2
■
List of residual risks
*1. "Degree of danger" is classified and described according to the definition below.
DANGER
Indicates that a person is likely to die or be seriously injured if protective measures are not implemented.
WARNING
Indicates that if the warning is neglected, it may result in death or serious injury.
CAUTION
Indicates that if the caution is neglected, it may result in injury or property damage.
*2. The symbols shown as "locations on equipment" are corresponding to each location listed in the "Residual Risk Map" of this product. Refer to the "Residual Risk
Map" for specific parts on the product.
No
Operation
Stage
Work
Required
qualification
/education
for the work
Location
on the
product
*2
Degree of
danger *1
Contents of Degree
Protective measures
implemented by users
1
Use
During work
C
Warning
Tenosynovitis due to repeated triggering
movements.
Take an adequate rest
2
Use and
maintenance
In preparation
work,
During work
Not
specified
Warning
Unexpected breakdowns or accidents occur when
the product is modified or parts other than
genuine parts are used.
Do not modify
Use of genuine parts
3
Use
In preparation
work,
During work
Not
specified
Warning
Hearing loss due to long stay in a noisy place
Recommended to use of
earplugs
4
Use and
maintenance
In preparation
work,
During work
A
Warning
While pressurized, if tried to disconnect the hose,
air will blow out and it may result in injury.
Wear protective equipment
Remove residual pressure
5
Use
In preparation
work,
During work
B
Warning
There is a risk of electric shock.
Periodic inspection
6
Use
During work
Not
specified
Warning
Injury due to removed dust getting into eyes or
inhaled
Wear protective equipment
■
Safety Precautions
Be sure to follow the warnings and precautions described in this instruction manual. Unconsidered air blowout or electric shock during use may cause serious physical
damage.
Be sure to observe the following symbols marked with this
symbol, which are particularly important for safety. The safety items shown in this instruction
manual are the minimum necessary.
Follow the laws and regulations related to firefighting, electricity, and safety of the national and local governments, as well as the rules and regulations of each
company and place of business.
WARNING
Indicates that if the warning is neglected, it may result in death or serious injury.
CAUTION
Indicates that if the caution is neglected, it may result in injury or property damage.
WARNING
This product is non-explosion proof. Do not install or use the product in an atmosphere or place where flammable gases or solvents are handled.
Otherwise, ignition or explosion may result.
This product generates ozone. Do not use it in an enclosed space.
Otherwise, the ozone concentration in the enclosed space may increase, resulting in the development of chronological bronchitis, etc.
A high voltage is applied to the electrode needle. Do not put any conductive objects such as fingers, body, wires and tools closer to
the electrode needle. Failure to do so may cause an electric shock or malfunction.
The electrode needle has a pointed tip. Handle it with care. Failure to follow may result in bodily injury.
■
Cautions
This product is designed and manufactured as parts for use in general industrial machinery.
Do not use this product for any purpose other than neutralization (neutralizing static electricity).
Do not install the product in a closed place, but install it in a well-ventilated place.
Do not disassemble or modify the product.
Do not remove the bush inside the nozzle before use. The static elimination (neutralization) effect is reduced.
Be sure not to put any foreign matter inside this product. Failure to avoid may cause a short circuit or electric leakage, resulting in a fire or electric shock.
If there is an abnormal noise or odor, smoke or heat, immediately turn off the power, unplug the power cable, and contact the distributor or the place of purchase.
If it is continuously used, there is a risk of fire or electric leakage.
Do not splash water on this product. Splashing water, washing, or using the product underwater may cause an injury, electric shock, or fire due to abnormal operation.
Do not touch the electrode needle directly.
If the power is turned on immediately after turning off the power of the product, an anomalous output occurs. When turning ON after turning OFF, provide the time
interval of 1 second or longer.
Do not wire in parallel with power lines or high-voltage lines or use the same piping. There is a risk of malfunction due to induction noise.
Do not use the attached cable for moving parts as it may break.
Do not damage the attached cable. If the cable is damaged, forcibly bent, pulled, wound, placed under a heavy object, or pinched, it may cause a fire, electric shock,
or abnormal operation due to electric leakage or conduction failure.
Do not connect or disconnect the connector while the power is on. Also, do not apply unnecessary stress to the connector. It may cause injury, damage to the device,
electric shock, and etc. due to malfunction of the device.
If the product will not be used for a long period of time, turn off the power for safety.
■
Overview
This product is an air gun type electrostatic eliminator. It can be used freely by holding it in hand.
The gun is equipped with a high-voltage power supply and an air valve, which does not require any external controller.
Equipped with the wave motion air nozzle, it can strongly remove dust by blowing shock waves.
Ionized air is blown onto the electric-charged body to quickly and effectively neutralize the static electricity of the charged body and prevent the reattachment of dust
due to static electricity.