4
Checklist (if purchased through Heatrae Sadia)
Before commencing installation check that all the components for your Andrews Flexistor unit are
contained in the package. The following components are supplied as standard with your Andrews
Flexistor unit:
Commercial Cylinder Vol-
ume (ltr)
Pressure Reducing Valve
Pressure Relief Valve
Single Check
Valve
400 - 500
1” Integrated inlet control valve
800
1.25” (1.5 - 6 bar) or (5 -10 bar)
1” x 1.25” (8 bar) or (13 bar)
1.25”
1000
1.25” (1.5 - 6 bar) or (5 -10 bar)
1” x 1.25” (8 bar) or (13 bar)
1.25”
1250 - 1450
1.5” (1.5 - 6 bar) or (5 -10 bar)
1” x 1.25” (8 bar) or (13 bar)
1.5”
2000 - 2500
2” (1.5 - 6 bar) or (5 -10 bar)
1.25” x 1.5” (8 bar) or (13 bar)
2”
Table 1: Cold Water Inlet Control Kit (depending on model)
Commercial Cylinder
Volume (ltr)
Expansion Vessel
Size (ltr)
Mounting Kit
Weights
400 - 500
60
Floor Mounted
12kg
800
100
Floor Mounted
17kg
1000 - 1250
150
Floor Mounted
24kg
1450
200
Floor Mouinted
38.5kg
2000 - 2500
300
Floor Mounted
41kg
Table 2: Expansion Vessel Sizing
•
Factory fitted Temperature & Pressure Relief Valve, set at 90ºC / 1 MPa (10bar) or factory fit
-
ted Temperature & Pressure Relief valve set at 90ºC / 1.5MPa (15bar) Depending on model.
Connection size 1 1/4”BSP male to cylinder and 1 1/4” BSP female outlet.
• Tundish 1 1/4” inlet, 1 1/2” outlet
• Isolating Valve (2”)
• 1” Drain Valve.
• All connections BSP female.
Notes:
1” Integrated inlet control valve is not assembled.