Anest Iwata WIDER2-12G2P Instruction Manual Download Page 3

− 

3

  − 

How to connect

Use clean air filtered through air dryer and air filter.

If not, dirty air can cause painting failure.

If you use this spray gun for the first time after purchasing, clean fluid passages spraying thinner and remove rust preventive oil. 

If not, remaining rust preventive oil can cause painting failure such as fish eyes.

Firmly fix hose or container to spray gun.

  If not, disconnection of hose and drop of container can cause bodily injury

Job1. Connect an air hose to air nipple tightly.
Job2. Connect a fluid hose or a container to fluid nipple tightly.
Job3. Flush the spray gun fluid passage with a compatible solvent.
Job4. Pour paint into container, test spray and adjust fluid output as well as pattern width.

■ 

Maintenance and inspection

First release air and pressure fully according to item No. 3 of “Improper use of equipment” of WARNING on page 2. 

Only an experienced person who is fully conversant with the equipment can do maintenance and inspection. 

Use neutral cleaner:pH value shall be 6 to 8, otherwise could cause corrosion.

Never use commercial or otherparts instead of ANEST IWATA original spare parts.

Step-by-step procedure

1. Pour remaining paint to another container.    Clean fluid passages andair cap assy.

Spray a small amount of thinner to clean fluid passages. 

1. Incomplete cleaning can fail pattern shape and uniform particles.

Especially clean fully and promptly two-component paint after use. 

2. Clean each section with brush soaked with thinner and wipe out with waste cloth.

2. Soaking whole spray gun in solvent may cause spray gun malfunction. Also soaking air 

cap assy itself for extended period may cause defective pattern. 
When cleaning, never scratch each hole of air cap assy, fluid nozzle, and fluid needle 
assy. 
Never damage the tip of fluid nozzle or must not put your hand on it. 

3. Before disassembly, fully clean fluid passages. 

Remove fluid nozzle, using a ring spanner, box wrench or optional accessory spanner 

(code 93538601)

3. During disassembly, do not scratch seat section. 

Either first remove the fluid needle or hold the trigger back while removing the fluid nozzle, 

to protect the seating surface. 

4. When you want to adjust fluid needle packing set, first tighten it by hand while fluid needle 

assy remains inserted. Then tighten it further about 1/6 turn (60-degree) by spanner.   
When you remove needle packing set, do not leave plastic piece of needle packing set in 
the spray gun body. 

4. If you tighten fluid needle packing set too much, fluid needle assy will not move smoothly, 

resulting in paint leakage from tip of fluid nozzle. Try to adjust it carefully while pulling 
trigger and confirming movement of fluid needle assy. 

When you tighten it too much, first fully loosen it and then tighten it again carefully. 

5. To assemble the air valve, first assemble the air valve, air valve spring, and fluid adj. guide 

assy. together. Next, insert fluid needle into fluid adj. guide assy., then fit it to spray gun 
body and screw fluid adj. guide assy. in 

5. If you try to fit air valve spring and air valve to spray gun body set without fluid needle 

assy, air valve will not be fitted correctly and lop packing inside fluid adj. guide assy will 

be damaged. 

6. Before assembling the pattern adj. assy. or air adj. assy. back on to the gun body, fully turn 

the adjustment knobs counterclockwise to open. Once in the gun body the pattern adj. 
knob and air adj. knob can be tightened. 

6. If pattern adj. knob or air adj. knob is not fully opened when tightening into gun body, the tip 

of it can contact and damage the seating surface. 

7. When you assemble the needle spring on the fluid needle, the plastic tip should be on the 

opposite side as the fluid needle tip. 

7. If plastic tip is on the wrong side, it may not operate normally. Incorrect installation of the 

needle spring may cause a heavy trigger pull. 

Where to inspect

Parts replacement standard

1. Each hole passage of air cap assy and fluid nozzle

Replace if it is crushed or deformed.

2. Packing and O ring

Replace if it is deformed or worn out.

3. Leakage from seat section between fluid nozzle and fluid needle assy

Replace them if leakage does not stop after fully cleaning the fluid nozzle and needle. 
If you replace the fluid nozzle or fluid needle only, ensure they fully match and confirm that 
there is no leakage. 

Fluid (Gravity) 

Fluid nipple 

Fluid

(Suction / Pressure) 

Air 

Air nipple

Fluid needle

Needle spring assy

Plastic tip