Care of your Double Cool Dx

   Do not add any chemicals, bleaches or agents to the water tank other than 

sterilising tablets.

   Do not place anything on top of the unit and don’t obstruct the air vents. 

   Do not remove the repositions the unit with water in the tank.

   Do not remove any access panels when the unit is switched ON.

   Always operate, transport and store the Double Cool Dx in an upright position.

   Always inspect the unit before and use at regular intervals. If the unit is 

damaged, do not use it. Have all necessary repairs carried out by an 
authorised repair agent.

   When not in use, store the unit with all controls set to OFF and with the water 

thank fully drained, cleaned and sterilised

Setting up your Double Cool Dx

The DOUBLE COOL Dx model is designed to be placed on the base trolley 
supplied and must be kept level to prevent over spill from the water tank. Place the 
DOUBLE COOL Dx squarely onto the base trolley. Please note that the trolley is not 
attached to the unit

To cool a room efficiently the DOUBLE COOL Dx requires a continuous supply of 
fresh air and therefore should be positioned close to an open window or door to the 
outside. It is also important to have another window or a door open for the warm 
air to exit. Once positioned in the room, lock the casters to prevent the unit from 
moving. Decide upon which method is best suited for filling the water tank. 

There are two options, either direct filling by connections to a main water supply or 
by manual filling via the manual water fill inlet.

Direct Filling

Attach a suitable hose to the auto fill water inlet connector using a worm drive clip. 
Double check for sign of water leakage from the connection before connecting the 
unit to the power supply. If in doubt, consult a qualified plumber.

There is a float valve inside the water tank, which controls the water flow as 
necessary.

Manual Filling

CAUTION. Always switch OFF the unit and unplug from the power supply before 
manually filling this machine. Mop up all the spillages before switching ON again.

Never handle plugs and electrical switches with wet hands.

To fill the water tank, open the manual water fill inlet and our up to 45 liters of fresh 
clean water into the the tank. 

The level of water in the tank is displayed on the water level indicator. During use, 
the water level should be checked on a regular basis and topped up as necessary. 
Never overfill this machine. DOUBLE COOL Dx is now ready to use.

Controls

   With the unit in position and the water tank either filled manually or connected 

to a main water supply, plug the unit into a suitable power supply and switch 
the supply ON.

   The unit can be operated as a cooler or simply as a fan.

      To operate as a fan, full raise the water flow lever then turn the ON/OFF/FAN 

switch to the required fan speed setting. 

   There are three fan speeds available Low, Medium or High. When first 

switching ON, select Low and wait for the fan to reach normal running speed.

  There are two controls for the direction of airflow. 

   The air flow up/ down control lever is a manual control which directs the air 

flow vertically.

   The air deflector control is a powered deflectors, which oscillates Horizontally 

(side to side). When switched ON the deflectors move from left to right in a 
sweeping motion, distributing air to a wider area. 

   If the air flow is required in one direction only, switch the vertical louver swing 

control to ON and when the air flow is the right direction, switch the vertical 
louver swing control OFF.

   To run the unit in cool mode, operated the unit as described above and then 

depres the water flow lever.

   When switching the unit OFF, full press down the water flow lever and allow 

the fan to run for approximately 10 minutes.

This enables the cooling pads to dry and will help eliminate the possibility of a 
musty odor from the unit when next used.

1. Water flow knob (Cool Knob)
2. Air flow up / down control knob
3. Ar outlet grill
4. Power supply cable
5. ON/OFF and Fan speed control
6.  Vertical Louver swing control
7. Auto fill water inlet (Float valve)

8. Water level indicator
9. Manual water fill inlet
10. Stand
11. Water tank reservoir
12. Drain plug
13. Holder pad
14. Power Indicator

Reviews: