andrews ET 21 Operating Instructions  & Safety Manual Download Page 2

Operating Instructions - 

ET 21 & 25

Click

 www.andrews-sykes.com 

or Call Us Free

 0800 211 611

Control Panel Functions

1.  

Power:

 Use to power On / Off/.

2. 

▲▼

Raises or lowers temperature and / or sleep (off) time.

3.  

Cool: 

Use to select cooling mode.

4. 

 Lower Mode: 

Controls fan low speed.

5.  

High Mode: 

Controls fan high speed.

6.   

Off Timer: 

To set the length of time, once turned on, that you wish the cooler to 

run for. You can set 0~24 hours. Time intervals are 30mins. up to 10 hours and 
then 1 hour between 10 and 24 hours.

7.  

 Remote: 

From the long distance, you can control the machine by wired remote 

control.

8.   

Room: 

If the LED in ON, the displayed temperature is for room temperature. If 

the LED if OFF, the displayed temperature is for spot temperature.

9.  

Comp: 

When the compressor is operating, the LED in ON.

10.  

 Error: 

Error signal (E1: High pressure, E2: Low pressure, E3: Sensor, AF: Eva 

freezing) 

11.   

Water Full: 

Red light indicates ‘Tank Full’. The compressor will shut off 

automatically. Empty tank and replace in position to resume operation. Fig. 2

12.   

Align Drain Tank: 

The red light indicates the water tank is not in the correct 

position.

13.   

Display: 

Display Room / Spot temperature, and the setting temp and sleep 

time in case of setting them. When the user set the sleep timer ‘hr’ will be 
turned on. (Display of ‘LO’: under the 0ºC, display of ‘HI’: over the 50ºC)

   START BY PRESSING THE ‘POWER’ BUTTON. 

•  Cooler will start up automatically 
•  To STOP the unit, press the ‘POWER’ button once again

  To change fan speed, press the ‘LOW’ button.

   If you wish to operate on fan only, press the ‘COOL’ button. To resume 

cooling, press the ‘COOL’ button again. (NOTE: There is a 3 minute delay 
when switching functions to protect the compressor)

   To reduce the temperature of the entire room then select ‘Room / Area 

cooling’. For targeted cooling of machinery, servers, or people etc, select 
‘spot cooling’.

   If you want to display room temperature, push cool and 

 button 

simultaneously for three seconds.

   If you want to switch from centigrade to fahrenheit - push (up) 

 and (down) 

 button simultaneously for three seconds.

Control Panel Functions

   When the power is on, the best set temperature is displayed. Default of set 

temperature is 5ºC.

   When you push either (up) 

 or (down) 

 button, the setting temperature 

can be changed.

   The display showing the set temperature will blink 3 times.

  Limits of Room / Spot and setting temperature:

Room / spot temperature

Setting temperature

0ºC - 5ºC

1ºC - 30ºC

Cooling operates when room / spot temperature is more than set temperature 
Cooling stops when room / spot temperature is less than set temperature  

Setting the timer

   When cooler is operating, press the ‘OFF TIMER’ button and set the length 

of time you want by pressing 

 or 

. Each time you press the button you 

will increase the 'time to off' period by 30 minutes up to 10 hours, and 1 hour 
thereafter up to 24 hours. The display will show .5 for 30 minutes and 1 for 
an hour. e.g. 1 ½ hours will be shown as 1.5.

   When you have finished setting the time period, the 'off timer' lamp will 

illuminate, which indicates the cooler is in sleep (off timer) mode.

   If you press the 'OFF TIMER' button during its operation, the remaining time 

will be shown.

   to CANCEL timing, press the 'OFF TIMER'  button for ONE second, it will 

then switch the timer off automatically.

Errors and Warnings

   WATER FULL - Display shows FU 

When the water container is full, FU is displayed and the LED 'Water full' 
illuminate.

   ALIGN WATER TANK -  

If the water tank is not positioned correctly, the LED 'Align Drain Tank' 
illuminate

   HIGH PRESSURE -  

'E1' is displayed and the 'Error' LED will be on when the pressure of the 
compressor is too high and the high pressure switch is open.

   LOW PRESSURE -  

'E2' is displayed and the 'Error' LED will be on when the pressure of the 
compressor is too low.

   SENSOR PRESSURE -  

If the thermistor is short circuited or cut, 'E3' is displayed and the 'error' LED 
will be on

   ANTI FREEZING -  

When the temperature of the evaporator is below -4ºC, 'AF' is displayed and 
the 'Error' LED will be on. 

FLEXIBLE DUCT OUTLET (COLD AIR)

HANDLE

DIGITAL CONTROLLER

CONDENSER OUTLET (HOT AIR)

EVAPORATOR FILTER

AMBIENT AIR INTAKE.

CONDENSER FILTER

CASTERS (FRONT LOCKABLE)

ELECTRIC PANEL

(ACCESS BY AUTHORISED SERVICE

PERSONNEL ONLY)

POWER PLUG

WATER LEVEL INDICATOR

TO CHECK WATER LEVEL OF THE

CONDENSATE TANK.

CONDENSED WATER TANK

TO COLLECT WATER GENERATED 

DURING COOLING.

Errors and Warnings

Front View

Rear View