The MCPA must be installed into a shelf that provides fan-cooling.  The MCPA requires 
+24VDC with a current handling capacity of up to 12.4A.  An RS-485 interface is 
provided and must be utilized to configure the PA for operation and monitoring of alarms 
and status.  RF cables connect from a radio source to the SMA-type input; from the N-
type output to a filter-duplexer module. 

 

FCC Statements: 

 

FCC ID S8L-100978MCPA 

 

This device complies with Part 2, 15 & 24 of the FCC Rules. Operation is subject to the 
following two conditions: (1) this device may not cause harmful interference and (2) this 
device must accept any interference received, including interference that may cause 
undesired operation. 

 

Warning  

Changes of modifications not expressly approved by the manufacturer could void the 
user’s authority to operate the equipment. 

Summary of Contents for RF100978

Page 1: ...ew Corporation Proprietary Use pursuant to Company Instruction 1 of 8 1960 CDMA Multiple Carrier Power Amplifier Model RF100978 Operation Instruction Date Mar 19 2008 Version 1 1 Ref FCC ID S8L 100978...

Page 2: ...multiple carriers to a composite power level of 75 Watts MCPA Specifications The RF100978 provides linear amplification of multi carrier signals in the CDMA frequency band The specifications are Param...

Page 3: ...e which can range from 18V to 30V The DC power is brought into the amplifier through a D Sub connector located on the front faceplate of the amplifier A second D Sub connector located on the amplifier...

Page 4: ...Andrew Corporation Proprietary Use pursuant to Company Instruction 4 of 8 Figure 1 RF100978 MCPA Front Panel Figure 2 RF100978 MCPA Back Panel Figure 3 RF100978 MCPA Top Bottom Panels...

Page 5: ...Andrew Corporation Proprietary Use pursuant to Company Instruction 5 of 8 Figure 4 RF100978 MCPA Side Panels...

Page 6: ...ning Green High DC power consumption Minor High DC Power Consumption Warning Green Partial Main Amp Failure Minor Partial failure within RF chain RF output is backed off Green Temperature Overload Maj...

Page 7: ...o Controller 5 GND_Presence_Reset Ground 6 Reserved Not allowed for the MCPA 7 GND Ground 8 Reserved Not allowed for the MCPA 9 Reserved Not allowed for the MCPA 10 GND Ground 11 Reserved Not allowed...

Page 8: ...status RF cables connect from a radio source to the SMA type input from the N type output to a filter duplexer module FCC Statements FCC ID S8L 100978MCPA This device complies with Part 2 15 24 of th...

Reviews: