MAINTENANCE 

 

1. 

 

Do not drop this monitor or subject it to strong impact. 

2. 

 

Avoid high temperature and solarization. Do not immerse the monitor in water as this 

will result in damage to the monitor. 

3. 

If  this  monitor  is  stored  near  freezing,  allow  it  to  acclimate  to  room  temperature  before 

use. 

4. 

The monitor  requires  6  hours  to  warm from  the minimum  storage  temperature  between 

uses until the monitor is ready for its INTENDED USE when the ambient temperature is 

20 °C. 

5. 

The  monitor  requires  6  hours  to  cool  from  the  maximum  storage  temperature  between 

uses until the the monitor is ready for its INTENDED USE when the ambient temperature 

is 20 °C

.

 

6. 

 

Do not attempt to disassemble this monitor. 

7. 

If you do not use the monitor for a long time, please remove the batteries. 

8. 

It  is  recommended  the  performance  should  be  checked  every  2  years  or  after  repair. 

Please contact the service center. 

9. 

Clean the monitor with a dry, soft cloth or a soft cloth squeezed well after moistened with 

water, diluted disinfectant alcohol, or diluted detergent. 

10.  No  component  can  be  maintained  by  user  in  the  monitor.  The  circuit  diagrams, 

component part lists, descriptions, calibration instructions, or other information which will 

assist  the  user

’s  appropriately  qualified  technical  personnel  to  repair  those  parts  of 

equipment which are designated repairably can be supplied. 

11.  The  monitor  can  maintain  the  safety  and  performance  characteristics  for  a  minimum  of 

10,000  measurements  or  three  years,  and  the  cuff  integrity  is  maintained  after  1,000 

open

–close cycles of the closure. 

12.  It  is  recommended  the  cuff  should  be  disinfected  2  times  every  week  if  needed  (For 

example, in hospital or in clinique). Wipe the inner side (the side contacts skin) of the cuff 

by a soft cloth squeezed after moistened with Ethyl alcohol (75-90%), then dry the cuff by 

airing. 

13.  Not servicing/maintenance while the monitor is in use

.

 

 

EXPLANATION OF SYMBOLS ON UNIT 

 

  Symbol for

” THE OPERATION GUIDE MUST BE READ”(The sign background colour: 

blue.The sign graphical symbol: white)   

   

Symbol for 

“WARNING” 

      Symbol for 

“TYPE BF APPLIED PARTS” (The cuff is type BF applied part) 

Summary of Contents for KD-752

Page 1: ...DN KD 752 SMSY01 V1 0 Operation Guide History Revision NO Revision date Revision Description Versi on Drafter Approver 01 2018 10 25 Originated V1 0 Zhang RuoShang Zhang Fei...

Page 2: ...D 752 SMSY01 V1 0 Operation Guide Operation Guide V1 0 Product project name Wireless Blood Pressure Monitor Model name KD 752 Project number 2017 007 XY13 Drafted by Date Reviewed by Date Approved by...

Page 3: ...PROCEDURES 6 1 BATTERY LOADING 6 2 CLOCK AND DATE ADJUSTMENT 7 3 VOICE SETTING 8 4 CONNECTING THE CUFF TO THE MONITOR 9 5 APPLYING THE CUFF 9 6 BODY POSTURE DURING MEASUREMENT 10 7 TAKING YOUR BLOOD P...

Page 4: ...value usually appears in the daytime and lowest one usually at midnight Typically the value begins to increase at around 3 00 AM and reaches to highest level in the daytime while most people are awake...

Page 5: ...od pressure and pulse rate The most recent 4 60 measurements can be stored in the memory with date and time stamp The Electronic Sphygmomanometer corresponds to the below standards IEC 60601 1Edition...

Page 6: ...m More than 60 incl 5 12 Environmental temperature for operation 10 40 50 104 13 Environmental humidity for operation 85 RH 14 Environmental temperature for storage and transport 20 50 4 122 15 Enviro...

Page 7: ...please see part ELECTROMAGNETIC COMPATIBILITY INFORMATION It is suggested that the wireless blood pressure monitor be kept 10 meters away from other wireless devices such as WLAN unit cell phone micr...

Page 8: ...2 Consult your physician before using the device for any of the following conditions common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation arterial sclerosis poor per...

Page 9: ...OCK AND DATE ADJUSTMENT a Once you install the battery it will enter Clock Mode and LCD will display time and date See picture 2 1 The monitor will enter Standby Mode after 10 seconds with no operatio...

Page 10: ...00 12 00 PM 1 00 1 00 AM 13 00 1 00 PM 2 00 2 00 AM 14 00 2 00 PM 3 00 3 00 AM 15 00 3 00 PM 4 00 4 00 AM 16 00 4 00 PM 5 00 5 00 AM 17 00 5 00 PM 6 00 6 00 AM 18 00 6 00 PM 7 00 7 00 AM 19 00 7 00 PM...

Page 11: ...ttached to the monitor when it is packaged Should the cuff become unattached align the two plugs and four brackets of the cuff with the plug sockets and bracket sockets of the monitor and press the cu...

Page 12: ...more reliable than that from only one measurement Slide the standard multiple switch on the right side of the monitor toward to 1 to select standard mode and toward to MULT to select multiple mode be...

Page 13: ...peration Alternatively you can press the START button to turn off the monitor manually e The measurement result will be shown after multiple measurements The individual results will not be displayed f...

Page 14: ...no result which is measured from 18 o clock to 20 o clock in last 7 days stored in the current user memory zone the LCD will display 0 See picture 8 9 f Press MEM button again the most recent result w...

Page 15: ...o operation You can also press the START button to turn off the monitor manually 10 DELETING MEASUREMENTS FROM THE MEMORY When any result is displaying exclude average value displaying keeping on pres...

Page 16: ...d Apply the cuff correctly and try again Body posture was not correct during testing Review the BODY POSTURE DURING MEASUREMENT sections of the instructions and re test Speaking arm or body movement a...

Page 17: ...sure sensor parameter error No response when you press button or load battery Incorrect operation or strong electromagnetic interference Take out batteries for five minutes and then reinstall all batt...

Page 18: ...soft cloth squeezed well after moistened with water diluted disinfectant alcohol or diluted detergent 10 No component can be maintained by user in the monitor The circuit diagrams component part lists...

Page 19: ...INFORMATION Only charge the cost of components and transport SERVICE CENTER ANDON HEALTH CO LTD No 3 Jinping Street YaAn Road Nankai District Tianjin 300190 China Tel 86 22 60526081 iHealthLabs Europ...

Page 20: ...magnetic environment RF emissions CISPR 11 Group 1 Class B Home healthcare environment Harmonic distortion IEC 61000 3 2 Class A Home healthcare environment Voltage fluctuations and flicker IEC 61000...

Page 21: ...ide 19 19 810 800 960 Pulse modulation 18Hz 28V m 870 930 1720 1700 1990 Pulse modulation 217Hz 28V m 1845 1970 2450 2400 2570 Pulse modulation 217Hz 28V m 5240 5100 5800 Pulse modulation 217Hz 9V m 5...

Reviews: