background image

8

9

1. Appliance

The VARROX

®

-Vaporiser consists of a heater, a metallic-

support and 3 m of cable with 2 battery-clips. It has an 

output of 150 W. The power source can be an accumu-

lator (car battery, 12 volt, 12 ampere, capacity > 40 Ah).

2. Mode of action

Oxalic acid dihydrate is added to the pan, then the ap-

pliance is inserted through the entrance of the hive. As a 

result of the heating action of the pan, the oxalic acid lique-

fies and vaporises. Oxalic acid vapour fills the hive and all 

the bees and surfaces are then covered with a very thin la-

yer of oxalic acid crystals. These fine crystals are tolerated 

well by the bees, but have a deadly effect on varroa mites.

3. Treatment

3.1 Time

The use of the VARROX

®

-Vaporiser is particularly suita-

ble for the follow up treatment in 

broodless colonies

 (see  

5. Concept of control).

The treatment should not be made during heavy bee flight. 

The temperature should not be below + 4 °C

. Especial-

ly in honeydew areas the last cleansing flight should not 

date back more than four weeks. A cleansing flight should 

then be awaited.

3.2 Dosage

*One spoon filled loose and without pressing, corresponds to 

one gram Oxalic acid-dihydrate. Each VARROX

®

-Vaporiser 

is supplied with a measuring spoon.

3.3 Placing the VARROX

®

-Vaporiser

The appropriate amount of oxalic acid-dihydrate is placed

into the VARROX

®

-Vaporiser. Afterwards, the appliance

is inserted 

through the entrance of the hive right below 

the cluster of the bees

 until the metallic support is fully 

inside. It must not be used at close range of wax or bees 

(minimum distance 2 cm).

If the insertion through the entrance is not possible becau-

se of the construction of the hive, use the opening of the 

diagnosis drawer where possible. 

Attention:

 The VARROX

®

-Vaporiser reaches temperatures 

of up to 400°C. It can create patches of heat on the hive 

bottom and frames if used for too long or too close to 

the hive. This can be avoided by using a sheet metal or 

wooden board below the pan.

Caution with synthetic hives and plastified varroa 

screens: 

With hives or varroa screens made of synthetic 

material, an isolation platter (minimum 4 mm thick) must 

be put under the appliance.

Hint: 

Depending on the height of the entrance and the 

bottom of the hive, we recommend that the VARROX

®

-

Vaporiser is fitted in evenly by bending down both sides 

of the metallic support a few millimetres. The distance 

between the bottom of the hive and the heating element 

can be increased and the source of the heat is taken off 

the bottom.

3.4 Sealing up the hive

Seal the whole entrance (or diagnosis drawer) around the 

handle of the VARROX

®

-Vaporiser using strips of foam or 

cloth. Open floors or other openings should be shut tightly 

over the whole surface.

3.5 Duration of the treatment

After the hive is sealed up, the vaporiser should be con-

nected to a car battery (12 V) for 

2

1/2

 minutes

One of the battery-clips of the cable can be constantly 

connected with the source of power using the contact 

of the second clip to switch the appliance on and off. It 

makes no difference which clip is connected to the plus-

terminal - the function of the heating is not reduced.

After disconnecting

 the VARROX

®

-Vaporiser, 

wait for 2 

minutes

 before the appliance is pulled out, so that the 

oxalic acid-vapour can settle. Once removed, ensure that 

the entrance of the hive is shut tightly again and is 

left 

shut for another 10 minutes

After taking out the VARROX

®

-Vaporiser, it should be 

cooled in a bucket of water, so that with the next use, no 

vaporisation begins before the appliance is inserted into 

the hive.

4. Oxalic acid-dihydrate (Oxalic acid-crystals)

Oxalic acid is an unhealthy, toxic and corrosive substance.

When filling the VARROX

®

-Vaporiser and during the treat-

ment, it is absolutely necessary to 

wear protective glasses, 

a protective mask FFP3, gloves and long-sleeved clothes

.

4.1 Purchase of oxalic acid-dihydrate

For the treatment, oxalic acid-dihydrate (C2H2O4 x 2 

H2O) CAS-No. 6153-56-6, EG-No. 205-634-3 has to 

be used.

Normally available in pharmacies.

4.2 Purchase of oxalic acid-dihydrate/Handling of 

 

oxalic acid

Oxalic acid can cause damage to health with both skin 

contact and if swallowed. Avoid contact with eyes and 

skin. Vapours and dusts of the oxalic acid should not be 

inhaled. Keep oxalic acid out of the reach of children. 

Oxalic acid must be stored in its original container (with 

law-concurring labelling) in a safe place. In the case of 

eye contact, immediately wash the acid out with water. If 

ingested consult a physician immediately.

Working safety during and after the treatment

•  With treatments of apiaries in the open, take care that 

the wind blows any escaping oxalic acid away from 

the user. The whole length of the cable should be used 

and the user should stay away from the hive.

•  The foam material used for sealing the hive must be 

handled with gloves. This avoids contact with the acid 

where it may have condensed on the inner side of 

the foam. The foam material must be washed out  

carefully with water before putting away.

•  

Treatments on colonies in a beehouse must only be 

made from outside through the entrances of the hi-

ves

. During the treatment, the beehouse must be well 

ventilated. No person must be inside the beehouse.

