-16-
Terminal plate (2pcs)
Terminal Block
Electric Source
Terminal M4 Nut
Ground Terminal
M5 Bolt
200V Connection
(When delivered to you)
100V Connection
How to wire
①
Remove 4pcs. of M5 bolt at motor terminal box and remove protection cover.
※
Be careful not to lose removed M5 bolts and washer.
②
Wiring diagram is shown inside protection cover.
Single-phase specifications
You can change to a 100V or 200V connection by changing terminal plate (2pcs.).
※
※
※
※
It is wired to 200V when delivered to you.
If you want to change to a 100V connection, remove M4 nut of electric source
terminal and change terminal plate as illustrated below.
Insert electric source cord through cable-gland on the right side of terminal box.
Three-phase specifications
You can change to a 200V or 400V connection by changing terminal plate (3pcs.).
※
※
※
※
It is wired to 200V when delivered to you.
If you want to change to a 400V connection, remove M4 nut of electric source
terminal and change terminal plate as illustrated below.
Insert electric source cord through cable-gland on the bottom side of terminal box.
Connect each phase L1-L2-L3 to each electric source terminal respectively in
accordance with the below wiring diagram.
Terminal plate
Terminal Block
Electric Source
Terminal M4 Nut
Ground Terminal
M5 Bolt
200V Connection
(When delivered to you)
400V Connection