DISTURBANCES DURING OPERATION 

 

Fault 

Reason 

Remedy 

 
Pulsation 
 

1.  Air penetrates between the nozzle and its 
tapered seat in the body. 
2.  Air is drawn in through head seal. 

1.  Unscrew the nozzle in order to clean the 
seat – replace if damaged. 
2.  Seal the head. 

 
Crescent 
 

1.  Lacquer residues inside the head, partially 
clogged head holes. Different air pressure in 
both nozzles. 

1.  Remove soiling from nozzles and head. 
Do not use metal objects to do this. 

 
Skew 
 

1.  Lacquer residues on nozzle hole edges, 
or damaged central hole in the head. 
2.  Loose nozzle. 

1.  Remove soiling from the nozzle or replace 
it if damaged. 
2.  Unscrew the nozzle and clean its seat. 

 
Splitting 
 

1.  Too low lacquer viscosity. 
 
2.  Too high liquid outflow. 

1.  Add more lacquer in order to increase 
viscosity.  
2.  Adjustment with jet or needle control knob. 

 
Separate stains 
 

1.  Too low lacquer viscosity. 
 
2.  Too high liquid outflow. 

1.  Reduce lacquer viscosity. 
 
2.  Increase liquid outflow. 

 
 
Spitting 
 

1.  Nozzle and needle are incorrectly 
mounted. 
2.  Too short stroke of release trigger 
opening air flow. 
3.  Lacquer residues inside the head. 

1.  Clean or replace nozzle and needle. 
 
2.  Replace air valve unit. 
 
3.  Clean the head. 

 
 

PROBLEMS AND TROUBLESHOOTING 

 
Problem 

Location 

Parts to check 

Reason 

Solution 

Press 
down 

Adjust 

Clean 

Replace 

 
Air leak from head 
hole 

 
Air  
valve 

Air valve 

Dirty or soiled seat 

 

 

Air valve  
seat 

Soiled or damaged 

 

 

Worn out valve spring 

 

 

 

Valve sealing 

Damaged or aged 

 

 

 

 
 
 
 
Lacquer leaks 

 
 
 
 
Spray gun nozzle 
hole 

Nozzle - needle unit 

Soiled, damaged,  
seat wear 

 

 

Loose needle knob 

 

 

 

Worn out needle spring 

 

 

 

Nozzle - body 

Insufficiently tightened 

 

 

 

Soiled or damaged seat 

 

 

Needle seal 

Needle does not return to 
closed position - seal too 
tight 

 

 

Needle does not return to 
closed position - lacquer 
residues on the needle 

 

 

Needle  
seal 

Needle seal  
needle unit 

Wear 

 

 

Seal 

Insufficient pressing down 

 

 

 

Lacquer does not 
flow out 

 
Nozzle hole 

Needle knob 

Insufficient opening 

 

 

 

Nozzle hole 

Clogged 

 

 

 

Lacquer filter 

Clogged 

 

 

 
 
 
 
 

 
 
 

 

 

 

 

 