•  The VARROX

®

-Vaporiser is a powerful heater that ge-

nerates high temperatures. The vaporiser must not be 

used near easily flammable materials. Always put the 

vaporiser on a sheet of non-flammable material (i.e. 

metal). Never touch the metallic part of the vaporiser 

when in use. Caution: metallic parts may be hot for 

a long time after use. The vaporiser must never be 

switched on without supervision.

•  After the treatment in the winter, oxalic acid-crystals 

are found on the bottom of the hive. This can be due 

to the absence of bee cleaning activity as found in 

the summer. Caution is therefore needed if mite fall is

controlled after a treatment in the winter. Gloves and 

a protective mask should be worn. The rest of the oxa-

lic acid will break down to water and carbon dioxide 

and will be cleaned by the bees in spring.

5. Concept of control

Do not treat colonies with honey supers on.

5.1 Treatment in brood free colonies

The VARROX

®

 -Vaporiser can be used in broodless colo-

nies. With the VARROX

®

 -Vaporiser a very good efficacy

of > 96 % can be reached and thus it can decimate the 

varroa-mite-population reliably to a very low level. The-

reby, optimal conditions for the new season are created 

for the bees.

If there is a mite fall of more than 1000 varroa mites 

caused by the treatment, or if it is uncertain whether there 

was brood in the colonies, a second treatment is recom-

mended. The optimal time for it, is two weeks after the first 

treatment. If a second treatment is necessary only 1 gram 

of oxalic acid has to be used, independent on the size of 

the hive. Two or more treatments are very well tolerated 

by the bees.

5.2 Treatment of swarms / artificial swarms

Swarms and artificial swarms can be treated at any time.

5.3 Treatment of nucleus

Treatment of queenright nuclei should be carried out be-

fore the first brood is sealed, if possible. (No efficacy in 

sealed brood).

English

English

Attention:

 Queenless colonies react very conspicuously to 

the treatment with an increased activity in the hive and by 

leaving the hive.

6. Accessories 

(to order separately)

•  Protective mask FFP3 (Acid / Gas respirator)

•  Timer

•  Gloves

•  Glasses

7. Electrical supply

The VARROX

®

-vaporiser must be operated with 12 volts, 

12 ampere and cannot be directly plugged into a socket 

of 110 V or 220 V. It runs on 

alternating and direct cur-

rent 

(AC/DC). The following can be used as a source of 

power:

•  Car accumulator minimum 40 Ah

 (the accumula-

tor and battery charger can be bought in DIY super 

stores)

•  With a transformer (12 V, 12 A)

If the vaporiser is connected to the car accumulator for 

prolonged periods the engine of the car may have to be 

run to avoid draining the battery.

8. Source of troubles

•  After the treatment there is still some acid left in the-

pan

•  Heating time is too short: Heat longer (plus 

about 1/2 minutes)!

•  Accumulator is weak and delivers not enough 

current: Charge accumulator!

•  Possible burr-comb below the frames, has to be re-

moved, so that it is not in the way of the VARROX

®

-

vaporiser or too close. 

•  The treatment should only be used in hives normally 

occupied with bees. Very small colonies or even  

empty hives should not be treated.

9. Warranty

Please, follow the instructions for use carefully. We do not

assume any warranty for incorrect application, reasons 

of unsatisfactory efficacy or possible damages that are 

beyond the control of Andermatt BioVet AG.

Type hof hive

Oxalic acid-

dihydrate

Measuring 

spoon*

One-chanber-hive 

(warm way, one-storey)

1 g

1

Two-chamber-hive 

(two-storey/Dadant)

2 g

2

Summary of Contents for VARROX

Page 1: ...ormation stand Actualizaci n Oktober 2015 Octobre 2015 Ottobre 2015 October 2015 Octubre 2015 IT FR Gebrauchsanleitung zum VARROX Verdampfer Mode d emploi pour le vaporateur VARROX Istruzioni per l us...

Page 2: ...Kontakte mit den Augen und der Haut vermeiden D mpfe und St ube d rfen nicht eingeatmet werden Oxals ure darf nicht in die H nde von Kindern gelangen Oxals ure im Originalbeh lter mit gesetzeskonforme...

Page 3: ...eau ou lors d absorption du produit Evitez tout contact avec les yeux et la peau Les vapeurs et poussi res d acide oxa lique ne doivent pas tre inhal es L acide oxalique doit tre hors de port e des en...

Page 4: ...ndo viene ingerito Evitare quindi qualsiasi contatto con gli occhi e la pelle Non inalarne il vapore e la polvere d acido ossalico Tenere al di fuori dalla por tata dei bambini Conservare l acido ossa...

Page 5: ...ed Keep oxalic acid out of the reach of children Oxalic acid must be stored in its original container with law concurring labelling in a safe place In the case of eye contact immediately wash the acid...

Page 6: ...as luego del primer tratamiento Si existiera la necesidad de realizar un segundo tratamiento se debe utilizar solamente un gramo de cido ox lico independientemente del tama o de la colmena El segundo...

Page 7: ...chliessen FR Allumez l instrument pendant exactement 2 minutes une batterie 12V 2A IT Allacciare le pinze alla batteria 12V 12A per esattamente 2 minuti EN Attach the battery clips to a car battery 12...

Reviews: