-8-
Multi-spray gun
Important
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following
marked items which are especially important.
Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or
property damage.
Important
Indicates notes which we ask you to observe. The safety precautions in this instruction manual are the
minimum necessary conditions. Follow national and local regulations regarding fire prevention, electricity and
safety as well as your own company regulations.
■
Important specifications
Max. Pressure
Fluid
;
9.8MPa / 98bar / 1440PSI
Max. Temperature
Air
;
0.68MPa / 6.8bar / 98PSI
Atmosphere
5
℃~
40
℃
Noise level
69 dB(A)
Air
・
Fluid
5
℃~
43
℃
Spray condition
Used
Nozzle
tip
; NT2004CMU
Atomizing air pressure ; 0.15MPa / 1.5bar / 21.4PSI
※
Fluid pressure ; 10MPa / 100bar / 1440PSI
Tested with water
Measuring point
1m backwards from gun, 1.6 m height
※
Atomizing air pressure means air pressure at gun inlet when trigger is pulled and air flows
.
■
Main specifications
Model
Use
Max.operating fluid
pressure
MPa
(bar / PSI)
Operating fluid
pressure
MPa
(bar / PSI)
Max.atomizing air
pressure
MPa
(bar / PSI)
Operating atomizing
air pressure
MPa
(bar / PSI)
Filter
Size
(mesh)
Air & fluid
connection
Mass
g
(lbs)
MSG-200 General
9.8
(98 / 1440)
4.9
(49 / 720)
0.68
(6.8 / 98)
0.15
(1.5 / 21.4)
#200
G 1/4
480 (1.06)
※
Fluid output ; See 4.Selection of nozzle tip according to kind of paint.
This Anest-iwata multi- spray gun kit complies to
ATEX regulations 94/9/EC,
Protection level
:
Ⅱ
2 G X
,
Suitable for use in Zones 1 and 2.
X marking
:
Any static electricity discharge from the multi-
spray gun is to be diverted to the grounded
the conductive fluid hose as stipulated.
MSG-200
INSTRUCTION MANUAL
This manual contains IMPORTANT WARNINGS and INSTRUCTIONS.
Equipment in this manual is exclusively for painting purposes.
Do not use for other purposes.
The operator shall be fully conversant with the requirements stated in this
instruction manual including important warnings, cautions and operation and
correct handling.
Read and understand the instruction manual, before use and retain for
reference.
WARNING
CAUTION
Summary of Contents for MSG-200
Page 1: ...kgf cm2 kgf cm2 kgf cm2 a kgf cm2...
Page 2: ...mm...
Page 3: ......
Page 4: ......
Page 5: ...20 3 20 2 min cm min cm cm cm MPa kgf cm2 kgf cm2 cm ml sec cm...
Page 6: ...This warranty is valid only in Japan 9 00 12 00 13 00 17 00 http www anest iwata co jp...
Page 16: ...16 Manual No 1231 07 Code No 03522224 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan...