1
INSTRUCTION MANUAL
HVLP Spray Gun
Be sure to observe warning s and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following marked items which are especially important
.
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury
or property damage.
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are
the minimum necessary conditions. Follow national and local regulations regarding fire prevention,
electricity and safety as well as your own company regulations.
Symbol Marking on the Spray Gun:
II 2 G Ex h X
This ANEST IWATA spray gun complies
with 2014/34/EU Directive relating to
equipment and protective systems
intended for use in explosive potentially
atmospheres.
II
2
G
Ex h
IIB
T6
Gb
X
T
Amb
+5°C +40°C
Complies
with
European
Directive
Specific
Marking for
Explosion
Protective
Group II
(Surface)
Category
(Zone 1&2)
Type of
Atmosphere
(GAS)
Ignition
Protection
(not applied)
Explosion
Group
(Ethylene)
Temperature
Class
( 85°C)
Explosion
Protection
level
(EPL)
Additional
conditions:
Any static
Electricity should
be discharged
and needs to be
diverted to the
ground via a
conductive air
hose not
included.
Ambient
Temperature
Important specifications
Max. Pressure
0.70MPa / 7.0bar / 100psi
Noise level
80dB(A)
Spray condition
Recommended
Measuring point
1m backwards from spray gun, 1.6m height
Max. temperature
Atmosphere: 5°C ~40°C (41°F~104°F)
Air and Fluid: 5°C ~43°C (41°F~109°F)
*1. Atomizing air pressure means air pressure at spray gun inlet when trigger is pulled and air flows.
Main specifications
Model
Type of
feed
Fluid nozzle
Air cap assy Mark
Recommended condition
Air consumption
l/min (cfm)
Pattern width
mm (in)
Air & fluid
connection
Mass
g (lbs.)
Nozzle orifice
mm (in)
Mark
*1 Atomizing air
pressure
MPa (bar / PSI)
Air pressure
inside air cap
MPa (bar / PSI)
Fluid output
ml/min
WIDER2L-10G2P
Pressure
1.0 (0.039)
W2L
WIDER2L-G2
0.20
(2.0 / 28)
0.07
(0.7 / 10)
300
470 (16.6)
250 ( 9.8)
Air
G1/4
(NPS1/4)
Fluid
G3/8
(NPS3/8)
375
(0.83)
-12G2P
1.2 (0.047)
500
300 (11.8)
-14G2P
1.4 (0.055)
500
300 (11.8)
WIDER2L-2-10G2P
1.0 (0.039)
W2L-2
WIDER2L-2-G2
100
430 (15.2)
330 (13.0)
-12G2P
1.2 (0.047)
130
350 (13.8)
This manual contains IMPORTANT
WARNINGS and INSTRUCTIONS.
Equipment in this manual is exclusively for
painting purposes.
Do not use for other purposes.
The operator shall be fully conversant with the
requirements stated in this instruction manual
including important warnings, cautions and
operation and correct handling.
Read and understand the instruction manual,
before use and retain for reference.
Fluid nozzle – Fluid needle assy combination
Model
Fluid nozzle
Fluid needle
assy
Orifice mm (in)
Mark
Mark
WIDER2L-10G2P
1.0 (0.039)
/ W2L / 10
12H WIDER2
WIDER2L-12G2P
1.2 (0.047)
/ W2L / 12
WIDER2L-14G2P
1.4 (0.055)
/ W2L / 14
15H WIDER2
WIDER2L-2-10G2P
1.0 (0.039)
/ W2L-2 / V8-10
12H WIDER2
WIDER2L-2-12G2P
1.2 (0.047)
/ W2L-2 / V8-12
IMPORTANT WARNING: Our spray guns, airbrushes, and other products are made to conform by our local group companies with local laws and regulations
that may differ from place to place. Improper trade of products outside of designated domestic territories (unauthorized reselling) can result in legal violations,
local fines, and penalties. ANEST IWATA CORPORATION assumes no liability for products acquired through unauthorized reselling and in such cases and due
to quality control protocols, unauthorized reselling renders the warranty null and void.