Anest Iwata SER-24PA Instruction Manual Download Page 2

■ 

List of residual risks

*1. "Degree of danger" is classified and described according to the definition below.

DANGER

Indicates that a person is likely to die or be seriously injured if protective measures are not implemented.

WARNING

Indicates that if the warning is neglected, it may result in death or serious injury.

CAUTION

Indicates that if the caution is neglected, it may result in injury or property damage.

*2. The symbols shown as "locations on equipment" are corresponding to each location listed in the "Residual Risk Map" of this product. Refer to the "Residual Risk 
Map" for specific parts on the product.

No

Operation

Stage

Work

Required 

qualification 

/education   

for the work

Location 

on the 

product

*2

Degree of 
danger *1

Contents of Degree

Protective measures 
implemented by users

1

Use

During work

C

Warning

Tenosynovitis due to repeated triggering 
movements.

Take an adequate rest

2

Use and 
maintenance

In preparation 
work, 
During work

Not 

specified

Warning

Unexpected breakdowns or accidents occur when 
the product is modified or parts other than 
genuine parts are used.

Do not modify
Use of genuine parts

3

Use

In preparation 
work, 
During work

Not 

specified

Warning

Hearing loss due to long stay in a noisy place

Recommended to use of 
earplugs

4

Use and 
maintenance

In preparation 
work, 
During work

A

Warning

While pressurized, if tried to disconnect the hose, 
air will blow out and it may result in injury.

Wear protective equipment
Remove residual pressure

5

Use

In preparation 
work, 
During work

B

Warning

There is a risk of electric shock.

Periodic inspection

6

Use

During work

Not 

specified

Warning

Injury due to removed dust getting into eyes or 
inhaled

Wear protective equipment

■ 

Safety Precautions

Be sure to follow the warnings and precautions described in this instruction manual. Unconsidered air blowout or electric shock during use may cause serious physical 
damage.
Be  sure  to  observe  the  following  symbols  marked  with  this 

symbol, which are particularly important for safety. The safety items shown in this instruction 

manual are the minimum necessary.
Follow the laws and regulations related to firefighting, electricity, and safety of the national and local governments, as well as the rules and regulations of each 
company and place of business.

  WARNING

Indicates that if the warning is neglected, it may result in death or serious injury.

  CAUTION

Indicates that if the caution is neglected, it may result in injury or property damage.

WARNING

This product is non-explosion proof. Do not install or use the product in an atmosphere or place where flammable gases or solvents are handled. 

Otherwise, ignition or explosion may result.

This product generates ozone. Do not use it in an enclosed space.

Otherwise, the ozone concentration in the enclosed space may increase, resulting in the development of chronological bronchitis, etc.

 A high voltage is applied to the electrode needle. Do not put any conductive objects such as fingers, body, wires and tools closer to

the electrode needle. Failure to do so may cause an electric shock or malfunction.

The electrode needle has a pointed tip. Handle it with care. Failure to follow may result in bodily injury.

■ 

Cautions

This product is designed and manufactured as parts for use in general industrial machinery.
Do not use this product for any purpose other than neutralization (neutralizing static electricity).
Do not install the product in a closed place, but install it in a well-ventilated place.
Do not disassemble or modify the product.
Do not remove the bush inside the nozzle before use. The static elimination (neutralization) effect is reduced.
Be sure not to put any foreign matter inside this product. Failure to avoid may cause a short circuit or electric leakage, resulting in a fire or electric shock.
If there is an abnormal noise or odor, smoke or heat, immediately turn off the power, unplug the power cable, and contact the distributor or the place of purchase. 

If it is continuously used, there is a risk of fire or electric leakage.

Do not splash water on this product. Splashing water, washing, or using the product underwater may cause an injury, electric shock, or fire due to abnormal operation.
Do not touch the electrode needle directly.
If the power is turned on immediately after turning off the power of the product, an anomalous output occurs. When turning ON after turning OFF, provide the time 

interval of 1 second or longer.

Do not wire in parallel with power lines or high-voltage lines or use the same piping. There is a risk of malfunction due to induction noise.
Do not use the attached cable for moving parts as it may break.
Do not damage the attached cable. If the cable is damaged, forcibly bent, pulled, wound, placed under a heavy object, or pinched, it may cause a fire, electric shock, 

or abnormal operation due to electric leakage or conduction failure.

Do not connect or disconnect the connector while the power is on. Also, do not apply unnecessary stress to the connector. It may cause injury, damage to the device, 

electric shock, and etc. due to malfunction of the device.

If the product will not be used for a long period of time, turn off the power for safety.

■ 

Overview

This product is an air gun type electrostatic eliminator. It can be used freely by holding it in hand.
The gun is equipped with a high-voltage power supply and an air valve, which does not require any external controller.
Equipped with the wave motion air nozzle, it can strongly remove dust by blowing shock waves.
Ionized air is blown onto the electric-charged body to quickly and effectively neutralize the static electricity of the charged body and prevent the reattachment of dust

  due to static electricity.

Summary of Contents for SER-24PA

Page 1: ...r be seriously injured if protective measures are not implemented WARNING Indicates that if the warning is neglected it may result in death or serious injury CAUTION Indicates that if the caution is n...

Page 2: ...ozone concentration in the enclosed space may increase resulting in the development of chronological bronchitis etc A high voltage is applied to the electrode needle Do not put any conductive objects...

Page 3: ...15 65 unless no condensation Indicators Green Power supply normal Red Decrease in output power Ozone generation 0 04 ppm or less 200 mm from the spout air pressure 0 3MPa Ion balance Within 30V Materi...

Page 4: ...unit or the nozzles will become dirty lowering the electrostatic elimination performance and causing deterioration of the main unit Secure a work space when installing this product Also secure enough...

Page 5: ...fficient the nozzle may loosen due to the vibration of the wave motion air nozzle which is dangerous if it comes off Connect the power input cable of the main unit gun to the AC adapter Connect the AC...

Page 6: ...htening torque to 1 5 to 2 0N cm If the torque is not correct the thread of the gun body side may be damaged Operation 1 Open the main valve of the air equipment installed by the customer and supply a...

Page 7: ...tightening torque for replacement to 1 5 to 2 0N cm If the torque is not correct the screws of the main unit may be damaged How to replace the electrode needle The electrode needle a consumable part a...

Page 8: ...8 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan No T1090 00...

Reviews: