basket screen.
b.
Cut the solid shortening/oil into cubes no larger than one inch. ALWAYS pack the shortening/oil
below, between, and on top of the burner tubes.
DO NOT
leave any large air gaps. Use care
when packing the solid shortening/oil into the tank.
DO NOT
bend or break the temperature or
high limit sensor probes. If these are damaged the appliance will not function properly.