INSTALLATION
SECTION 3
ELECTRICAL
SUPPLY
18
Fig. 8.
2
M
L1
X2
V1
220/240V
50Hz
Time Clock and/or
Switch if fitted
220/240V
50Hz
Stat 82o (max)
Limit 93o C
Brown
Black
TLSC stat
TC2 stat
TLSC thermostat
N
T1 T2 S3 B4
T
PE
X1
3
1
10
9
8
6
4
11 12
L1
N
AL H1
N
L
L
L
N
N
N
N
T1 T2 S3 B4
Key to diagram
M
Motor
PE
Photocell
T
Ignition transformer
V1
Oil Valve
X1
LMO/LOA 2.. control
X2
7 pole connector
H1
Remote burner run signal
AL
Remote lockout signal
Wiring external to the water heater must be installed in accordance with the I.E.E.
Regulations for the wiring of buildings and to any local regulations that may apply.
The heaters are designed to run off 220/240V 1 Ph 50 Hz supply and the fuse rating is
5 Amp See pages 4 & 5.
The method of connection to the mains electricity supply should facilitate complete
electrical isolation of the appliance preferably by use of an unswitched shuttered socket
outlet in conjunction with a fused three pin plug both complying with the requirements
of BS 1363/A.
Alternatively, a fused double pole switch of fused spur box serving only the heater may
be used.
The point of connection to the mains should be readily accessible and adjacent to the
appliance.
Connect electrical supply to the harness plug/socket (see Fig. 8 Wiring Diagram) Mains
input cable should be connected to the mains supply as detailed above.