1.2 

 Personal Safety 

Personal Requirements 

People who plan to install or maintain battery equipment must be trained, 
understood all necessary safety precautions, and are able to perform all operations 
correctly. 

Only qualified professionals or trained people are allowed to install, operate, and 
maintain the equipment. 

 

Personal Safety 

 

 

Do not place battery at a children or pet touchable area. 

 

Do not touch the energized battery, as the enclosure is hot. 

 

Do not touch the energized battery terminals. 

 

Do not stand on, lean on, or sit on the battery. 

 

1.3 

 Electrical Safety 

Symbols on battery 

There are some electrical symbols on battery relate to electrical safety. Please 
make sure you have fully understand them before installation

 

Electrical danger 

Voltage exits when the battery is 

powered on. Only qualified engineers are 

allowed to operate. 

 

Earth connector 

Earth connection. 

 

DC positive and 

negative connectors 

Identify positive and negative connectors 

of DC power source. 

 

CE mark 

The product meets CE certification. 

 

WEEE tag 

Can't leave battery as garbage disposal. 

 

Recycle 

Battery can be recycled. 

 

Web: marketing-anern.com | Email: [email protected] | Whatsapp: +86 13058030989

Summary of Contents for N POWERWALL 2.0

Page 1: ...N POWERWALL 2 0 LFP Battery Series User Manual Web marketing anern com Email marketing anern com Whatsapp 86 13058030989...

Page 2: ...Product Information 5 2 1 Battery Overview 5 2 2 Appearance 6 2 3 Dimensions 6 2 4 Capacity Options 7 2 5 Display 8 2 6 Operation 8 2 7 Multiple Batteries Parallel Connection 10 3 Specifications 11 3...

Page 3: ...ized information to avoid personal injury and property damage Relative safety symbols have been listed below DANGER indicates a hazardous situation which if not avoided will result in serious injury a...

Page 4: ...ry terminals Do not stand on lean on or sit on the battery 1 3 Electrical Safety Symbols on battery There are some electrical symbols on battery relate to electrical safety Please make sure you have f...

Page 5: ...operation Recharge battery in every six months Recharge battery within 10 days after battery is fully discharged Please engage greater than or equal to two batteries when maximum charge current is mor...

Page 6: ...mable or explosive gas or smoke Do not perform any operation on the equipment in such environments The operation and service life of the battery depends on the operating temperature Operate the batter...

Page 7: ...the requirements of the inverter controller It is mainly for home energy storage system Features LiFePO4 prismatic cell 6000 cycles 0 5C conditions Maximum 1C charge and discharge capability Wall mou...

Page 8: ...e terminal Negative terminal Battery parallel communication port Inverter communication port Dial the code switch Operating area The power switch 2 3 Dimensions 2 2 Appearance Web marketing anern com...

Page 9: ...d energy kWh The maximum power kW is limited by main cables from master battery to inverter The maximum 16 battery packs can be parallelly communicated For example ONE PACK is 4 8kWh 4 8kWh 9 6kWh 19...

Page 10: ...ion Power Switch ON OFF To power on the whole battery system no power output Power Connector There are two sets of power connectors in the operation area as shown in the figure the one on the left is...

Page 11: ...load and the baud rate is 2400bps RS232 upload communication interface It can communicate with the host computer through the RS232 communication interface INVCOM pin interface definition BATCOM The BM...

Page 12: ...dress switch settings 2 7 Multiple Batteries Parallel Connection Please set dip address switches as above Please see communication ports link connection below Please see power parallel connection belo...

Page 13: ...l 2 8V 3 60V Working Temperature Charge 0 55 Discharge 20 60 Storage Temperature 10 35 Nominal Capacity kWh 2 56kWh 5 12kWh Max Charge Current A 70A 100A Max Discharge Current A 75A 100A Cycle Life 60...

Page 14: ...2 8V 3 6V Working Temperature Charge 0 55 Discharge 20 60 Storage Temperature 10 35 Nominal Capacity kWh 4 8kWh Max Charge Current A 75A Max Discharge Current A 75A Cycle Life 6000 25 0 5C 85 DOD SOC...

Reviews: